Schneider Electric XPSAC1321 Product overview The Schneider Electric XPSAC1321 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 - Breaking capacity: 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output - Characteristic: Value(s) - Connections - terminals: Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible without cable end Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid without cable end Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible without cable end Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid without cable end Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel - Current consumption: 100 mA 48 V AC on power supply - Function of module: Emergency stop Switch monitoring - Local signalling: 2 LEDs - Maximum power consumption in VA: 6 VA AC - Maximum response time on input open: 100 ms - Minimum output current: 10 mA relay output - Minimum output voltage: 16 V relay output - Mounting Support: 35 mm symmetrical DIN rail - Number of additional circuits: 1 solid state output - Output thermal current: 6 A per relay relay output - Output type: Relay instantaneous opening, 3 NO, volt-free - Product Weight: 0.46 lb(US) (0.21 kg) - Product or Component Type: Preventa safety module - Range of Product: Preventa Safety automation - Safety level: Can reach PL e/category 4 EN/ISO 13849-1 Can reach SILCL 3 EN/IEC 62061 - Safety module application: For emergency stop and switch monitoring - Safety module name: XPSAC - Safety reliability data: MTTFd = 210.4 years EN/ISO 13849-1 DC > 99 % EN/ISO 13849-1 PFHd = 3.56E-9 1/h EN/IEC 62061 - Supply frequency: 50/60 Hz - Type of start: Unmonitored - [Ith] conventional free air thermal current: 10.5 A - [Uc] control circuit voltage: 48 V - [Ui] rated insulation voltage: 300 V 2)IEC 60947-5-1 300 V 2)DIN VDE 0110 part 1 - [Uimp] rated impulse withstand voltage: 4 kV III IEC 60947-5-1 4 kV III DIN VDE 0110 part 1 - [Us] Rated Supply Voltage: 48 V AC - 15...10 % Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number XPSAC1321 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
XPSAC1321
Brand
Schneider Electric
Part Number
XPSAC1321
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Output type
Relay instantaneous opening, 3 NO, volt-free
Safety level
Can reach PL e/category 4 EN/ISO 13849-1 Can reach SILCL 3 EN/IEC 62061
Type of start
Unmonitored
Characteristic
Value(s)
Product Weight
0.46 lb(US) (0.21 kg)
Local signalling
2 LEDs
Mounting Support
35 mm symmetrical DIN rail
Range of Product
Preventa Safety automation
Supply frequency
50/60 Hz
Breaking capacity
180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output
Function of module
Emergency stop Switch monitoring
Safety module name
XPSAC
Current consumption
100 mA 48 V AC on power supply
Associated fuse rating
4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current
10 mA relay output
Minimum output voltage
16 V relay output
Output thermal current
6 A per relay relay output
Connections - terminals
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible without cable end Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid without cable end Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible without cable end Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid without cable end Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Safety reliability data
MTTFd = 210.4 years EN/ISO 13849-1 DC > 99 % EN/ISO 13849-1 PFHd = 3.56E-9 1/h EN/IEC 62061
Product or Component Type
Preventa safety module
Safety module application
For emergency stop and switch monitoring
[Us] Rated Supply Voltage
48 V AC - 15...10 %
[Uc] control circuit voltage
48 V
Number of additional circuits
1 solid state output
[Ui] rated insulation voltage
300 V 2)IEC 60947-5-1 300 V 2)DIN VDE 0110 part 1
Maximum power consumption in VA
6 VA AC
Maximum response time on input open
100 ms
[Uimp] rated impulse withstand voltage
4 kV III IEC 60947-5-1 4 kV III DIN VDE 0110 part 1
[Ith] conventional free air thermal current
10.5 A

Compatibility Information

Match XPSAC1321 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing XPSAC1321.

Maintenance Tips

Store XPSAC1321 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options