+86 13348028050
XPSAK361144 Schneider Electric XPSAK361144 - Front View | Vcocnc FANUC Parts

Schneider Electric XPSAK361144

Product information

$813.62 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: XPSAK361144

Alternate: XPSAK361144

Brand
Schneider Electric
Part No.
XPSAK361144
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric XPSAK361144 Product overview The Schneider Electric XPSAK361144 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 4 A gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 - Breaking capacity: 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output - Characteristic: Value(s) - Connections - terminals: Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel - Current consumption: 30 mA at 24 V AC on power supply - Function of module: Monitoring of electro-sensitive protection equipment (ESPE) Monitoring of a movable guard associated with 2 switches and automatic start Monitoring of a movable guard Multiple emergency stop monitoring 2-channel wiring Emergency stop with 2 NC contacts monitoring 2-channel wiring Sensing mat and edges monitoring Proximity sensor monitoring Emergency stop monitoring 1-channel wiring - Input protection type: Internal, electronic - Local signalling: 4 LEDs - Maximum line resistance: 28 Ohm - Maximum power consumption in VA: 6 VA AC - Maximum response time on input open: 40 ms - Minimum output current: 10 mA for relay output - Minimum output voltage: 17 V for relay output - Mounting support: 35 mm symmetrical DIN rail - Number of additional circuits: 1 NC + 4 solid state outputs - Output thermal current: 6 A per relay for relay output - Output type: Relay instantaneous opening, 3 NO circuit(s), volt-free - Product or component type: Preventa safety module - Product weight: 0.4 kg - Range of product: Preventa Safety automation - Safety level: Can reach PL e/category 4 conforming to EN/ISO 13849-1 Can reach SILCL 3 conforming to EN/IEC 62061 - Safety module application: For emergency stop, switch, sensing mat/edges or safety light curtain monitoring - Safety module name: XPSAK - Safety reliability data: DC > 99 % conforming to EN/ISO 13849-1 MTTFd = 154.5 years conforming to EN/ISO 13849-1 PFHd = 7.39E-9 1/h conforming to EN/IEC 62061 - Supply frequency: 50/60 Hz - Synchronisation time between inputs: Unlimited (manual start) 2 or 4 s depending of wiring (automatic start) - Type of start: Configurable - [Ith] conventional free air thermal current: 18 A - [Uc] control circuit voltage: 24 V DC - [Ui] rated insulation voltage: 300 V (pollution degree 2) conforming to IEC 60947-5-1 300 V (pollution degree 2) conforming to DIN VDE 0110 part 1 - [Uimp] rated impulse withstand voltage: 4 kV overvoltage category III conforming to IEC 60947-5-1 4 kV overvoltage category III conforming to DIN VDE 0110 part 1 - [Us] rated supply voltage: 110 V AC - 15...10 % 24 V DC - 15...10 % Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number XPSAK361144 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
XPSAK361144
Brand
Schneider Electric
Part Number
XPSAK361144
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Packaging
New surplus, never used
Output type
Relay instantaneous opening, 3 NO circuit(s), volt-free
Safety level
Can reach PL e/category 4 conforming to EN/ISO 13849-1 Can reach SILCL 3 conforming to EN/IEC 62061
Type of start
Configurable
Characteristic
Value(s)
Product weight
0.4 kg
Local signalling
4 LEDs
Mounting support
35 mm symmetrical DIN rail
Range of product
Preventa Safety automation
Supply frequency
50/60 Hz
Breaking capacity
180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output
Function of module
Monitoring of electro-sensitive protection equipment (ESPE) Monitoring of a movable guard associated with 2 switches and automatic start Monitoring of a movable guard Multiple emergency stop monitoring 2-channel wiring Emergency stop with 2 NC contacts monitoring 2-channel wiring Sensing mat and edges monitoring Proximity sensor monitoring Emergency stop monitoring 1-channel wiring
Safety module name
XPSAK
Current consumption
30 mA at 24 V AC on power supply
Input protection type
Internal, electronic
Associated fuse rating
4 A gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current
10 mA for relay output
Minimum output voltage
17 V for relay output
Output thermal current
6 A per relay for relay output
Connections - terminals
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Maximum line resistance
28 Ohm
Safety reliability data
DC > 99 % conforming to EN/ISO 13849-1 MTTFd = 154.5 years conforming to EN/ISO 13849-1 PFHd = 7.39E-9 1/h conforming to EN/IEC 62061
Product or component type
Preventa safety module
Safety module application
For emergency stop, switch, sensing mat/edges or safety light curtain monitoring
[Us] rated supply voltage
110 V AC - 15...10 % 24 V DC - 15...10 %
[Uc] control circuit voltage
24 V DC
Number of additional circuits
1 NC + 4 solid state outputs
[Ui] rated insulation voltage
300 V (pollution degree 2) conforming to IEC 60947-5-1 300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
Maximum power consumption in VA
6 VA AC
Maximum response time on input open
40 ms
Synchronisation time between inputs
Unlimited (manual start) 2 or 4 s depending of wiring (automatic start)
[Uimp] rated impulse withstand voltage
4 kV overvoltage category III conforming to IEC 60947-5-1 4 kV overvoltage category III conforming to DIN VDE 0110 part 1
[Ith] conventional free air thermal current
18 A

Compatibility Information

Match XPSAK361144 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing XPSAK361144.

Maintenance Tips

Store XPSAK361144 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options