+86 13348028050
RE7ML11BU Schneider Electric RE7ML11BU - Front View | Vcocnc FANUC Parts

Schneider Electric RE7ML11BU

Product information

SKU: RE7ML11BU

Alternate: RE7ML11BU

Brand
Schneider Electric
Part No.
RE7ML11BU
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric RE7ML11BU Product overview The Schneider Electric RE7ML11BU is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Component name: RE7 - Connections - terminals: Screw terminals, 2 x 1.5 mm² flexible with cable end Screw terminals, 2 x 2.5 mm² flexible without cable end - Contacts material: 90/10 silver nickel contacts - Depth: 3.1 in (80 mm) - Discrete output type: Relay - Height: 3.07 in (78 mm) - Input compatibility: 3/4 wires sensors PNP/NPN without internal load <164.04 ft (50 m) X1Z2 3/4 wires sensors PNP/NPN without internal load <164.04 ft (50 m) Y1Z2 - Input voltage: < 60 V X1Z2 < 60 V Y1Z2 - Marking: CE - Maximum [Ie] rated operational current: 2 A DC-13 24 V 158 °F (70 °C) IEC 60947-5-1/1991/VDE 0660 0.1 A DC-13 250 V 158 °F (70 °C) IEC 60947-5-1/1991/VDE 0660 0.2 A DC-13 115 V 158 °F (70 °C) IEC 60947-5-1/1991/VDE 0660 3 A AC-15 158 °F (70 °C) IEC 60947-5-1/1991/VDE 0660 - Maximum power consumption in W: 0.5 W 24 V 1.2 W 48 V - Maximum switching current: 1 mA X1Z2) 1 mA Y1Z2) - Maximum switching voltage: 250 V AC/DC - Mechanical durability: 20000000 cycles - Minimum pulse duration: 20 ms - Minimum switching capacity: 10 mA 12 V - Operating position: Any position without derating - Overvoltage category: III conforming to IEC 60664-1 - Potentiometer characteristic: Linear 47 kOhm +/- 20 %), 0.2 W 82.02 ft (25 m) Z1Z2 - Power consumption in VA: 0.7 VA 24 V 1.6 VA 48 V 1.8 VA 110 V 8.5 VA 240 V - Product or Component Type: Industrial timing relay - Range of Product: Zelio Time - Repeat accuracy: +/- 0.2 % - Reset time: 50 ms - Setting accuracy of time delay: +/- 10 % of full scale - Supply disconnection value: > 0.1 Uc - Surge withstand: 2 kV IEC 61000-4-5 level 3 - Temperature Drift: < 0.07 %/°C - Terminal description: (Y1)UNUSED (15-16-18)OC (Z1)UNUSED (Z2)UNUSED (B1-A2)CO ALT (X1)UNUSED - Tightening torque: 5.3…9.7 lbf.in (0.6…1.1 N.m) - Time delay range: 0.05 s...300 h - Time delay type: Di D W C A H - Voltage drift: < 0.2 %/V - Voltage range: 0.85...1.1 Us - Width: 0.9 in (22.5 mm) - Width pitch dimension: 0.9 in (22.5 mm) - [Ith] conventional free air thermal current: 8 A - [Ui] rated insulation voltage: 250 V between contact circuit and control inputs IEC 250 V between contact circuit and power supply IEC 300 V between contact circuit and control inputs CSA 300 V between contact circuit and power supply CSA - [Us] rated supply voltage: 110...240 V AC 50/60 Hz 24 V AC/DC 50/60 Hz 42...48 V AC/DC 50/60 Hz Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number RE7ML11BU with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
RE7ML11BU
Brand
Schneider Electric
Part Number
RE7ML11BU
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Depth
3.1 in (80 mm)
Width
0.9 in (22.5 mm)
Height
3.07 in (78 mm)
Marking
CE
Reset time
50 ms
Input voltage
< 60 V X1Z2 < 60 V Y1Z2
Voltage drift
< 0.2 %/V
Voltage range
0.85...1.1 Us
Characteristic
Value(s)
Component name
RE7
Repeat accuracy
+/- 0.2 %
Surge withstand
2 kV IEC 61000-4-5 level 3
Time delay type
Di D W C A H
Range of Product
Zelio Time
Time delay range
0.05 s...300 h
Contacts material
90/10 silver nickel contacts
Temperature Drift
< 0.07 %/°C
Tightening torque
5.3…9.7 lbf.in (0.6…1.1 N.m)
Operating position
Any position without derating
Input compatibility
3/4 wires sensors PNP/NPN without internal load <164.04 ft (50 m) X1Z2 3/4 wires sensors PNP/NPN without internal load <164.04 ft (50 m) Y1Z2
Discrete output type
Relay
Overvoltage category
III conforming to IEC 60664-1
Terminal description
(Y1)UNUSED (15-16-18)OC (Z1)UNUSED (Z2)UNUSED (B1-A2)CO ALT (X1)UNUSED
Mechanical durability
20000000 cycles
Width pitch dimension
0.9 in (22.5 mm)
Minimum pulse duration
20 ms
Connections - terminals
Screw terminals, 2 x 1.5 mm² flexible with cable end Screw terminals, 2 x 2.5 mm² flexible without cable end
Power consumption in VA
0.7 VA 24 V 1.6 VA 48 V 1.8 VA 110 V 8.5 VA 240 V
Maximum switching current
1 mA X1Z2) 1 mA Y1Z2)
Maximum switching voltage
250 V AC/DC
Product or Component Type
Industrial timing relay
[Us] rated supply voltage
110...240 V AC 50/60 Hz 24 V AC/DC 50/60 Hz 42...48 V AC/DC 50/60 Hz
Minimum switching capacity
10 mA 12 V
Supply disconnection value
> 0.1 Uc
Potentiometer characteristic
Linear 47 kOhm +/- 20 %), 0.2 W 82.02 ft (25 m) Z1Z2
[Ui] rated insulation voltage
250 V between contact circuit and control inputs IEC 250 V between contact circuit and power supply IEC 300 V between contact circuit and control inputs CSA 300 V between contact circuit and power supply CSA
Maximum power consumption in W
0.5 W 24 V 1.2 W 48 V
Setting accuracy of time delay
+/- 10 % of full scale
Maximum [Ie] rated operational current
2 A DC-13 24 V 158 °F (70 °C) IEC 60947-5-1/1991/VDE 0660 0.1 A DC-13 250 V 158 °F (70 °C) IEC 60947-5-1/1991/VDE 0660 0.2 A DC-13 115 V 158 °F (70 °C) IEC 60947-5-1/1991/VDE 0660 3 A AC-15 158 °F (70 °C) IEC 60947-5-1/1991/VDE 0660
[Ith] conventional free air thermal current
8 A

Compatibility Information

Match RE7ML11BU against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing RE7ML11BU.

Maintenance Tips

Store RE7ML11BU dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options