+86 13348028050
SL-V79FM-R KEYENCE SL-V79FM-R - Front View | Vcocnc FANUC Parts

KEYENCE SL-V79FM-R

Product information

SKU: SL-V79FM-R

Alternate: SLV79FMR

Brand
KEYENCE
Part No.
SL-V79FM-R
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE SL-V79FM-R Product overview The KEYENCE SL-V79FM-R is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Ambient light: Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max. - Approved standards / EMC: EMS IEC61496-1, EN61496-1, UL61496-1 - Beam axis spacing/Lens diameter: 10 mm/ø4 mm 0.39"/ø0.16" - Current consumption (mA) / When the center indicator is ON: Transmitter 142 *6 - Detection capability: ø0.55" ø14 mm - EMI: EN55011 Class A, FCC Part15B Class A - Effective aperture angle: Max. ±2.5 ° (When operating distance is 3 m 98.23' or more) - Environmental resistance / Enclosure rating: IP65/67 (IEC60529) - Front cover: Polycarbonate, SUS304 - Input / EDM input: Short-circuit current 10 mA - Leakage current: Max. 100 µA *3 - Light source: Infrared LED (850 nm) - Load wiring resistance: Max. 2.5 Ω *4 - Material / Main unit case: Aluminum - Max. capacitive load: 2.2 µF (with a load resistance of 100 Ω) - Max. l oad current: 500 mA *2 - Muting lamp output: Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA) *5 can be connected - Non safety-rel ated output / AUX: Output with automatic PNP/NPN switching function, 50 mA max. - OFF→ON: 56.8 *1 - OSSD output / Output: 2 outputs each for PNP and NPN. Can be changed by using the connector cable. - Operating ambient temperature: -10 to +55 °C 14 to 131 °F (No freezing) - Operating relative humidity: 15 to 85 % RH (No condensation) - Operation mode: Turns on when no interruptions are present in the detection zone (excluding when the muting function is used) - Overvoltage category: II - Protection circuit: Reverse current protection, short-circuit protection for each output, surge protection for each output - Rating / Power voltage: 24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less - Receiver: 94 *6 - Residual vol tage (during ON): Max. 2.5 V (with a cable length of 7 m 22.97' ) - Response time (ms) / ON→OFF: 16.8 *1 - Safety: IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD) IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe) UL508 UL1998 - Shock resistance: 100 m/s 2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions - Storage relative humidity: 15 to 95 % RH - Storage temperature: -25 to +60 °C -13 to 140 °F (No freezing) - Upper case/lower case: Zinc die-cast - Vibration resistance: 10 to 55 Hz, Double amplitude 0.7 mm 0.03" , 20 sweeps in each of the X, Y, and Z directions - Wait input: Short-circuit current 2.5 mA - Weight / Transmitter: 1,760 g - When the center indicator is OFF / Transmitter: 135 *6 - Working distance: 0.1 to 7 m Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number SL-V79FM-R with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
SL-V79FM-R
Brand
KEYENCE
Part Number
SL-V79FM-R
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
EMI
EN55011 Class A, FCC Part15B Class A
Safety
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD) IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe) UL508 UL1998
OFF→ON
56.8 *1
Receiver
94 *6
Wait input
Short-circuit current 2.5 mA
Front cover
Polycarbonate, SUS304
Light source
Infrared LED (850 nm)
Ambient light
Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.
Operation mode
Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)
Leakage current
Max. 100 µA *3
Shock resistance
100 m/s 2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Working distance
0.1 to 7 m
Input / EDM input
Short-circuit current 10 mA
Max. l oad current
500 mA *2
Muting lamp output
Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA) *5 can be connected
Protection circuit
Reverse current protection, short-circuit protection for each output, surge protection for each output
Storage temperature
-25 to +60 °C -13 to 140 °F (No freezing)
Detection capability
ø0.55" ø14 mm
Max. capacitive load
2.2 µF (with a load resistance of 100 Ω)
OSSD output / Output
2 outputs each for PNP and NPN. Can be changed by using the connector cable.
Overvoltage category
II
Vibration resistance
10 to 55 Hz, Double amplitude 0.7 mm 0.03" , 20 sweeps in each of the X, Y, and Z directions
Weight / Transmitter
1,760 g
Upper case/lower case
Zinc die-cast
Load wiring resistance
Max. 2.5 Ω *4
Rating / Power voltage
24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less
Approved standards / EMC
EMS IEC61496-1, EN61496-1, UL61496-1
Effective aperture angle
Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)
Material / Main unit case
Aluminum
Storage relative humidity
15 to 95 % RH
Operating relative humidity
15 to 85 % RH (No condensation)
Operating ambient temperature
-10 to +55 °C 14 to 131 °F (No freezing)
Residual vol tage (during ON)
Max. 2.5 V (with a cable length of 7 m 22.97' )
Response time (ms) / ON→OFF
16.8 *1
Beam axis spacing/Lens diameter
10 mm/ø4 mm 0.39"/ø0.16"
Non safety-rel ated output / AUX
Output with automatic PNP/NPN switching function, 50 mA max.
Environmental resistance / Enclosure rating
IP65/67 (IEC60529)
When the center indicator is OFF / Transmitter
135 *6
Current consumption (mA) / When the center indicator is ON
Transmitter 142 *6

Compatibility Information

Match SL-V79FM-R against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing SL-V79FM-R.

Maintenance Tips

Store SL-V79FM-R dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114