Product Description

KEYENCE SC-S11 Product overview The KEYENCE SC-S11 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Approved standards / EMC: EMS IEC 61496-1, EN61496-1, UL61496-1 - Current consumption: 1.3 A (at maximum load) - EMI: EN55011 Class A, FCC Part 15 Class A, ICES-003 Issue 4 Class A - Environmental resistance / Enclosure rating: IP20 (IEC60529) Must be installed within a control panel rated at IP54 or higher. - Insulation resistance: 100 MΩ or more (tested with a 500 VDC megger) between the internal circuit and the external case - Leakage current: 1.2 mA maximum - Load wiring length: 30 m maximum - Material / Main unit case: Polycarbonate (UL94-V2) - Max. capacitive load: 2.2 µF (with a load resistance of 100 Ω) - Max. load current: 500 mA - Non-safety input / Input type: No-voltage contact input or PNP or NPN open-collector input (external off input) - Non-safety output / Output: PNP/NPN totem pole output (auxiliary output, lockout output) - ON/OFF voltage: Voltage when product turned on: 19 V or more, voltage when product turned off: 5 V or less - Operating ambient temperature: -10 to +55 °C 14 to 131 °F (No freezing) - Operating relative humidity: 35 to 85 % RH (No condensation) - Overvoltage category: 2 (IEC60664, EN50178) - Pollution degree: 2 (IEC60664/EN50178) - Protection circuit: Power supply reverse polarity protection, overcurrent protection for each output, short-circuit protection , surge protection - Rating / Power voltage: 24 VDC ±10 %, Ripple (P-P) 10 % or less - Residual voltage (when ON): 2.5 V maximum (with a load current of 500 mA) - Response time: 25 ms (safety output ON to OFF, IEC/EN60204-1 stop category 0), 70 ms (safety output OFF to ON) - Safety: ISO13849-1:2015 (category 4, PLe), UL1998, IEC/EN61496-1, UL508, *1 - Safety input (S-INPUT, enable input) / Input type: Contact output device connection or PNP output device connection - Safety output (S-OUTPUT) / Output: Two PNP outputs - Safety related input / Input type: Non-voltage contact input (EDM input, reset input) - Shock resistance: 100 m/s 2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions - Short-circuit current: Approx 5mA - Storage relative humidity: 35 to 85 % RH - Storage temperature: -20 to +65 °C -4 to 149 °F (No freezing) - Vibration resistance: 10 to 55 Hz, Double amplitude 0.7 mm 0.03" , 20 sweeps in each of the X, Y, and Z directions - Weight: 160 g or less - Wiring length: 30 m maximum - Withstand voltage: 1,500 VAC, 50/60 Hz for 1 minute between the internal circuit and the external case Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number SC-S11 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
SC-S11
Brand
KEYENCE
Part Number
SC-S11
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
EMI
EN55011 Class A, FCC Part 15 Class A, ICES-003 Issue 4 Class A
Safety
ISO13849-1:2015 (category 4, PLe), UL1998, IEC/EN61496-1, UL508, *1
Weight
160 g or less
Packaging
New surplus, factory sealed original packaging
Response time
25 ms (safety output ON to OFF, IEC/EN60204-1 stop category 0), 70 ms (safety output OFF to ON)
Wiring length
30 m maximum
ON/OFF voltage
Voltage when product turned on: 19 V or more, voltage when product turned off: 5 V or less
Leakage current
1.2 mA maximum
Pollution degree
2 (IEC60664/EN50178)
Shock resistance
100 m/s 2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Max. load current
500 mA
Withstand voltage
1,500 VAC, 50/60 Hz for 1 minute between the internal circuit and the external case
Load wiring length
30 m maximum
Protection circuit
Power supply reverse polarity protection, overcurrent protection for each output, short-circuit protection , surge protection
Current consumption
1.3 A (at maximum load)
Storage temperature
-20 to +65 °C -4 to 149 °F (No freezing)
Max. capacitive load
2.2 µF (with a load resistance of 100 Ω)
Overvoltage category
2 (IEC60664, EN50178)
Vibration resistance
10 to 55 Hz, Double amplitude 0.7 mm 0.03" , 20 sweeps in each of the X, Y, and Z directions
Insulation resistance
100 MΩ or more (tested with a 500 VDC megger) between the internal circuit and the external case
Short-circuit current
Approx 5mA
Rating / Power voltage
24 VDC ±10 %, Ripple (P-P) 10 % or less
Approved standards / EMC
EMS IEC 61496-1, EN61496-1, UL61496-1
Material / Main unit case
Polycarbonate (UL94-V2)
Storage relative humidity
35 to 85 % RH
Non-safety output / Output
PNP/NPN totem pole output (auxiliary output, lockout output)
Residual voltage (when ON)
2.5 V maximum (with a load current of 500 mA)
Operating relative humidity
35 to 85 % RH (No condensation)
Non-safety input / Input type
No-voltage contact input or PNP or NPN open-collector input (external off input)
Operating ambient temperature
-10 to +55 °C 14 to 131 °F (No freezing)
Safety output (S-OUTPUT) / Output
Two PNP outputs
Safety related input / Input type
Non-voltage contact input (EDM input, reset input)
Environmental resistance / Enclosure rating
IP20 (IEC60529) Must be installed within a control panel rated at IP54 or higher.
Safety input (S-INPUT, enable input) / Input type
Contact output device connection or PNP output device connection

Compatibility Information

Match SC-S11 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing SC-S11.

Maintenance Tips

Store SC-S11 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114