KEYENCE NR-XHA08T
Product overview
The KEYENCE NR-XHA08T is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- A/D converting system: Delta-sigma method
- A/D integration time (noise filter): AUTO (Automatic configuration according to sampling cycle), 25 μs (40 kHz), 208 μs (4.8 kHz), 2.5 ms (400 Hz), 16.7 ms (60 Hz), 20 ms (50 Hz), 100 ms (10 Hz)
- A/D resolution: 24 bits
- Averaging: Switchable between ON/OFF, Averaging rate: 2 to 128 (moving average)
- Buffer memory: 16M data *3
- Common mode noise reduction ratio: 105 dB or more (up to 60 Hz DC) (typ.) *2
- Current input: Approx. 100 Ω
- Input connector type: Dedicated 3-pin connector
- Input frequency band: 2 kHz (−3 dB or more)
- Input impedance / Voltage input ±2 V range or higher: 1 MΩ ±2%
- Input method: Insulated single-end input, channels insulated from each other, input channels insulated from the case and other units (system)
- Input type: Voltage input: ±60 V, ±20 V, ±10 V, ±5 V, ±2 V, ±1 V, ±500 mV, ±200 mV, ±100 mV Current input: ±20 mA
- Maximum allowable input ground voltage: 120 VAC and 170 Vpeak, or 120 VDC (when using NR-XHA08T protective grounding) The following applies when not using NR-XHA08T protective grounding. Dry locations: 30 VAC and 42.4 Vpeak, or 60 VDC Wet locations: 16 VAC and 22.6 Vpeak, or 35 VDC
- Maximum input rating: Voltage input: ±60 V, Current input: ±30 mA
- Measurement cycle: Maximum sampling cycle: 100 μs (10 kHz) to 60 s
- Measurement range / ±60 V: Measurable range: −60.000 to +60.000 V Measurement accuracy: ±0.05% of rdg ±8 mV *2 Display resolution: 2 mV
- Number of input channels: 8 *1
- Operating ambient humidity: Max. 100% RH *7
- Power consumption: 5.8 W or less
- Power supply: Supplied from NR-X100W master unit
- Remote connection: Dedicated environment-resistant remote unit input port × 1 (Remote IN), Output port × 1 (Remote OUT) Connection to NR-X100W master data collection unit or other NR-XR01 remote units using environment-resistant unit cable Connectable to multiple environment-resistant measurement units *4
- Residual noise level: 0.005% of F.S. (typ.) when A/D integration time is set to 20 ms (50 Hz) / 16.7 ms (60 Hz) 0.05% of F.S. (typ.) when A/D integration time is set to 208 μs (4.8 kHz) *2
- Shock resistance: 1000 m/s 2 3280.8 ft/s 2
- Surrounding air temperature: −40 to +85°C -40°F to +185°F *6
- Synchronization accuracy between remote connection units: ±1 μs *5
- Vibration resistance: 100 m/s 2 328.1 ft/s 2
- Voltage input ±1 V range or higher: 10 MΩ ±2%
- Warm up time: 30 minutes or more
- Withstand voltage: Between measurement input terminal and case/other units (system): 1000 VAC (50 Hz / 60 Hz) for 1 minute Between measurement input terminals: 1000 VAC (50 Hz / 60 Hz) for 1 minute
- ±1 V: Measurable range: −1.1000 to +1.1000 V Measurement accuracy: ±0.05% of rdg ±0.2 mV *2 Display resolution: 0.05 mV
- ±10 V: Measurable range: −11.000 to +11.000 V Measurement accuracy: ±0.05% of rdg ±2 mV *2 Display resolution: 0.5 mV
- ±100 mV: Measurable range: −110.000 to +110.000 mV Measurement accuracy: ±0.05% of rdg ±0.02 mV *2 Display resolution: 0.005 mV
- ±2 V: Measurable range: −2.2000 to +2.2000 V Measurement accuracy: ±0.05% of rdg ±0.4 mV *2 Display resolution: 0.1 mV
- ±20 V: Measurable range: −22.000 to +22.000 V Measurement accuracy: ±0.05% of rdg ±4 mV *2 Display resolution: 1 mV
- ±20 mA: Measurable range: −22.000 to +22.000 mA Measurement accuracy: ±0.08% of rdg ±0.004 mA *2 Display resolution: 0.001 mA
- ±200 mV: Measurable range: −220.00 to +220.00 mV Measurement accuracy: ±0.05% of rdg ±0.04 mV *2 Display resolution: 0.01 mV
- ±5 V: Measurable range: −5.5000 to +5.5000 V Measurement accuracy: ±0.05% of rdg ±0.8 mV *2 Display resolution: 0.2 mV
- ±500 mV: Measurable range: −550.00 to +550.00 mV Measurement accuracy: ±0.05% of rdg ±0.08 mV *2 Display resolution: 0.02 mV
Condition and supply
- New surplus, never used
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number NR-XHA08T with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- NR-XHA08T
- Brand
- KEYENCE
- Part Number
- NR-XHA08T
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- ±1 V
- Measurable range: −1.1000 to +1.1000 V Measurement accuracy: ±0.05% of rdg ±0.2 mV *2 Display resolution: 0.05 mV
- ±2 V
- Measurable range: −2.2000 to +2.2000 V Measurement accuracy: ±0.05% of rdg ±0.4 mV *2 Display resolution: 0.1 mV
- ±5 V
- Measurable range: −5.5000 to +5.5000 V Measurement accuracy: ±0.05% of rdg ±0.8 mV *2 Display resolution: 0.2 mV
- ±10 V
- Measurable range: −11.000 to +11.000 V Measurement accuracy: ±0.05% of rdg ±2 mV *2 Display resolution: 0.5 mV
- ±20 V
- Measurable range: −22.000 to +22.000 V Measurement accuracy: ±0.05% of rdg ±4 mV *2 Display resolution: 1 mV
- ±20 mA
- Measurable range: −22.000 to +22.000 mA Measurement accuracy: ±0.08% of rdg ±0.004 mA *2 Display resolution: 0.001 mA
- ±100 mV
- Measurable range: −110.000 to +110.000 mV Measurement accuracy: ±0.05% of rdg ±0.02 mV *2 Display resolution: 0.005 mV
- ±200 mV
- Measurable range: −220.00 to +220.00 mV Measurement accuracy: ±0.05% of rdg ±0.04 mV *2 Display resolution: 0.01 mV
- ±500 mV
- Measurable range: −550.00 to +550.00 mV Measurement accuracy: ±0.05% of rdg ±0.08 mV *2 Display resolution: 0.02 mV
- Averaging
- Switchable between ON/OFF, Averaging rate: 2 to 128 (moving average)
- Packaging
- New surplus, never used
- Input type
- Voltage input: ±60 V, ±20 V, ±10 V, ±5 V, ±2 V, ±1 V, ±500 mV, ±200 mV, ±100 mV Current input: ±20 mA
- Input method
- Insulated single-end input, channels insulated from each other, input channels insulated from the case and other units (system)
- Power supply
- Supplied from NR-X100W master unit
- Warm up time
- 30 minutes or more
- Buffer memory
- 16M data *3
- Current input
- Approx. 100 Ω
- A/D resolution
- 24 bits
- Shock resistance
- 1000 m/s 2 3280.8 ft/s 2
- Measurement cycle
- Maximum sampling cycle: 100 μs (10 kHz) to 60 s
- Power consumption
- 5.8 W or less
- Remote connection
- Dedicated environment-resistant remote unit input port × 1 (Remote IN), Output port × 1 (Remote OUT) Connection to NR-X100W master data collection unit or other NR-XR01 remote units using environment-resistant unit cable Connectable to multiple environment-resistant measurement units *4
- Withstand voltage
- Between measurement input terminal and case/other units (system): 1000 VAC (50 Hz / 60 Hz) for 1 minute Between measurement input terminals: 1000 VAC (50 Hz / 60 Hz) for 1 minute
- Input connector type
- Dedicated 3-pin connector
- Input frequency band
- 2 kHz (−3 dB or more)
- Maximum input rating
- Voltage input: ±60 V, Current input: ±30 mA
- Residual noise level
- 0.005% of F.S. (typ.) when A/D integration time is set to 20 ms (50 Hz) / 16.7 ms (60 Hz) 0.05% of F.S. (typ.) when A/D integration time is set to 208 μs (4.8 kHz) *2
- Vibration resistance
- 100 m/s 2 328.1 ft/s 2
- A/D converting system
- Delta-sigma method
- Number of input channels
- 8 *1
- Measurement range / ±60 V
- Measurable range: −60.000 to +60.000 V Measurement accuracy: ±0.05% of rdg ±8 mV *2 Display resolution: 2 mV
- Operating ambient humidity
- Max. 100% RH *7
- Surrounding air temperature
- −40 to +85°C -40°F to +185°F *6
- Common mode noise reduction ratio
- 105 dB or more (up to 60 Hz DC) (typ.) *2
- A/D integration time (noise filter)
- AUTO (Automatic configuration according to sampling cycle), 25 μs (40 kHz), 208 μs (4.8 kHz), 2.5 ms (400 Hz), 16.7 ms (60 Hz), 20 ms (50 Hz), 100 ms (10 Hz)
- Voltage input ±1 V range or higher
- 10 MΩ ±2%
- Maximum allowable input ground voltage
- 120 VAC and 170 Vpeak, or 120 VDC (when using NR-XHA08T protective grounding) The following applies when not using NR-XHA08T protective grounding. Dry locations: 30 VAC and 42.4 Vpeak, or 60 VDC Wet locations: 16 VAC and 22.6 Vpeak, or 35 VDC
- Input impedance / Voltage input ±2 V range or higher
- 1 MΩ ±2%
- Synchronization accuracy between remote connection units
- ±1 μs *5
Compatibility Information
Match NR-XHA08T against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing NR-XHA08T.
Maintenance Tips
Store NR-XHA08T dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. NR-XHA08T is in stock and ships within 1-2 business days, with a tracking number for every shipment.
NR-XHA08T is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match NR-XHA08T against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114