Schneider Electric XPSMF3542
Product information
SKU: XPSMF3542
Alternate: XPSMF3542
Brand
Schneider Electric
Part No.
XPSMF3542
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
Schneider Electric XPSMF3542
Product overview
The Schneider Electric XPSMF3542 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Analogue Output Type: Not isolated
- Analogue input number: 8
- Analogue input range: 0...20 mA 500 Ohm 0...10 V
- Analogue input resolution: 12 bits
- Characteristic: Value(s)
- Clock: With, supplied by backup capacitor for 1 week following loss of supply
- Counting input number: 2
- Current state 0 guaranteed: 1...1.5 mA discrete input)
- Current state 1 guaranteed: 3.5...4.5 mA discrete input)
- Discrete input current: 100 mA
- Discrete input number: 24 not isolated
- Discrete input voltage: 20 V
- Discrete output current: 1 A 140 °F (60 °C) channels 4 and 8) 2 A 122 °F (50 °C) channels 4 and 8) 0.5 A 140 °F (60 °C) channels 1 to 3 and 5 to 7) <= 7 mA all channels)
- Discrete output number: 8
- Discrete output voltage: 24 V DC
- External resistance: 250 Ohm analogue input circuit 500 Ohm analogue input circuit
- Function of module: Closed circuit scanning of input channels analogue input circuit Measuring 0 to 20 mA currents using shunt analogue input circuit Monitoring safety actuators discrete output Monitoring safety detection discrete input Monitoring safety dialogue discrete input Monitoring safety dialogue discrete output Single-pole measuring of 0 to 10 V voltages analogue input circuit
- Input current limits: 0.4â¦23 mA 500 Ohm analogue input circuit
- Input overvoltage protection: 500 V discrete input IEC 61000-4-5 -4â¦15 V analogue input circuit
- Input protection type: Protected against short-circuit to earth Protected against short-circuit
- Input voltage limits: 0.1...11.5 V analogue input circuit
- Maximum internal input resistance: 500 MOhm for signal source analogue input circuit 1 kOhm analogue input circuit 3.7 Ohm counting inputs
- Maximum leakage current: 1 mA 2 V at state 0 discrete output
- Memory description: User logic 250 kB application User logic 250 kB data
- Minimum load: 2 mA per discrete output
- No load current: 0.75 A
- Output voltage tolerance: +/- 2%
- Overload protection: Shutdown of outputs concerned with cyclic reconnection
- Product or Component Type: Preventa safety PLC compact
- Protection Type: Internal fuse
- Range of Product: Preventa Safety automation
- Response Time: Depending on size of application
- Safety accuracy: +/- 2 % analogue input circuit
- Safety module application: For numerous machine safety functions and for the protection of personnel
- Safety module name: XPSMF35
- Safety use category: Category 4 EN 954-1/ISO 13849-1 SIL 3 IEC 61508
- Structure type: 10BASE-T/100BASE-TX, Modbus TCP/IP 10BASE-T/100BASE-TX, safe Ethernet
- Voltage state 0 guaranteed: <= 5 V discrete input
- Voltage state 1 guaranteed: 24...30 V discrete input
- [Us] Rated Supply Voltage: 24 V DC - 15...20 %
Condition and supply
- Price on request: send an inquiry with the quantity you need
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number XPSMF3542 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- XPSMF3542
- Brand
- Schneider Electric
- Part Number
- XPSMF3542
- Category
- Schneider Electric Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Clock
- With, supplied by backup capacitor for 1 week following loss of supply
- Minimum load
- 2 mA per discrete output
- Response Time
- Depending on size of application
- Characteristic
- Value(s)
- Structure type
- 10BASE-T/100BASE-TX, Modbus TCP/IP 10BASE-T/100BASE-TX, safe Ethernet
- No load current
- 0.75 A
- Protection Type
- Internal fuse
- Safety accuracy
- +/- 2 % analogue input circuit
- Range of Product
- Preventa Safety automation
- Function of module
- Closed circuit scanning of input channels analogue input circuit Measuring 0 to 20 mA currents using shunt analogue input circuit Monitoring safety actuators discrete output Monitoring safety detection discrete input Monitoring safety dialogue discrete input Monitoring safety dialogue discrete output Single-pole measuring of 0 to 10 V voltages analogue input circuit
- Memory description
- User logic 250 kB application User logic 250 kB data
- Safety module name
- XPSMF35
- External resistance
- 250 Ohm analogue input circuit 500 Ohm analogue input circuit
- Overload protection
- Shutdown of outputs concerned with cyclic reconnection
- Safety use category
- Category 4 EN 954-1/ISO 13849-1 SIL 3 IEC 61508
- Analogue Output Type
- Not isolated
- Analogue input range
- 0...20 mA 500 Ohm 0...10 V
- Input current limits
- 0.4â¦23 mA 500 Ohm analogue input circuit
- Input voltage limits
- 0.1...11.5 V analogue input circuit
- Analogue input number
- 8
- Counting input number
- 2
- Discrete input number
- 24 not isolated
- Input protection type
- Protected against short-circuit to earth Protected against short-circuit
- Discrete input current
- 100 mA
- Discrete input voltage
- 20 V
- Discrete output number
- 8
- Discrete output current
- 1 A 140 °F (60 °C) channels 4 and 8) 2 A 122 °F (50 °C) channels 4 and 8) 0.5 A 140 °F (60 °C) channels 1 to 3 and 5 to 7) <= 7 mA all channels)
- Discrete output voltage
- 24 V DC
- Maximum leakage current
- 1 mA 2 V at state 0 discrete output
- Output voltage tolerance
- +/- 2%
- Analogue input resolution
- 12 bits
- Product or Component Type
- Preventa safety PLC compact
- Safety module application
- For numerous machine safety functions and for the protection of personnel
- [Us] Rated Supply Voltage
- 24 V DC - 15...20 %
- Current state 0 guaranteed
- 1...1.5 mA discrete input)
- Current state 1 guaranteed
- 3.5...4.5 mA discrete input)
- Voltage state 0 guaranteed
- <= 5 V discrete input
- Voltage state 1 guaranteed
- 24...30 V discrete input
- Input overvoltage protection
- 500 V discrete input IEC 61000-4-5 -4â¦15 V analogue input circuit
- Maximum internal input resistance
- 500 MOhm for signal source analogue input circuit 1 kOhm analogue input circuit 3.7 Ohm counting inputs
Compatibility Information
Match XPSMF3542 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the Schneider Electric documentation for the host system when replacing XPSMF3542.
Maintenance Tips
Store XPSMF3542 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. XPSMF3542 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
XPSMF3542 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match XPSMF3542 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
Schneider Electric ZR2FA2
SKU: ZR2FA2
Schneider Electric ZMLPA2P0SH
SKU: ZMLPA2P0SH
Schneider Electric ZMLPA2N0SH
SKU: ZMLPA2N0SH
Schneider Electric ZMLPA1P2SW
SKU: ZMLPA1P2SW