+86 13348028050
NR-XTH08T KEYENCE NR-XTH08T - Front View | Vcocnc FANUC Parts

KEYENCE NR-XTH08T

Product information

$3,899.92 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: NR-XTH08T

Alternate: NRXTH08T

Brand
KEYENCE
Part No.
NR-XTH08T
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE NR-XTH08T Product overview The KEYENCE NR-XTH08T is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - A/D converting system: Delta-sigma method - A/D integration time (noise filter): AUTO (Automatic configuration according to sampling cycle), 2.5 ms (400 Hz), 16.7 ms (60 Hz), 20 ms (50 Hz), 100 ms (10 Hz) - A/D resolution: 24 bits - Averaging: Switchable between ON/OFF, Averaging rate: 2 to 128 (moving average) - Buffer memory: 16M data *5 - Common mode noise reduction ratio: 135 dB or more (up to 60 Hz DC) (typ.) *4 - Display resolution: K: 0.05°C 0.09°F J: 0.05°C 0.09°F E: 0.05°C 0.09°F T: 0.01°C 0.02°F N: 0.05°C 0.09°F C: 0.05°C 0.09°F R: 0.05°C 0.09°F S: 0.05°C 0.09°F B: 0.05°C 0.09°F - Enclosure rating: IP65/IP67 (IEC 60529) Enclosure Type 4X (UL 50E, CSA C22.2 No. 94.2, NEMA 250) Indoor/outdoor use - Input connector type: Miniature thermocouple connector (Universal type) - Input impedance: 10 MΩ or more - Input method: Insulated single-end input, channels insulated from each other, input channels insulated from the case and other units (system) - Input signal source resistance: 2 kΩ or less - Input type: Thermocouple: K, J, E, T, R, S, B, N, C - Low pass filter: PASS / 200 Hz / 20 Hz - Material: Main - Maximum allowable input ground voltage: Dry locations: 30 VAC and 42.4 Vpeak, or 60 VDC Wet locations: 16 VAC and 22.6 Vpeak, or 35 VDC - Maximum input rating: ±30 V *2 - Measurable range: K: −100 to +1372°C -148°F to +2501.6°F , −200 to −100°C -328°F to -148°F J: −100 to +1200°C -148°F to +2192°F , −200 to −100°C -328°F to -148°F E: −100 to +1000°C -148°F to +1832°F , −200 to −100°C -328°F to -148°F T: −100 to +400°C -148°F to +752°F , −200 to −100°C -328°F to -148°F N: −100 to +1300°C -148°F to +2372°F , −200 to −100°C -328°F to -148°F C: 1500 to 2315°C 2732°F to 4199°F , 0 to 1500°C 32°F to 2732°F R: 300 to 1768°C 572°F to 3214.4°F , 0 to 300°C 32°F to 572°F S: 300 to 1768°C 572°F to 3214.4°F , 0 to 300°C 32°F to 572°F B: 400 to 600°C 752°F to 1112°F , 600 to 1820°C 1112°F to 3308°F - Measurement accuracy: K: ±0.04% of rdg ±0.4°C ±0.7°F , ±0.43% of rdg ±0.1°C ±0.2°F J: ±0.03% of rdg ±0.3°C ±0.5°F , ±0.30% of rdg ±0.1°C ±0.2°F E: ±0.03% of rdg ±0.3°C ±0.5°F , ±0.27% of rdg ±0.1°C ±0.2°F T: ±0.4°C ±0.7°F , ±0.34% of rdg ±0.1°C ±0.2°F N: ±0.02% of rdg ±0.6°C ±2.1°F , ±0.63% of rdg ±0.1°C ±0.2°F C: ±0.10% of rdg ±0.2°C ±0.4°F , ±0.04% of rdg ±0.8°C ±1.4°F R: ±0.01% of rdg ±1.2°C ±2.2°F , ±2.0°C ±3.6°F S: ±0.02% of rdg ±1.2°C ±2.2°F , ±2.0°C ±3.6°F B: ±2.2°C ±4.0°F , ±1.6°C ±2.9°F *4 - Measurement cycle: Maximum sampling cycle: 10 ms (100 Hz) to 1 h - Number of input channels: 8 *1 - Operating ambient humidity: Max. 100% RH *9 - Power consumption: 5.0 W max. - Power supply: Supplied from NR-X100W master unit - Reference contact compensation: Switchable between internal and external - Reference contact compensation accuracy: ±0.5°C ±0.9°F (23°C ±3°C 73.4°F ±5.4°F at input terminal temperature equilibrium) - Remote connection: Dedicated environment-resistant remote unit input port × 1 (Remote IN), output port × 1 (Remote OUT) Connection to NR-X100W master data collection unit or other NR-XR01 remote units using environment-resistant unit cable Connectable to multiple environment-resistant measurement units *6 - Shock resistance: 1000 m/s 2 3280.8 ft/s 2 - Surrounding air temperature: −40 to +85°C -40°F to +185°F *8 - Synchronization accuracy between remote connection units: ±1 μs *7 - Thermocouple burnout detection: Switchable between ON/OFF, When ON: Approx. 10 μA current detection *3 - Vibration resistance: 100 m/s 2 328.1 ft/s 2 - Warm up time: 30 minutes or more - Withstand voltage: Between measurement input terminal and case/other units (system): 1000 VAC (50 Hz / 60 Hz) for 1 minute Between measurement input terminals: 1000 VAC (50 Hz / 60 Hz) for 1 minute Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number NR-XTH08T with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
NR-XTH08T
Brand
KEYENCE
Part Number
NR-XTH08T
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Material
Main
Averaging
Switchable between ON/OFF, Averaging rate: 2 to 128 (moving average)
Packaging
New surplus, never used
Input type
Thermocouple: K, J, E, T, R, S, B, N, C
Input method
Insulated single-end input, channels insulated from each other, input channels insulated from the case and other units (system)
Power supply
Supplied from NR-X100W master unit
Warm up time
30 minutes or more
Buffer memory
16M data *5
A/D resolution
24 bits
Input impedance
10 MΩ or more
Low pass filter
PASS / 200 Hz / 20 Hz
Enclosure rating
IP65/IP67 (IEC 60529) Enclosure Type 4X (UL 50E, CSA C22.2 No. 94.2, NEMA 250) Indoor/outdoor use
Measurable range
K: −100 to +1372°C -148°F to +2501.6°F , −200 to −100°C -328°F to -148°F J: −100 to +1200°C -148°F to +2192°F , −200 to −100°C -328°F to -148°F E: −100 to +1000°C -148°F to +1832°F , −200 to −100°C -328°F to -148°F T: −100 to +400°C -148°F to +752°F , −200 to −100°C -328°F to -148°F N: −100 to +1300°C -148°F to +2372°F , −200 to −100°C -328°F to -148°F C: 1500 to 2315°C 2732°F to 4199°F , 0 to 1500°C 32°F to 2732°F R: 300 to 1768°C 572°F to 3214.4°F , 0 to 300°C 32°F to 572°F S: 300 to 1768°C 572°F to 3214.4°F , 0 to 300°C 32°F to 572°F B: 400 to 600°C 752°F to 1112°F , 600 to 1820°C 1112°F to 3308°F
Shock resistance
1000 m/s 2 3280.8 ft/s 2
Measurement cycle
Maximum sampling cycle: 10 ms (100 Hz) to 1 h
Power consumption
5.0 W max.
Remote connection
Dedicated environment-resistant remote unit input port × 1 (Remote IN), output port × 1 (Remote OUT) Connection to NR-X100W master data collection unit or other NR-XR01 remote units using environment-resistant unit cable Connectable to multiple environment-resistant measurement units *6
Withstand voltage
Between measurement input terminal and case/other units (system): 1000 VAC (50 Hz / 60 Hz) for 1 minute Between measurement input terminals: 1000 VAC (50 Hz / 60 Hz) for 1 minute
Display resolution
K: 0.05°C 0.09°F J: 0.05°C 0.09°F E: 0.05°C 0.09°F T: 0.01°C 0.02°F N: 0.05°C 0.09°F C: 0.05°C 0.09°F R: 0.05°C 0.09°F S: 0.05°C 0.09°F B: 0.05°C 0.09°F
Input connector type
Miniature thermocouple connector (Universal type)
Maximum input rating
±30 V *2
Measurement accuracy
K: ±0.04% of rdg ±0.4°C ±0.7°F , ±0.43% of rdg ±0.1°C ±0.2°F J: ±0.03% of rdg ±0.3°C ±0.5°F , ±0.30% of rdg ±0.1°C ±0.2°F E: ±0.03% of rdg ±0.3°C ±0.5°F , ±0.27% of rdg ±0.1°C ±0.2°F T: ±0.4°C ±0.7°F , ±0.34% of rdg ±0.1°C ±0.2°F N: ±0.02% of rdg ±0.6°C ±2.1°F , ±0.63% of rdg ±0.1°C ±0.2°F C: ±0.10% of rdg ±0.2°C ±0.4°F , ±0.04% of rdg ±0.8°C ±1.4°F R: ±0.01% of rdg ±1.2°C ±2.2°F , ±2.0°C ±3.6°F S: ±0.02% of rdg ±1.2°C ±2.2°F , ±2.0°C ±3.6°F B: ±2.2°C ±4.0°F , ±1.6°C ±2.9°F *4
Vibration resistance
100 m/s 2 328.1 ft/s 2
A/D converting system
Delta-sigma method
Number of input channels
8 *1
Operating ambient humidity
Max. 100% RH *9
Surrounding air temperature
−40 to +85°C -40°F to +185°F *8
Input signal source resistance
2 kΩ or less
Reference contact compensation
Switchable between internal and external
Thermocouple burnout detection
Switchable between ON/OFF, When ON: Approx. 10 μA current detection *3
Common mode noise reduction ratio
135 dB or more (up to 60 Hz DC) (typ.) *4
A/D integration time (noise filter)
AUTO (Automatic configuration according to sampling cycle), 2.5 ms (400 Hz), 16.7 ms (60 Hz), 20 ms (50 Hz), 100 ms (10 Hz)
Maximum allowable input ground voltage
Dry locations: 30 VAC and 42.4 Vpeak, or 60 VDC Wet locations: 16 VAC and 22.6 Vpeak, or 35 VDC
Reference contact compensation accuracy
±0.5°C ±0.9°F (23°C ±3°C 73.4°F ±5.4°F at input terminal temperature equilibrium)
Synchronization accuracy between remote connection units
±1 μs *7

Compatibility Information

Match NR-XTH08T against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing NR-XTH08T.

Maintenance Tips

Store NR-XTH08T dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114