Product Description

Schneider Electric RM35TF30 Product overview The Schneider Electric RM35TF30 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Adjustment of asymmetry threshold: 5...15 % of Un selected - Characteristic: Value(s) - Connections - terminals: Screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end - Contacts type and composition: 2 C/O - Control circuit frequency: 50...60 Hz +/- 10 % - Control circuit voltage limits: - 12 % + 10 % Un - Hysteresis: 2 % - Insulation resistance: > 500 MOhm 500 V DC IEC 60255-5 > 500 MOhm 500 V DC IEC 60664-1 - Maximum measuring cycle: 140 ms measurement cycle as true rms value - Maximum switching current: 5 A AC 5 A DC - Maximum switching voltage: 250 V AC 250 V DC - Measurement error: < 1 % over the whole range with voltage variation 0.05 %/°C with temperature variation - Measurement range: 220...480 V AC - Measurement voltage limits: 176…528 V AC - Minimum switching current: 10 mA 5 V DC - Operating position: Any position without derating - Output contacts: 2 C/O - Power consumption in VA: 0…22 VA 400 V AC 50 Hz - Product Specific Application: For 3-phase supply - Product or Component Type: 3-phase control relay - Range of Product: Harmony Control Relays - Relay Type: Multifunction control relay - Relay monitored parameters: Undervoltage and overvoltage in window mode Phase sequence Phase failure detection Asymmetry - Relay name: RM35TF - Repeat accuracy: 0.3 % time delay 0.5 % input and measurement circuit - Reset time: 1500 ms at 480 V - Response time: < 200 ms (in the event of a fault) - Supply frequency: 50/60 Hz +/- 10 % - Supply voltage limits: 194…528 V AC, 3 phase - Switching capacity in VA: 1250 VA - Threshold adjustment voltage: 2...20 % of Un selected -12...-2 % in the range 220 V AC +2...+10 % in the range 480 V AC - Tightening torque: 5.3…8.9 lbf.in (0.6…1 N.m) IEC 60947-1 - Voltage detection threshold: < 194 V - Voltage range: 220...480 V phase to phase - [Uc] control circuit voltage: 220...480 V - [Ui] rated insulation voltage: 400 V IEC 60664-1 - [Un] rated nominal voltage: , self-powered - delay at power up: 650 ms - nominal output current: 5 A - time delay: Adjustable 0.1...10 s, +/- 10 % of the full scale value Tt- time delay upon fault Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number RM35TF30 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
RM35TF30
Brand
Schneider Electric
Part Number
RM35TF30
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Packaging
New surplus, factory sealed original packaging
Hysteresis
2 %
Relay Type
Multifunction control relay
Relay name
RM35TF
Reset time
1500 ms at 480 V
time delay
Adjustable 0.1...10 s, +/- 10 % of the full scale value Tt- time delay upon fault
Response time
< 200 ms (in the event of a fault)
Voltage range
220...480 V phase to phase
Characteristic
Value(s)
Output contacts
2 C/O
Repeat accuracy
0.3 % time delay 0.5 % input and measurement circuit
Range of Product
Harmony Control Relays
Supply frequency
50/60 Hz +/- 10 %
Measurement error
< 1 % over the whole range with voltage variation 0.05 %/°C with temperature variation
Measurement range
220...480 V AC
Tightening torque
5.3…8.9 lbf.in (0.6…1 N.m) IEC 60947-1
delay at power up
650 ms
Operating position
Any position without derating
Insulation resistance
> 500 MOhm 500 V DC IEC 60255-5 > 500 MOhm 500 V DC IEC 60664-1
Supply voltage limits
194…528 V AC, 3 phase
nominal output current
5 A
Connections - terminals
Screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
Maximum measuring cycle
140 ms measurement cycle as true rms value
Power consumption in VA
0…22 VA 400 V AC 50 Hz
Switching capacity in VA
1250 VA
Control circuit frequency
50...60 Hz +/- 10 %
Maximum switching current
5 A AC 5 A DC
Maximum switching voltage
250 V AC 250 V DC
Minimum switching current
10 mA 5 V DC
Product or Component Type
3-phase control relay
Measurement voltage limits
176…528 V AC
Relay monitored parameters
Undervoltage and overvoltage in window mode Phase sequence Phase failure detection Asymmetry
[Un] rated nominal voltage
, self-powered
Voltage detection threshold
< 194 V
Product Specific Application
For 3-phase supply
Threshold adjustment voltage
2...20 % of Un selected -12...-2 % in the range 220 V AC +2...+10 % in the range 480 V AC
[Uc] control circuit voltage
220...480 V
Contacts type and composition
2 C/O
[Ui] rated insulation voltage
400 V IEC 60664-1
Control circuit voltage limits
- 12 % + 10 % Un
Adjustment of asymmetry threshold
5...15 % of Un selected

Compatibility Information

Match RM35TF30 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing RM35TF30.

Maintenance Tips

Store RM35TF30 dry and dust-free in its packaging until installation.