Product Description

Schneider Electric XPSMF4040 Product overview The Schneider Electric XPSMF4040 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Clock: With, supplied by backup capacitor for 1 week following loss of supply - Communication port protocol: Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better Profibus 1 SUB-D 9-pin female, RS485 shielded dual twisted pair cable - Current state 0 guaranteed: <= 1.5 mA discrete input) - Current state 1 guaranteed: 3.5...4.5 mA discrete input) - Discrete I/O number: 24 configurable - Discrete input current: 100 mA - Discrete input voltage: 20 V - Discrete output current: 1 A 140 °F (60 °C) channels 4, 8, 12, 16, 20 and 24) 2 A 122 °F (50 °C) channels 4, 8, 12, 16, 20 and 24) 0.5 A 140 °F (60 °C) channels 1 to 3, 5 to 7, 9 to 11,13 to 15, 17 to 19, 21 to 23) <= 7 A all channels) - Discrete output voltage: 24 V DC - Exchange mode: Half duplex, full duplex, autonegotiation safe Ethernet - Function of module: Monitoring safety actuators discrete output Monitoring safety detection discrete input Monitoring safety dialogue discrete input Monitoring safety dialogue discrete output Monitoring short-circuit and line break line control outputs - Group of channels: 2 groups of 4 line control outputs - Input overvoltage protection: -10…35 V discrete input - Maximum discrete input number: 24 not isolated - Maximum discrete output number: 24 not isolated - Maximum input resistance: 7 kOhm - Maximum leakage current: 1 mA 2 V at state 0 discrete output - Memory description: User logic 250 kB application User logic 250 kB data - Method of access: Slave V0 Profibus - Minimum load: 2 mA per discrete output - No load current: 0.5 A - Nominal output current: 60 mA line control outputs - Number of terminal blocks: 1 power supply 2 line control outputs 6 discrete input/output circuit 8 line control outputs - Operating distance: <= 300 m between station discrete input <= 300 m between station discrete output - Output voltage: 20 V line control outputs - Output voltage tolerance: +/- 2% - Overload protection: Shutdown of outputs concerned with cyclic reconnection - Product or Component Type: Preventa safety PLC compact - Protection Type: 10 A internal fuse - Range of Product: Preventa Safety automation - Response Time: Depending on size of application - Safety module application: F use with numerous machine safety functions and for the protection of personel - Safety module name: XPSMF40 - Safety use category: Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508 - Structure type: 10BASE-T/100BASE-TX, safe Ethernet - Supply: SELV or PELV EN/IEC 60950 - Voltage state 0 guaranteed: <= 24 V discrete input - Voltage state 1 guaranteed: 24...30 V discrete input - [Us] Rated Supply Voltage: 24 V DC - 15...20 % Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number XPSMF4040 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
XPSMF4040
Brand
Schneider Electric
Part Number
XPSMF4040
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Clock
With, supplied by backup capacitor for 1 week following loss of supply
Supply
SELV or PELV EN/IEC 60950
Minimum load
2 mA per discrete output
Exchange mode
Half duplex, full duplex, autonegotiation safe Ethernet
Response Time
Depending on size of application
Characteristic
Value(s)
Output voltage
20 V line control outputs
Structure type
10BASE-T/100BASE-TX, safe Ethernet
No load current
0.5 A
Protection Type
10 A internal fuse
Method of access
Slave V0 Profibus
Range of Product
Preventa Safety automation
Group of channels
2 groups of 4 line control outputs
Function of module
Monitoring safety actuators discrete output Monitoring safety detection discrete input Monitoring safety dialogue discrete input Monitoring safety dialogue discrete output Monitoring short-circuit and line break line control outputs
Memory description
User logic 250 kB application User logic 250 kB data
Operating distance
<= 300 m between station discrete input <= 300 m between station discrete output
Safety module name
XPSMF40
Discrete I/O number
24 configurable
Overload protection
Shutdown of outputs concerned with cyclic reconnection
Safety use category
Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508
Discrete input current
100 mA
Discrete input voltage
20 V
Nominal output current
60 mA line control outputs
Discrete output current
1 A 140 °F (60 °C) channels 4, 8, 12, 16, 20 and 24) 2 A 122 °F (50 °C) channels 4, 8, 12, 16, 20 and 24) 0.5 A 140 °F (60 °C) channels 1 to 3, 5 to 7, 9 to 11,13 to 15, 17 to 19, 21 to 23) <= 7 A all channels)
Discrete output voltage
24 V DC
Maximum leakage current
1 mA 2 V at state 0 discrete output
Maximum input resistance
7 kOhm
Output voltage tolerance
+/- 2%
Number of terminal blocks
1 power supply 2 line control outputs 6 discrete input/output circuit 8 line control outputs
Product or Component Type
Preventa safety PLC compact
Safety module application
F use with numerous machine safety functions and for the protection of personel
[Us] Rated Supply Voltage
24 V DC - 15...20 %
Current state 0 guaranteed
<= 1.5 mA discrete input)
Current state 1 guaranteed
3.5...4.5 mA discrete input)
Voltage state 0 guaranteed
<= 24 V discrete input
Voltage state 1 guaranteed
24...30 V discrete input
Communication port protocol
Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better Profibus 1 SUB-D 9-pin female, RS485 shielded dual twisted pair cable
Input overvoltage protection
-10…35 V discrete input
Maximum discrete input number
24 not isolated
Maximum discrete output number
24 not isolated

Compatibility Information

Match XPSMF4040 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing XPSMF4040.

Maintenance Tips

Store XPSMF4040 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options