Product Description

Schneider Electric XPSMP11123 Product overview The Schneider Electric XPSMP11123 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 - Breaking capacity: 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output - Characteristic: Value(s) - Checks: Configuration 10) Configuration 13) Configuration 3) Configuration 4) Configuration 5) Configuration 6) Configuration 9) - Connections - terminals: Captive screw clamp terminals flexible 0.14...0.75 mm² without cable end, 2 wires Captive screw clamp terminals solid 0.14...0.75 mm² without cable end, 2 wires Captive screw clamp terminals flexible 0.14...2.5 mm² without cable end, 1 wire Captive screw clamp terminals solid 0.14...2.5 mm² without cable end, 1 wire Captive screw clamp terminals flexible 0.25...1 mm² with cable end, without bezel, 2 wires Captive screw clamp terminals flexible 0.25...1.5 mm² with cable end, with bezel, 1 wire Captive screw clamp terminals flexible 0.25...2.5 mm² with cable end, without bezel, 1 wire Captive screw clamp terminals flexible 0.5...1.5 mm² with cable end, with double bezel, 2 wires - Function of module: 0 functions disabled (factory setting) 1 emergency stop monitoring 1-channel wiring, category 2 10 enabling grip switch monitoring (3-position switch), category 4 11 sensing mat and edges monitoring, category 3 12 sensing mat and edges monitoring, category 3 13 relay output safety light curtain monitoring, category 4 14 coded magnetic switch monitoring, category 4 15 coded magnetic switch monitoring, category 4 2 emergency stop monitoring 1-channel wiring, category 2 3 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 4 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 5 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 6 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 7 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 8 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 9 guard monitoring for injection presses and blowing machines, category 4 - Input protection type: Internal, electronic - Local signalling: 12 LEDs - Maximum line resistance: 100 Ohm <6561.7 ft (2000 m) - Maximum response time on input open: 30 ms - Minimum output current: 10 mA relay output - Minimum output voltage: 17 V relay output - Number of additional circuits: 3 solid state outputs - Number of safety circuits: 3 NO relays per function (6 NO total), volt-free - Output thermal current: 2 A for 1 output and 4 A for the other 2 outputs relay 3.3 A for all 3 outputs relay simultaneously 6 A for 1 output and 2 A for the other 2 outputs relay - Power Consumption in W: 5 W - Product Certifications: UL CSA BIA - Product or Component Type: Safety controller with pre-defined function - Range of Product: Preventa Safety automation - Safety level: Can reach PL e/category 4 EN/ISO 13849-1 Can reach SIL 3 EN/IEC 62061 - Safety module application: 2 independent functions - Safety module name: XPSMP - Safety use category: Category 4 maximum EN/IEC 60954-1 - Standards: EN/IEC 60947-1 + A11 EN/IEC 60947-5-1 EN/IEC 60204-1 DIN V VDE 801 + A1 - Synchronisation time between inputs: 0.5 s 13) 1.5 s 14) 1.5 s 15) 1.5 s 5) 1.5 s 6) 1.5 s 9) Unlimited 3) Unlimited 4) Unlimited 7) Unlimited 8) - Type of start: Automatic or unmonitored 1) Automatic or unmonitored 10) Automatic or unmonitored 11) Automatic or unmonitored 14) Automatic or unmonitored 3) Automatic or unmonitored 5) Automatic or unmonitored 7) Monitored 12) Monitored 13) Monitored 15) Monitored 2) Monitored 4) Monitored 6) Monitored 8) Monitored 9) - [Ith] conventional free air thermal current: 20 A - [Uc] control circuit voltage: 24 V - [Ui] rated insulation voltage: 300 V 2)EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 - [Uimp] rated impulse withstand voltage: 4 kV III EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 - [Us] Rated Supply Voltage: 24 V DC - 20...20 % Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number XPSMP11123 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
XPSMP11123
Brand
Schneider Electric
Part Number
XPSMP11123
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Checks
Configuration 10) Configuration 13) Configuration 3) Configuration 4) Configuration 5) Configuration 6) Configuration 9)
Packaging
New surplus, never used
Standards
EN/IEC 60947-1 + A11 EN/IEC 60947-5-1 EN/IEC 60204-1 DIN V VDE 801 + A1
Safety level
Can reach PL e/category 4 EN/ISO 13849-1 Can reach SIL 3 EN/IEC 62061
Type of start
Automatic or unmonitored 1) Automatic or unmonitored 10) Automatic or unmonitored 11) Automatic or unmonitored 14) Automatic or unmonitored 3) Automatic or unmonitored 5) Automatic or unmonitored 7) Monitored 12) Monitored 13) Monitored 15) Monitored 2) Monitored 4) Monitored 6) Monitored 8) Monitored 9)
Characteristic
Value(s)
Local signalling
12 LEDs
Range of Product
Preventa Safety automation
Breaking capacity
180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output
Function of module
0 functions disabled (factory setting) 1 emergency stop monitoring 1-channel wiring, category 2 10 enabling grip switch monitoring (3-position switch), category 4 11 sensing mat and edges monitoring, category 3 12 sensing mat and edges monitoring, category 3 13 relay output safety light curtain monitoring, category 4 14 coded magnetic switch monitoring, category 4 15 coded magnetic switch monitoring, category 4 2 emergency stop monitoring 1-channel wiring, category 2 3 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 4 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 5 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 6 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 7 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 8 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 9 guard monitoring for injection presses and blowing machines, category 4
Safety module name
XPSMP
Safety use category
Category 4 maximum EN/IEC 60954-1
Input protection type
Internal, electronic
Associated fuse rating
4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current
10 mA relay output
Minimum output voltage
17 V relay output
Output thermal current
2 A for 1 output and 4 A for the other 2 outputs relay 3.3 A for all 3 outputs relay simultaneously 6 A for 1 output and 2 A for the other 2 outputs relay
Power Consumption in W
5 W
Product Certifications
UL CSA BIA
Connections - terminals
Captive screw clamp terminals flexible 0.14...0.75 mm² without cable end, 2 wires Captive screw clamp terminals solid 0.14...0.75 mm² without cable end, 2 wires Captive screw clamp terminals flexible 0.14...2.5 mm² without cable end, 1 wire Captive screw clamp terminals solid 0.14...2.5 mm² without cable end, 1 wire Captive screw clamp terminals flexible 0.25...1 mm² with cable end, without bezel, 2 wires Captive screw clamp terminals flexible 0.25...1.5 mm² with cable end, with bezel, 1 wire Captive screw clamp terminals flexible 0.25...2.5 mm² with cable end, without bezel, 1 wire Captive screw clamp terminals flexible 0.5...1.5 mm² with cable end, with double bezel, 2 wires
Maximum line resistance
100 Ohm <6561.7 ft (2000 m)
Number of safety circuits
3 NO relays per function (6 NO total), volt-free
Product or Component Type
Safety controller with pre-defined function
Safety module application
2 independent functions
[Us] Rated Supply Voltage
24 V DC - 20...20 %
[Uc] control circuit voltage
24 V
Number of additional circuits
3 solid state outputs
[Ui] rated insulation voltage
300 V 2)EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
Maximum response time on input open
30 ms
Synchronisation time between inputs
0.5 s 13) 1.5 s 14) 1.5 s 15) 1.5 s 5) 1.5 s 6) 1.5 s 9) Unlimited 3) Unlimited 4) Unlimited 7) Unlimited 8)
[Uimp] rated impulse withstand voltage
4 kV III EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
[Ith] conventional free air thermal current
20 A

Compatibility Information

Match XPSMP11123 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing XPSMP11123.

Maintenance Tips

Store XPSMP11123 dry and dust-free in its packaging until installation.