KEYENCE SJ-Q228
Product information
SKU: SJ-Q228
Alternate: SJQ228
Brand
KEYENCE
Part No.
SJ-Q228
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
KEYENCE SJ-Q228
Product overview
The KEYENCE SJ-Q228 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Air connection port: Rc1/8
- Air supply pressure: 0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI ) *4
- Average power consumption: Normal operation: 8.4 W, LPC mode: 4.1 W *3
- Clean rating: ISO14644-1 Class 3 *2
- Communication functions: Remote control
- Control input / Static elimination stop input: NPN open collector or non-voltage contact signal
- Control output / Ion level warning, condition warning, alarm output: NPN open collector Maximum 100 mA (40 VDC or less)
- Current consumption: Normal operation: 700 mA or less, LPC mode: 170 mA (typical) *3
- Effective length: 2360 mm 92.91" *5
- Environmental resistance / Ambient temperature: 0 to +40°C 32 to 104°F
- Installation distance: 10 mm 0.39" or more
- Ion balance: ±3 V *1
- Ion balance control method: Hi-Power I.C.C. method
- Ion generation method: Corona discharge method
- Main body: ABS/PBT/PP/LCP/PPS/SPS/SUS
- Major functions: Condition alarm, ion level alarm, alarm output
- Material / Electrode probe: Tungsten
- No. ofelectrodes: 37
- Overvoltage category: I
- Pollution degree: 2
- Rating / Power voltage: 24 to 36 VDC±10%
- Relative humidity: 85% RH or less (no condensation)
- Structure: Shockless resistive coupling type
- Total length: 2240 mm 88.19"
- Voltage application method / Applied voltage: Pulse AC method/±8000 Vmax
- Weight: 2440 g 86.13 oz
Condition and supply
- Price on request: send an inquiry with the quantity you need
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number SJ-Q228 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- SJ-Q228
- Brand
- KEYENCE
- Part Number
- SJ-Q228
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Weight
- 2440 g 86.13 oz
- Main body
- ABS/PBT/PP/LCP/PPS/SPS/SUS
- Structure
- Shockless resistive coupling type
- Ion balance
- ±3 V *1
- Clean rating
- ISO14644-1 Class 3 *2
- Total length
- 2240 mm 88.19"
- Major functions
- Condition alarm, ion level alarm, alarm output
- Effective length
- 2360 mm 92.91" *5
- No. ofelectrodes
- 37
- Pollution degree
- 2
- Relative humidity
- 85% RH or less (no condensation)
- Air connection port
- Rc1/8
- Air supply pressure
- 0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI ) *4
- Current consumption
- Normal operation: 700 mA or less, LPC mode: 170 mA (typical) *3
- Overvoltage category
- I
- Installation distance
- 10 mm 0.39" or more
- Ion generation method
- Corona discharge method
- Rating / Power voltage
- 24 to 36 VDC±10%
- Communication functions
- Remote control
- Average power consumption
- Normal operation: 8.4 W, LPC mode: 4.1 W *3
- Ion balance control method
- Hi-Power I.C.C. method
- Material / Electrode probe
- Tungsten
- Voltage application method / Applied voltage
- Pulse AC method/±8000 Vmax
- Control input / Static elimination stop input
- NPN open collector or non-voltage contact signal
- Environmental resistance / Ambient temperature
- 0 to +40°C 32 to 104°F
- Control output / Ion level warning, condition warning, alarm output
- NPN open collector Maximum 100 mA (40 VDC or less)
Compatibility Information
Match SJ-Q228 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing SJ-Q228.
Maintenance Tips
Store SJ-Q228 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. SJ-Q228 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
SJ-Q228 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match SJ-Q228 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114