+86 13348028050
SR3XT141FU Schneider Electric SR3XT141FU - Front View | Vcocnc FANUC Parts

Schneider Electric SR3XT141FU

Product information

SKU: SR3XT141FU

Alternate: SR3XT141FU

Brand
Schneider Electric
Part No.
SR3XT141FU
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric SR3XT141FU Product overview The Schneider Electric SR3XT141FU is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Backup time: 10 years 77 °F (25 °C) - Characteristic: Value(s) - Checks: Program memory on each power up - Clock drift: 12 min/year 32…131 °F (0…55 °C) - Connections - terminals: Screw terminals, 1 x 0.25...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.25...2 x 0.75 mm² AWG 24...AWG 18) flexible with cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) solid Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid - Contacts type and composition: NO relay output - Current state 0 guaranteed: <= 0.5 mA discrete input) - Current state 1 guaranteed: >= 0.17 mA discrete input) - Cycle time: 6…90 ms - Discrete input current: 0.6 mA - Discrete input frequency: 57...63 Hz 47...53 Hz - Discrete input number: 8 - Discrete input voltage: 100...240 V AC - Electrical durability: AC-15 500000 cycles 230 V, 0.9 A relay output IEC 60947-5-1 AC-12 500000 cycles 230 V, 1.5 A relay output IEC 60947-5-1 DC-13 500000 cycles 24 V, 0.6 A relay output IEC 60947-5-1 DC-12 500000 cycles 24 V, 1.5 A relay output IEC 60947-5-1 - Input impedance: 350 kOhm discrete input - Mechanical durability: 10000000 cycles relay output - Number of Outputs: 6 relay - Number or control scheme lines: 120 ladder - Operating rate in Hz: 0.1 Hz at Ie)relay output 10 Hz no load)relay output - Output thermal current: 5 A for 2 outputs relay output 8 A for 4 outputs relay output - Output voltage limits: 5...30 V DC relay output) 24...250 V AC - Overvoltage category: III conforming to IEC 60664-1 - Product Weight: 0.49 lb(US) (0.22 kg) - Product or Component Type: Discrete I/O extension module - Range of Product: Zelio Logic - Response time: 50 ms ladder from state 0 to state 1)discrete input 50 ms ladder from state 1 to state 0)discrete input 50...255 ms FBD from state 0 to state 1)discrete input 50...255 ms FBD from state 1 to state 0)discrete input 10 ms from state 0 to state 1)relay output 5 ms from state 1 to state 0)relay output - Reverse polarity protection: With - Supply frequency: 50/60 Hz - Supply voltage limits: 85…264 V - Switching capacity in mA: >= 10 mA 12 V relay output) - Tightening torque: 4.4 lbf.in (0.5 N.m) - Voltage state 0 guaranteed: <= 40 V discrete input - Voltage state 1 guaranteed: >= 79 V discrete input - [Uimp] rated impulse withstand voltage: 4 kV EN/IEC 60947-1 and EN/IEC 60664-1 - [Us] rated supply voltage: 100...240 V AC Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number SR3XT141FU with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
SR3XT141FU
Brand
Schneider Electric
Part Number
SR3XT141FU
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Checks
Program memory on each power up
Cycle time
6…90 ms
Backup time
10 years 77 °F (25 °C)
Clock drift
12 min/year 32…131 °F (0…55 °C)
Response time
50 ms ladder from state 0 to state 1)discrete input 50 ms ladder from state 1 to state 0)discrete input 50...255 ms FBD from state 0 to state 1)discrete input 50...255 ms FBD from state 1 to state 0)discrete input 10 ms from state 0 to state 1)relay output 5 ms from state 1 to state 0)relay output
Characteristic
Value(s)
Product Weight
0.49 lb(US) (0.22 kg)
Input impedance
350 kOhm discrete input
Range of Product
Zelio Logic
Supply frequency
50/60 Hz
Number of Outputs
6 relay
Tightening torque
4.4 lbf.in (0.5 N.m)
Operating rate in Hz
0.1 Hz at Ie)relay output 10 Hz no load)relay output
Overvoltage category
III conforming to IEC 60664-1
Discrete input number
8
Electrical durability
AC-15 500000 cycles 230 V, 0.9 A relay output IEC 60947-5-1 AC-12 500000 cycles 230 V, 1.5 A relay output IEC 60947-5-1 DC-13 500000 cycles 24 V, 0.6 A relay output IEC 60947-5-1 DC-12 500000 cycles 24 V, 1.5 A relay output IEC 60947-5-1
Mechanical durability
10000000 cycles relay output
Output voltage limits
5...30 V DC relay output) 24...250 V AC
Supply voltage limits
85…264 V
Discrete input current
0.6 mA
Discrete input voltage
100...240 V AC
Output thermal current
5 A for 2 outputs relay output 8 A for 4 outputs relay output
Connections - terminals
Screw terminals, 1 x 0.25...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.25...2 x 0.75 mm² AWG 24...AWG 18) flexible with cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) solid Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid
Discrete input frequency
57...63 Hz 47...53 Hz
Switching capacity in mA
>= 10 mA 12 V relay output)
Product or Component Type
Discrete I/O extension module
[Us] rated supply voltage
100...240 V AC
Current state 0 guaranteed
<= 0.5 mA discrete input)
Current state 1 guaranteed
>= 0.17 mA discrete input)
Voltage state 0 guaranteed
<= 40 V discrete input
Voltage state 1 guaranteed
>= 79 V discrete input
Reverse polarity protection
With
Contacts type and composition
NO relay output
Number or control scheme lines
120 ladder
[Uimp] rated impulse withstand voltage
4 kV EN/IEC 60947-1 and EN/IEC 60664-1

Compatibility Information

Match SR3XT141FU against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing SR3XT141FU.

Maintenance Tips

Store SR3XT141FU dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options