+86 13348028050
SV3-075L2 KEYENCE SV3-075L2 - Front View | Vcocnc FANUC Parts

KEYENCE SV3-075L2

Product information

SKU: SV3-075L2

Alternate: SV3075L2

Brand
KEYENCE
Part No.
SV3-075L2
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE SV3-075L2 Product overview The KEYENCE SV3-075L2 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Allowable frequency fluctuation / Main circuit/control circuit: ±5% max. - Altitude: No more than 2,000 m 6,561.7' above sea level (reduced ratings at 1,000 m 3,280.8' or higher) - Applied standard / UL/CSA standards: UL 61800-5-1, CSA 22.2 No. 274 - CE marking / Machinery Directive: EN 61800-5-1, EN 61800-5-2, EN ISO 13849-1:2015 Cat. 3 PLe, EN IEC 62061 Maximum SIL3 - Control circuit: Single-phase 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC *2 - Control circuit power loss: 14 W - Control mode: Three-phase full-wave rectification, IGBT, PWM control, Sine wave current drive system - EMI: EN55011 Class A, EN61800-3, EN61000-6-4 - EMS: EN61800-3, EN61000-6-2 - Feedback: Serial encoder (absolute) communication, Fully closed control serial communication, Analog feedback - General specifications / Capacity: 750 W - Impact resistance: 19.6 m/s 2 64.3 ft/s 2 (Compliant with JIS C60068-2-27) - Input: STO1, STO2: Power module base block signals Internal impedance: 5.1 kΩ Operable voltage range: +24 V, ±20% Max. delay time: 4 ms (Time from when STO1 and STO2 are turned off until motor current is interrupted) - Input power supply / Voltage/frequency: Main circuit 3-phase (or single-phase *1 ) 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC *2 - Insulation withstand voltage: 1,500 VAC or more (between primary side and ground) 3,000 VAC or more (between primary and secondary) 350 VAC: between secondary circuit and ground - Main circuit power loss: Three-phase 200 V: 38.9 W Single-phase 200 V: 39.2 W DC 270 V: 30.7 W - Max.: 16.9 Arms - Max. applicable motor capacity: 750 W - Min. insulation resistance: 500 VDC 1 MΩ or more with insulation resistance meter - North America EMI standard: FCC Part 15 B, ICES-003. Class A - Operating ambient temperature: -5 to +60°C 23 to 140°F (No freezing) (reduced ratings at +55°C 131°F or higher) - Operating environment / Operating atmosphere: Enclosure rating IP20:SV3-005L2/010L2/020L2/040L2/075L2/100L2/150L2 IP10:SV3-200L2/300L2/500L2 - Operating/storage ambient temperature: 95% RH or less (No condensation) - Other: No static noise, strong electric or magnetic fields, or radiation - Output: EDM: Built-in safety circuit status monitoring (fixed output) Max. allowable voltage: 30 VDC Max. allowable current: 50 mA DC Max. voltage drop at ON: 1.5 V Max. delay time: 4 ms (Time from STO1 and STO2 change to EDM change) - Output current / Continuous: 5.5 Arms - Overvoltage category: III - Pollution degree: 2 (in an IP54 or higher control panel) However, the product must be used in the following environments: • No corrosive or flammable gases • No exposure to water, oil, or chemicals • No dust - Power supply capacity for 1 amplifier: Three-phase 200 V: 1.6 kVA Single-phase 200 V: 1.9 kVA DC 270 V: 1.6 kVA - Power supply/current capacity and power loss / Main circuit power supply: Three-phase 200 V/Single-phase 200 V/DC 270 V - Protection function: Overcurrent, overvoltage, undervoltage, overload, regenerative error, etc. - Regenerative resistor power loss: Three-phase 200 V: 15 W Single-phase 200 V: 15 W DC 270 V: ― - Response time: 4 ms(max) - Safety function: STO function (STO/EN 61800-5-2) - Safety function / Safety parameters: SIL 3 / EN 61508, Maximum SIL 3 / EN IEC 62061, PLe (Category 3) / EN ISO 13849-1:2015 - Storage ambient temperature: -20 to +85°C -4 to +185°F (No freezing) - Structure / Type: Base mount installation - Total power loss: Three-phase 200 V: 52.9 W Single-phase 200 V: 53.2 W DC 270 V: 44.7 W - Vibration resistance: 4.9 m/s 2 16.1 ft/s 2 (Compliant with JIS C60068-2-6) - Weight: Approx. 1.6 kg 3.53 lb Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number SV3-075L2 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
SV3-075L2
Brand
KEYENCE
Part Number
SV3-075L2
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
EMI
EN55011 Class A, EN61800-3, EN61000-6-4
EMS
EN61800-3, EN61000-6-2
Max.
16.9 Arms
Input
STO1, STO2: Power module base block signals Internal impedance: 5.1 kΩ Operable voltage range: +24 V, ±20% Max. delay time: 4 ms (Time from when STO1 and STO2 are turned off until motor current is interrupted)
Other
No static noise, strong electric or magnetic fields, or radiation
Output
EDM: Built-in safety circuit status monitoring (fixed output) Max. allowable voltage: 30 VDC Max. allowable current: 50 mA DC Max. voltage drop at ON: 1.5 V Max. delay time: 4 ms (Time from STO1 and STO2 change to EDM change)
Weight
Approx. 1.6 kg 3.53 lb
Altitude
No more than 2,000 m 6,561.7' above sea level (reduced ratings at 1,000 m 3,280.8' or higher)
Feedback
Serial encoder (absolute) communication, Fully closed control serial communication, Analog feedback
Control mode
Three-phase full-wave rectification, IGBT, PWM control, Sine wave current drive system
Response time
4 ms(max)
Control circuit
Single-phase 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC *2
Safety function
STO function (STO/EN 61800-5-2)
Pollution degree
2 (in an IP54 or higher control panel) However, the product must be used in the following environments: • No corrosive or flammable gases • No exposure to water, oil, or chemicals • No dust
Structure / Type
Base mount installation
Total power loss
Three-phase 200 V: 52.9 W Single-phase 200 V: 53.2 W DC 270 V: 44.7 W
Impact resistance
19.6 m/s 2 64.3 ft/s 2 (Compliant with JIS C60068-2-27)
Protection function
Overcurrent, overvoltage, undervoltage, overload, regenerative error, etc.
Overvoltage category
III
Vibration resistance
4.9 m/s 2 16.1 ft/s 2 (Compliant with JIS C60068-2-6)
Main circuit power loss
Three-phase 200 V: 38.9 W Single-phase 200 V: 39.2 W DC 270 V: 30.7 W
Control circuit power loss
14 W
Min. insulation resistance
500 VDC 1 MΩ or more with insulation resistance meter
North America EMI standard
FCC Part 15 B, ICES-003. Class A
Output current / Continuous
5.5 Arms
Storage ambient temperature
-20 to +85°C -4 to +185°F (No freezing)
Insulation withstand voltage
1,500 VAC or more (between primary side and ground) 3,000 VAC or more (between primary and secondary) 350 VAC: between secondary circuit and ground
Operating ambient temperature
-5 to +60°C 23 to 140°F (No freezing) (reduced ratings at +55°C 131°F or higher)
Max. applicable motor capacity
750 W
CE marking / Machinery Directive
EN 61800-5-1, EN 61800-5-2, EN ISO 13849-1:2015 Cat. 3 PLe, EN IEC 62061 Maximum SIL3
Regenerative resistor power loss
Three-phase 200 V: 15 W Single-phase 200 V: 15 W DC 270 V: ―
General specifications / Capacity
750 W
Applied standard / UL/CSA standards
UL 61800-5-1, CSA 22.2 No. 274
Safety function / Safety parameters
SIL 3 / EN 61508, Maximum SIL 3 / EN IEC 62061, PLe (Category 3) / EN ISO 13849-1:2015
Operating/storage ambient temperature
95% RH or less (No condensation)
Power supply capacity for 1 amplifier
Three-phase 200 V: 1.6 kVA Single-phase 200 V: 1.9 kVA DC 270 V: 1.6 kVA
Input power supply / Voltage/frequency
Main circuit 3-phase (or single-phase *1 ) 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC *2
Operating environment / Operating atmosphere
Enclosure rating IP20:SV3-005L2/010L2/020L2/040L2/075L2/100L2/150L2 IP10:SV3-200L2/300L2/500L2
Allowable frequency fluctuation / Main circuit/control circuit
±5% max.
Power supply/current capacity and power loss / Main circuit power supply
Three-phase 200 V/Single-phase 200 V/DC 270 V

Compatibility Information

Match SV3-075L2 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing SV3-075L2.

Maintenance Tips

Store SV3-075L2 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.