+86 13348028050
TM3SAK6RG Schneider Electric TM3SAK6RG - Front View | Vcocnc FANUC Parts

Schneider Electric TM3SAK6RG

Product information

SKU: TM3SAK6RG

Alternate: TM3SAK6RG

Brand
Schneider Electric
Part No.
TM3SAK6RG
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric TM3SAK6RG Product overview The Schneider Electric TM3SAK6RG is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 4 A gG or gL relay output IEC 60947-5-1 6 A fast blow relay output IEC 60947-5-1 - Breaking capacity: 360 VA holding AC-15 B300 relay output 3600 VA inrush AC-15 B300 relay output - Characteristic: Value(s) - Connections - terminals: Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals Captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals Captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals - Current consumption: 100 mA 24 V DC external supply - Device short name: TM3SAK - Electrical Connection: Spring terminal - Function of module: Emergency stop monitoring 1-channel wiring Emergency stop monitoring 2-channel wiring Monitoring of a movable guard with 2 switches and automatic start Monitoring of a movable guard Multiple emergency stop monitoring 2-channel wiring Proximity sensor monitoring PNP/PNP Proximity sensor monitoring PNP/NPN Sensing mat and edges monitoring Monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP Monitoring of electro-sensitive protection equipment (ESPE) PNP/NPN - Input protection type: Internal, electronic - Local signalling: 8 LEDs (green/red) for user - Maximum cable distance between devices: 98.4 ft (30 m) - Maximum response time on input open: 40 ms - Maximum switching voltage: 230 V AC-15 50 Hz relay instantaneous opening) 24 V DC-13 relay instantaneous opening) - Minimum output current: 10 mA relay output - Number of safety circuits: 3 NO relay instantaneous opening - Output thermal current: 6 A per relay relay output - Output type: Relay instantaneous opening, 3 NO, potential free - Output voltage: 10 V relay output - Power consumption in W: 0.2 W 5 V DC 3.6 W 24 V DC - Product compatibility: Safety light curtains EN/IEC 61496-1 (type 4) Sensing mat/edges EN 1760-1 - Product or Component Type: Safety module - Range of Product: Modicon TM3 Safety - Safety level: Can reach PL e/category 4 ISO 13849-1 2008 Can reach PL e/category 4 ISO 13849-2 2012 Can reach SILCL 3 IEC 62061 2005 Can reach SIL 3 IEC 61508 2010 - Safety module application: For emergency stop, switch, sensing mat/edges or safety light curtain monitoring - Safety reliability data: DC = 95 % ISO 13849-1 PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A MTTFd = 500 years ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A MTTFd = 85 years ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A SFF = 95 % IEC 61508-1 HFT = 1 IEC 61508-1 Type = A IEC 61508-1 - Standards: ISO 13849-1:2008 ISO 13849-2:2012 IEC 62061:2005 IEC 61508:2010 IEC 60947-5-1:2010 IEC 61131-2:2007 IEC 60204-1:2005 IEC 60204-1:2009/A1 IEC 61010-1:2010 EN 50581:2012 - Synchronisation time between inputs: Unlimited 2 or 4 s depending of wiring configurable by software - [Ith] conventional free air thermal current: 18 A - [Uc] control circuit voltage: 24 V DC - [Ui] rated insulation voltage: 300 V 2)IEC 60647-5-1 - [Uimp] rated impulse withstand voltage: 4 kV III IEC 60647-5-1 - [Us] rated supply voltage: 24 V - 15...20 % DC Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number TM3SAK6RG with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
TM3SAK6RG
Brand
Schneider Electric
Part Number
TM3SAK6RG
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Standards
ISO 13849-1:2008 ISO 13849-2:2012 IEC 62061:2005 IEC 61508:2010 IEC 60947-5-1:2010 IEC 61131-2:2007 IEC 60204-1:2005 IEC 60204-1:2009/A1 IEC 61010-1:2010 EN 50581:2012
Output type
Relay instantaneous opening, 3 NO, potential free
Safety level
Can reach PL e/category 4 ISO 13849-1 2008 Can reach PL e/category 4 ISO 13849-2 2012 Can reach SILCL 3 IEC 62061 2005 Can reach SIL 3 IEC 61508 2010
Characteristic
Value(s)
Output voltage
10 V relay output
Local signalling
8 LEDs (green/red) for user
Range of Product
Modicon TM3 Safety
Breaking capacity
360 VA holding AC-15 B300 relay output 3600 VA inrush AC-15 B300 relay output
Device short name
TM3SAK
Function of module
Emergency stop monitoring 1-channel wiring Emergency stop monitoring 2-channel wiring Monitoring of a movable guard with 2 switches and automatic start Monitoring of a movable guard Multiple emergency stop monitoring 2-channel wiring Proximity sensor monitoring PNP/PNP Proximity sensor monitoring PNP/NPN Sensing mat and edges monitoring Monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP Monitoring of electro-sensitive protection equipment (ESPE) PNP/NPN
Current consumption
100 mA 24 V DC external supply
Electrical Connection
Spring terminal
Input protection type
Internal, electronic
Product compatibility
Safety light curtains EN/IEC 61496-1 (type 4) Sensing mat/edges EN 1760-1
Associated fuse rating
4 A gG or gL relay output IEC 60947-5-1 6 A fast blow relay output IEC 60947-5-1
Minimum output current
10 mA relay output
Output thermal current
6 A per relay relay output
Power consumption in W
0.2 W 5 V DC 3.6 W 24 V DC
Connections - terminals
Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals Captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals Captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
Safety reliability data
DC = 95 % ISO 13849-1 PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A MTTFd = 500 years ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A MTTFd = 85 years ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A SFF = 95 % IEC 61508-1 HFT = 1 IEC 61508-1 Type = A IEC 61508-1
Maximum switching voltage
230 V AC-15 50 Hz relay instantaneous opening) 24 V DC-13 relay instantaneous opening)
Number of safety circuits
3 NO relay instantaneous opening
Product or Component Type
Safety module
Safety module application
For emergency stop, switch, sensing mat/edges or safety light curtain monitoring
[Us] rated supply voltage
24 V - 15...20 % DC
[Uc] control circuit voltage
24 V DC
[Ui] rated insulation voltage
300 V 2)IEC 60647-5-1
Maximum response time on input open
40 ms
Synchronisation time between inputs
Unlimited 2 or 4 s depending of wiring configurable by software
Maximum cable distance between devices
98.4 ft (30 m)
[Uimp] rated impulse withstand voltage
4 kV III IEC 60647-5-1
[Ith] conventional free air thermal current
18 A

Compatibility Information

Match TM3SAK6RG against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing TM3SAK6RG.

Maintenance Tips

Store TM3SAK6RG dry and dust-free in its packaging until installation.