+86 13348028050
TM100C40RN Schneider Electric TM100C40RN - Front View | Vcocnc FANUC Parts

Schneider Electric TM100C40RN

Product information

$207.50 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: TM100C40RN

Alternate: TM100C40RN

Brand
Schneider Electric
Part No.
TM100C40RN
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric TM100C40RN Product overview The Schneider Electric TM100C40RN is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Clock drift: <= 90 s/month at 25 °C - Communication port protocol: USB port: USB - SoMachine-Network Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network - Configurable filtering time: 0 ms for input 3 ms for input 12 ms for input - Control signal type: Quadrature (x1, x2, x4) at 60 kHz for fast input (HSC mode) Pulse/direction at 60 kHz for fast input (HSC mode) Single phase at 60 kHz for fast input (HSC mode) CW/CCW at 60 kHz for fast input (HSC mode) - Counting input number: 2 fast input (HSC mode) at 60 kHz 32 bits - Data storage equipment: 32 GB micro SD card (optional) - Discrete I/O number: 40 - Discrete input current: 7 mA for regular input 7 mA for fast input 9 mA for high speed input - Discrete input number: I2...I5: 4 fast input I0...I1: 2 high speed input I6...I23: 18 regular input - Discrete input voltage: 24 V - Discrete input voltage type: DC - Discrete output current: 2 A - Discrete output number: 16 relay - Discrete output type: Relay normally open - Discrete output voltage: 24 V DC 220 V AC - Electrical durability: 100000 cycles AC-12, 240 V, 480 VA, resistive 100000 cycles DC-12, 24 V, 48 W, resistive - Exct time for event task: 60 µs response time - Execution time for 1 KInstruction: 0.3 ms for event and periodic task - Execution time per instruction: 0.2 µs Boolean - Input impedance: 3.3 kOhm for regular input 3.3 kOhm for fast input 2.81 kOhm for high speed input - Inrush current: 50 A - Integrated connection type: USB port with mini B USB 2.0 connector Non isolated serial link serial 1 with terminal block connector and RS485 interface Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface - Maximum current per output common: 4 A at COM 0 4 A at COM 1 4 A at COM 2 4 A at COM 3 - Mechanical durability: 20000000 cycles for relay output - Memory capacity: 1024 kB internal flash with 10000 instructions for backup of programs - Minimum load: 10 mA at 5 V DC for relay output - Network frequency: 50/60 Hz - Output voltage limits: 30 V DC 250 V AC - Power consumption in VA: 35…45 VA at 100...240 V AC (with max I/O) - Product or component type: Logic controller - Range of product: Easy Modicon M100 - Regulation loop: Adjustable PID regulator up to 14 simultaneous loops - Response time: 35 µs turn-on, I2...I5 terminal(s) for fast input 100 µs turn-off, I2...I5 terminal(s) for fast input 5 µs turn-on, I0...I1 terminal(s) for high speed input 5 µs turn-off, I0...I1 terminal(s) for high speed input 35 µs turn-on, I6...I13 terminal(s) for regular input 100 µs turn-off, I6...I13 terminal(s) for regular input 10 ms turn-on, Q0...Q15 terminal(s) for relay output 10 ms turn-off, Q0...Q15 terminal(s) for relay output 55 µs turn-on, I14...I23 terminal(s) for regular input 125 µs turn-off, I14...I23 terminal(s) for regular input - Supply voltage limits: 85…264 V - Switching frequency: 0.1 Hz with maximum load 5 Hz without maximum load - Transmission rate: 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 12 Mbit/s for USB - Voltage state 0 guaranteed: <= 5 V for input - Voltage state 1 guaranteed: >= 15 V for input - [Us] rated supply voltage: 100...240 V AC Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number TM100C40RN with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
TM100C40RN
Brand
Schneider Electric
Part Number
TM100C40RN
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Packaging
New surplus, factory sealed original packaging
Clock drift
<= 90 s/month at 25 °C
Minimum load
10 mA at 5 V DC for relay output
Response time
35 µs turn-on, I2...I5 terminal(s) for fast input 100 µs turn-off, I2...I5 terminal(s) for fast input 5 µs turn-on, I0...I1 terminal(s) for high speed input 5 µs turn-off, I0...I1 terminal(s) for high speed input 35 µs turn-on, I6...I13 terminal(s) for regular input 100 µs turn-off, I6...I13 terminal(s) for regular input 10 ms turn-on, Q0...Q15 terminal(s) for relay output 10 ms turn-off, Q0...Q15 terminal(s) for relay output 55 µs turn-on, I14...I23 terminal(s) for regular input 125 µs turn-off, I14...I23 terminal(s) for regular input
Characteristic
Value(s)
Inrush current
50 A
Input impedance
3.3 kOhm for regular input 3.3 kOhm for fast input 2.81 kOhm for high speed input
Memory capacity
1024 kB internal flash with 10000 instructions for backup of programs
Regulation loop
Adjustable PID regulator up to 14 simultaneous loops
Range of product
Easy Modicon M100
Network frequency
50/60 Hz
Transmission rate
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 12 Mbit/s for USB
Control signal type
Quadrature (x1, x2, x4) at 60 kHz for fast input (HSC mode) Pulse/direction at 60 kHz for fast input (HSC mode) Single phase at 60 kHz for fast input (HSC mode) CW/CCW at 60 kHz for fast input (HSC mode)
Discrete I/O number
40
Switching frequency
0.1 Hz with maximum load 5 Hz without maximum load
Discrete output type
Relay normally open
Counting input number
2 fast input (HSC mode) at 60 kHz 32 bits
Discrete input number
I2...I5: 4 fast input I0...I1: 2 high speed input I6...I23: 18 regular input
Electrical durability
100000 cycles AC-12, 240 V, 480 VA, resistive 100000 cycles DC-12, 24 V, 48 W, resistive
Mechanical durability
20000000 cycles for relay output
Output voltage limits
30 V DC 250 V AC
Supply voltage limits
85…264 V
Data storage equipment
32 GB micro SD card (optional)
Discrete input current
7 mA for regular input 7 mA for fast input 9 mA for high speed input
Discrete input voltage
24 V
Discrete output number
16 relay
Discrete output current
2 A
Discrete output voltage
24 V DC 220 V AC
Power consumption in VA
35…45 VA at 100...240 V AC (with max I/O)
Exct time for event task
60 µs response time
Product or component type
Logic controller
[Us] rated supply voltage
100...240 V AC
Integrated connection type
USB port with mini B USB 2.0 connector Non isolated serial link serial 1 with terminal block connector and RS485 interface Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface
Voltage state 0 guaranteed
<= 5 V for input
Voltage state 1 guaranteed
>= 15 V for input
Communication port protocol
USB port: USB - SoMachine-Network Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network
Configurable filtering time
0 ms for input 3 ms for input 12 ms for input
Discrete input voltage type
DC
Execution time per instruction
0.2 µs Boolean
Execution time for 1 KInstruction
0.3 ms for event and periodic task
Maximum current per output common
4 A at COM 0 4 A at COM 1 4 A at COM 2 4 A at COM 3

Compatibility Information

Match TM100C40RN against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing TM100C40RN.

Maintenance Tips

Store TM100C40RN dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options