+86 13348028050
RM4JA32MW Schneider Electric RM4JA32MW - Front View | Vcocnc FANUC Parts

Schneider Electric RM4JA32MW

Product information

SKU: RM4JA32MW

Alternate: RM4JA32MW

Brand
Schneider Electric
Part No.
RM4JA32MW
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric RM4JA32MW Product overview The Schneider Electric RM4JA32MW is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Connections - terminals: Screw terminals, 2 x 1.5 mm²flexible with cable end Screw terminals, 2 x 2.5 mm²flexible without cable end - Contacts material: 90/10 silver nickel contacts - Contacts type and composition: 2 C/O - Depth: 3.1 in (80 mm) - Hysteresis: 5…30 % adjustable current threshold setting - Internal input resistance: 0.06 Ohm 0.006 Ohm 0.02 Ohm - Marking: CE : EMC 89/336/EEC CE : LVD 73/23/EEC - Maximum measuring cycle: 80 ms - Maximum power consumption in VA: 3.3 VA AC - Maximum power consumption in W: 1.2 W DC - Maximum switching voltage: 440 V AC - Measurement range: 1...5 A current AC 1...5 A current DC 3...15 A current AC 3...15 A current DC 300...1500 mA current AC 300...1500 mA current DC - Mechanical durability: 30000000 cycles - Number of cables: 2 - Operating position: Any position without derating - Output contacts: 2 C/O - Overvoltage category: III conforming to IEC 60664-1 - Permissible continuous overload: 7 A 20 A 2 A - Permissible non repetitive overload: 10 A <= 3 s 100 A 15 A - Product or Component Type: Industrial measurement and control relays - Range of Product: Harmony Relay - Relay Type: Current measurement relay - Relay monitored parameters: Overcurrent or undercurrent detection - Relay name: RM4J - Setting accuracy of the switching threshold: +/-5 % - Setting accuracy of time delay: 10 P - Supply disconnection value: > 0.1 Uc - Switching capacity in mA: 10 mA 12 V - Switching threshold drift: <= 0.06 % per degree centigrade depending permissible ambient air temperature <= 0.5 % within the supply voltage range (0.85...1.1 Un) - Switching voltage: 250 V AC - Terminals description ISO n°1: (C-B1-B2-B3)CO (25-26-28)OC (A1-A2)CO (15-16-18)OC - Tightening torque: 5.3…9.7 lbf.in (0.6…1.1 N.m) - Time delay drift: <= 0.07 % per degree centigrade depending on temperature <= 0.5 % within the supply voltage range (0.85...1.1 Un) - Width: 1.8 in (45 mm) - [Ie] rated operational current: 2 A 24 V DC-13 158 °F (70 °C) IEC 60947-5-1/1991 2 A 24 V DC-13 158 °F (70 °C) VDE 0660 3 A 115 V AC-15 158 °F (70 °C) IEC 60947-5-1/1991 3 A 115 V AC-15 158 °F (70 °C) VDE 0660 3 A 24 V AC-15 158 °F (70 °C) IEC 60947-5-1/1991 3 A 24 V AC-15 158 °F (70 °C) VDE 0660 3 A 250 V AC-15 158 °F (70 °C) IEC 60947-5-1/1991 3 A 250 V AC-15 158 °F (70 °C) VDE 0660 0.1 A 250 V DC-13 158 °F (70 °C) IEC 60947-5-1/1991 0.1 A 250 V DC-13 158 °F (70 °C) VDE 0660 0.3 A 115 V DC-13 158 °F (70 °C) IEC 60947-5-1/1991 0.3 A 115 V DC-13 158 °F (70 °C) VDE 0660 - [Ith] conventional free air thermal current: 8 A - [Ui] rated insulation voltage: 500 V IEC - operating voltage tolerance: 0.85...1.1 Uc - time delay: Adjustable 0.05...30 s Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number RM4JA32MW with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
RM4JA32MW
Brand
Schneider Electric
Part Number
RM4JA32MW
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Depth
3.1 in (80 mm)
Width
1.8 in (45 mm)
Marking
CE : EMC 89/336/EEC CE : LVD 73/23/EEC
Hysteresis
5…30 % adjustable current threshold setting
Relay Type
Current measurement relay
Relay name
RM4J
time delay
Adjustable 0.05...30 s
Characteristic
Value(s)
Output contacts
2 C/O
Number of cables
2
Range of Product
Harmony Relay
Time delay drift
<= 0.07 % per degree centigrade depending on temperature <= 0.5 % within the supply voltage range (0.85...1.1 Un)
Contacts material
90/10 silver nickel contacts
Measurement range
1...5 A current AC 1...5 A current DC 3...15 A current AC 3...15 A current DC 300...1500 mA current AC 300...1500 mA current DC
Switching voltage
250 V AC
Tightening torque
5.3…9.7 lbf.in (0.6…1.1 N.m)
Operating position
Any position without derating
Overvoltage category
III conforming to IEC 60664-1
Mechanical durability
30000000 cycles
Connections - terminals
Screw terminals, 2 x 1.5 mm²flexible with cable end Screw terminals, 2 x 2.5 mm²flexible without cable end
Maximum measuring cycle
80 ms
Switching capacity in mA
10 mA 12 V
Internal input resistance
0.06 Ohm 0.006 Ohm 0.02 Ohm
Maximum switching voltage
440 V AC
Product or Component Type
Industrial measurement and control relays
Switching threshold drift
<= 0.06 % per degree centigrade depending permissible ambient air temperature <= 0.5 % within the supply voltage range (0.85...1.1 Un)
Relay monitored parameters
Overcurrent or undercurrent detection
Supply disconnection value
> 0.1 Uc
operating voltage tolerance
0.85...1.1 Uc
Contacts type and composition
2 C/O
[Ui] rated insulation voltage
500 V IEC
Maximum power consumption in W
1.2 W DC
Setting accuracy of time delay
10 P
[Ie] rated operational current
2 A 24 V DC-13 158 °F (70 °C) IEC 60947-5-1/1991 2 A 24 V DC-13 158 °F (70 °C) VDE 0660 3 A 115 V AC-15 158 °F (70 °C) IEC 60947-5-1/1991 3 A 115 V AC-15 158 °F (70 °C) VDE 0660 3 A 24 V AC-15 158 °F (70 °C) IEC 60947-5-1/1991 3 A 24 V AC-15 158 °F (70 °C) VDE 0660 3 A 250 V AC-15 158 °F (70 °C) IEC 60947-5-1/1991 3 A 250 V AC-15 158 °F (70 °C) VDE 0660 0.1 A 250 V DC-13 158 °F (70 °C) IEC 60947-5-1/1991 0.1 A 250 V DC-13 158 °F (70 °C) VDE 0660 0.3 A 115 V DC-13 158 °F (70 °C) IEC 60947-5-1/1991 0.3 A 115 V DC-13 158 °F (70 °C) VDE 0660
Maximum power consumption in VA
3.3 VA AC
Permissible continuous overload
7 A 20 A 2 A
Terminals description ISO n°1
(C-B1-B2-B3)CO (25-26-28)OC (A1-A2)CO (15-16-18)OC
Permissible non repetitive overload
10 A <= 3 s 100 A 15 A
Setting accuracy of the switching threshold
+/-5 %
[Ith] conventional free air thermal current
8 A

Compatibility Information

Match RM4JA32MW against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing RM4JA32MW.

Maintenance Tips

Store RM4JA32MW dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options