KEYENCE PS-N12CP
Product information
$1,151.98 USD
Condition: newShipping calculated at checkout ( Shipping Policy · 30-Day Returns )
SKU: PS-N12CP
Alternate: PSN12CP
Brand
KEYENCE
Part No.
PS-N12CP
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
KEYENCE PS-N12CP
Product overview
The KEYENCE PS-N12CP is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Cable: PVC
- Case size: H 32.6 mm 1.28" × W 9.8 mm 0.39" × L 78.7 mm 3.1"
- Control output: PNP open collector 30 V, (without expansion) 100 mA max., (with expansion) 20 mA max, residual voltage 1.2 V max. (when the output current is 10 mA or less)/2.2 V max. (when the output current is 10 to 100 mA)
- Environmental resistance / Ambient temperature: -20 to +55 °C -4 to 131 °F (No freezing) *2
- External input: 1 input
- I/O / Control outputs: 1 output
- Main unit/Expansion unit: Expansion unit
- Material / Case: Main unit and cover material: Polycarbonate
- Number of interference prevention units: 4 for TURBO/SUPER/ULTRA/MEGA (When set to DOUBLE, the number of interference-prevention units will be doubled)
- Output: PNP
- Output selection: LIGHT-ON/DARK-ON (switch-selectable)
- Power consumption: Normal: 860 mW or less (at 30V. 30 mA max. at 24 V, 35 mA max. at 12 V) Eco on mode (ALL): 750 mW or less (at 30V. 26 mA max. at 24 V, 28 mA max. at 12 V) Eco Full mode: 540 mW or less (at 30V. 19 mA max. at 24 V, 21 mA max. at 12 V)
- Protection circuit: Reverse polarity protection, Over-current protection, Surge absorber
- Rating / Power voltage: 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS
- Relative humidity: 35 to 85 % RH (No condensation)
- Response time: 500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)
- Shock resistance: 500 m/s 2 , 3 times in each of the X, Y, and Z directions
- Timer function: Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9999 ms, Maximum error against the setting value: ±10% max.
- Type: M8 connector
- Unit expansion: Up to 16 units (Up to 17 units including 1 main unit can be connected in total.)
- Vibration resistance: 10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions
- Weight: Approx. 20 g
Condition and supply
- New surplus, never used
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number PS-N12CP with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- PS-N12CP
- Brand
- KEYENCE
- Part Number
- PS-N12CP
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Type
- M8 connector
- Cable
- PVC
- Output
- PNP
- Weight
- Approx. 20 g
- Case size
- H 32.6 mm 1.28" × W 9.8 mm 0.39" × L 78.7 mm 3.1"
- Packaging
- New surplus, never used
- Response time
- 500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)
- Control output
- PNP open collector 30 V, (without expansion) 100 mA max., (with expansion) 20 mA max, residual voltage 1.2 V max. (when the output current is 10 mA or less)/2.2 V max. (when the output current is 10 to 100 mA)
- External input
- 1 input
- Timer function
- Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9999 ms, Maximum error against the setting value: ±10% max.
- Unit expansion
- Up to 16 units (Up to 17 units including 1 main unit can be connected in total.)
- Material / Case
- Main unit and cover material: Polycarbonate
- Output selection
- LIGHT-ON/DARK-ON (switch-selectable)
- Shock resistance
- 500 m/s 2 , 3 times in each of the X, Y, and Z directions
- Power consumption
- Normal: 860 mW or less (at 30V. 30 mA max. at 24 V, 35 mA max. at 12 V) Eco on mode (ALL): 750 mW or less (at 30V. 26 mA max. at 24 V, 28 mA max. at 12 V) Eco Full mode: 540 mW or less (at 30V. 19 mA max. at 24 V, 21 mA max. at 12 V)
- Relative humidity
- 35 to 85 % RH (No condensation)
- Protection circuit
- Reverse polarity protection, Over-current protection, Surge absorber
- Vibration resistance
- 10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions
- I/O / Control outputs
- 1 output
- Rating / Power voltage
- 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS
- Main unit/Expansion unit
- Expansion unit
- Number of interference prevention units
- 4 for TURBO/SUPER/ULTRA/MEGA (When set to DOUBLE, the number of interference-prevention units will be doubled)
- Environmental resistance / Ambient temperature
- -20 to +55 °C -4 to 131 °F (No freezing) *2
Compatibility Information
Match PS-N12CP against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing PS-N12CP.
Maintenance Tips
Store PS-N12CP dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. PS-N12CP is in stock and ships within 1-2 business days, with a tracking number for every shipment.
PS-N12CP is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match PS-N12CP against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114