Product Description

Schneider Electric XPSAK371144 Product overview The Schneider Electric XPSAK371144 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 - Breaking capacity: 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output - Characteristic: Value(s) - Connections - terminals: Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel - Current consumption: 30 mA 24 V AC on power supply - Function of module: Multiple emergency stop monitoring 2-channel wiring Proximity sensor monitoring Monitoring of a movable guard Sensing mat and edges monitoring Emergency stop with 2 NC contacts monitoring 2-channel wiring Emergency stop monitoring 1-channel wiring Monitoring of a movable guard associated with 2 switches and automatic start Monitoring of electro-sensitive protection equipment (ESPE) - Input protection type: Internal, electronic - Local signalling: 4 LEDs - Maximum line resistance: 28 Ohm - Maximum power consumption in VA: 6 VA AC - Maximum response time on input open: 40 ms - Minimum output current: 10 mA relay output - Minimum output voltage: 17 V relay output - Mounting Support: 35 mm symmetrical DIN rail - Number of additional circuits: 1 NC + 4 solid state outputs - Output thermal current: 6 A per relay relay output - Output type: Relay instantaneous opening, 3 NO, volt-free - Product Weight: 0.9 lb(US) (0.4 kg) - Product or Component Type: Preventa safety module - Range of Product: Preventa Safety automation - Safety level: Can reach PL e/category 4 EN/ISO 13849-1 Can reach SILCL 3 EN/IEC 62061 - Safety module application: For emergency stop, switch, sensing mat/edges or safety light curtain monitoring - Safety module name: XPSAK - Safety reliability data: DC > 99 % EN/ISO 13849-1 MTTFd = 154.5 years EN/ISO 13849-1 PFHd = 7.39E-9 1/h EN/IEC 62061 - Supply frequency: 50/60 Hz - Synchronisation time between inputs: Unlimited (manual start) 2 or 4 s depending of wiring (automatic start) - Type of start: Configurable - [Ith] conventional free air thermal current: 18 A - [Uc] control circuit voltage: 24 V DC - [Ui] rated insulation voltage: 300 V 2)IEC 60947-5-1 300 V 2)DIN VDE 0110 part 1 - [Uimp] rated impulse withstand voltage: 4 kV III IEC 60947-5-1 4 kV III DIN VDE 0110 part 1 - [Us] Rated Supply Voltage: 230 V AC - 15...10 % 24 V DC - 15...10 % Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number XPSAK371144 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
XPSAK371144
Brand
Schneider Electric
Part Number
XPSAK371144
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Packaging
New surplus, factory sealed original packaging
Output type
Relay instantaneous opening, 3 NO, volt-free
Safety level
Can reach PL e/category 4 EN/ISO 13849-1 Can reach SILCL 3 EN/IEC 62061
Type of start
Configurable
Characteristic
Value(s)
Product Weight
0.9 lb(US) (0.4 kg)
Local signalling
4 LEDs
Mounting Support
35 mm symmetrical DIN rail
Range of Product
Preventa Safety automation
Supply frequency
50/60 Hz
Breaking capacity
180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output
Function of module
Multiple emergency stop monitoring 2-channel wiring Proximity sensor monitoring Monitoring of a movable guard Sensing mat and edges monitoring Emergency stop with 2 NC contacts monitoring 2-channel wiring Emergency stop monitoring 1-channel wiring Monitoring of a movable guard associated with 2 switches and automatic start Monitoring of electro-sensitive protection equipment (ESPE)
Safety module name
XPSAK
Current consumption
30 mA 24 V AC on power supply
Input protection type
Internal, electronic
Associated fuse rating
4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current
10 mA relay output
Minimum output voltage
17 V relay output
Output thermal current
6 A per relay relay output
Connections - terminals
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Maximum line resistance
28 Ohm
Safety reliability data
DC > 99 % EN/ISO 13849-1 MTTFd = 154.5 years EN/ISO 13849-1 PFHd = 7.39E-9 1/h EN/IEC 62061
Product or Component Type
Preventa safety module
Safety module application
For emergency stop, switch, sensing mat/edges or safety light curtain monitoring
[Us] Rated Supply Voltage
230 V AC - 15...10 % 24 V DC - 15...10 %
[Uc] control circuit voltage
24 V DC
Number of additional circuits
1 NC + 4 solid state outputs
[Ui] rated insulation voltage
300 V 2)IEC 60947-5-1 300 V 2)DIN VDE 0110 part 1
Maximum power consumption in VA
6 VA AC
Maximum response time on input open
40 ms
Synchronisation time between inputs
Unlimited (manual start) 2 or 4 s depending of wiring (automatic start)
[Uimp] rated impulse withstand voltage
4 kV III IEC 60947-5-1 4 kV III DIN VDE 0110 part 1
[Ith] conventional free air thermal current
18 A

Compatibility Information

Match XPSAK371144 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing XPSAK371144.

Maintenance Tips

Store XPSAK371144 dry and dust-free in its packaging until installation.