+86 13348028050
XPS-BF1132 Schneider Electric XPS-BF1132 - Front View | Vcocnc FANUC Parts

Schneider Electric XPS-BF1132

Product information

$1,075.97 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: XPS-BF1132

Alternate: XPSBF1132

Brand
Schneider Electric
Part No.
XPS-BF1132
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric XPS-BF1132 Product overview The Schneider Electric XPS-BF1132 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 - Breaking capacity: 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output - Characteristic: Value(s) - Connections - terminals: Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible without cable end Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid without cable end Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible without cable end Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid without cable end Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel - Current consumption: 8 mA 24 V DC on power supply - Function of module: Monitoring two-hand control station and a foot switch - Input compatibility: Two-hand control EN 574/ISO 13851-III C - Input protection type: Internal, electronic - Local signalling: 3 LEDs - Maximum response time on input open: 20 ms - Minimum output current: 10 mA relay output - Minimum output voltage: 17 V relay output - Mounting Support: 35 mm symmetrical DIN rail - Number of Inputs: 1 NC + NO - Number of additional circuits: 2 solid state outputs - Output thermal current: 4.2 A per relay relay output - Output type: Relay, 2 NO, volt-free - Power Consumption in W: 2.5 W - Product Weight: 0.33 lb(US) (0.15 kg) - Product or Component Type: Preventa safety module - Range of Product: Preventa Safety automation - Safety level: Can reach PL e/category 4 EN/ISO 13849-1 Can reach SILCL 3 EN/IEC 62061 - Safety module application: For electrical monitoring of two-hand control stations - Safety module name: XPSBF - Safety reliability data: DC > 99 % EN/ISO 13849-1 MTTFd = 50.1 years EN/ISO 13849-1 PFHd = 1.3E-8 1/h EN/IEC 62061 - Synchronisation time between inputs: 0.5 s - [Ith] conventional free air thermal current: 8.4 A - [Uc] control circuit voltage: 24 V DC - [Ui] rated insulation voltage: 300 V 2)IEC 60947-5-1 300 V 2)DIN VDE 0110 part 1 - [Uimp] rated impulse withstand voltage: 4 kV III IEC 60947-5-1 4 kV III DIN VDE 0110 part 1 - [Us] Rated Supply Voltage: 24 V DC - 20...20 % Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number XPS-BF1132 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
XPS-BF1132
Brand
Schneider Electric
Part Number
XPS-BF1132
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Packaging
New surplus, never used
Output type
Relay, 2 NO, volt-free
Safety level
Can reach PL e/category 4 EN/ISO 13849-1 Can reach SILCL 3 EN/IEC 62061
Characteristic
Value(s)
Product Weight
0.33 lb(US) (0.15 kg)
Local signalling
3 LEDs
Mounting Support
35 mm symmetrical DIN rail
Number of Inputs
1 NC + NO
Range of Product
Preventa Safety automation
Breaking capacity
180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output
Function of module
Monitoring two-hand control station and a foot switch
Safety module name
XPSBF
Current consumption
8 mA 24 V DC on power supply
Input compatibility
Two-hand control EN 574/ISO 13851-III C
Input protection type
Internal, electronic
Associated fuse rating
4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current
10 mA relay output
Minimum output voltage
17 V relay output
Output thermal current
4.2 A per relay relay output
Power Consumption in W
2.5 W
Connections - terminals
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible without cable end Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid without cable end Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible without cable end Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid without cable end Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Safety reliability data
DC > 99 % EN/ISO 13849-1 MTTFd = 50.1 years EN/ISO 13849-1 PFHd = 1.3E-8 1/h EN/IEC 62061
Product or Component Type
Preventa safety module
Safety module application
For electrical monitoring of two-hand control stations
[Us] Rated Supply Voltage
24 V DC - 20...20 %
[Uc] control circuit voltage
24 V DC
Number of additional circuits
2 solid state outputs
[Ui] rated insulation voltage
300 V 2)IEC 60947-5-1 300 V 2)DIN VDE 0110 part 1
Maximum response time on input open
20 ms
Synchronisation time between inputs
0.5 s
[Uimp] rated impulse withstand voltage
4 kV III IEC 60947-5-1 4 kV III DIN VDE 0110 part 1
[Ith] conventional free air thermal current
8.4 A

Compatibility Information

Match XPS-BF1132 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing XPS-BF1132.

Maintenance Tips

Store XPS-BF1132 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options