+86 13348028050
NR-X100W KEYENCE NR-X100W - Front View | Vcocnc FANUC Parts

KEYENCE NR-X100W

Product information

$3,587.92 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: NR-X100W

Alternate: NRX100W

Brand
KEYENCE
Part No.
NR-X100W
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE NR-X100W Product overview The KEYENCE NR-X100W is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Continuous acquisition speed / Master data collection unit group: Max. 100 kHz for all acquisition channels *6 - Control input / Common specifications: • Input type: Bidirectional voltage input • Maximum rating: 30 VDC, Minimum ON voltage: 10 VDC, Maximum OFF current: 0.2 mA • Insulation between input and system bus (500 VDC/1 minute) - Control output / Common specifications: • Output format: Photo MOS relay output • Maximum rating: 36 VDC, Output current: 50 mA or less (9-point total: 300 mA or less) • Leak current at OFF: 0.1 mA or less, Residual voltage when ON: 1 V or less • Insulation between output and system bus (500 VDC/1 minute) - Display/operation: Operation via NR-XCP30 control panel, or via WAVE LOGGER X with PC connection - Environmental resistance / Ambient temperature: 0 to +40°C 32°F to 104°F - Ethernet: RJ45 connector, 100Base-TX (AUTO MDI/MDIX supported) *3 - Expansion memory: SD card (SD/SDHC) *2 - Expansion remote unit connection: Dedicated remote connection connector × 2 (Remote OUT A port, B port) Unit expansion possible by connecting up to eight NR-XR01 remote units (connected by remote unit cable) - Individual specifications: • External trigger input (TRG IN): Edge input • Acquisition start/stop input (START IN): Level input (only enabled in external control mode) • Auto-balance input (BAL): Edge input (only enabled in external control mode) • Program selection input 0 to 3 (PROG IN0 to 3): Level input (only enabled in external control mode) - Input specifications: • For non-voltage input: ON voltage 1.0 V or lower (short circuit current: 1 mA typ.), OFF current 0.1 mA or lower • For voltage input: ON voltage (Lo) 1.0 V or lower, OFF voltage (Hi) 2.4 V or more, Max. input voltage: 6 V - Main unit buffer memory capacity: 50M data *1 - Network function: FTP client function, FTP server function, SNTP client function - Number of connectable measurement units / Master data collection unit group: Max. 8 units *4 - PC interface / USB: USB mini-B connector, USB 2.0 High-speed–compliant, Simultaneous USB connection from one PC to up to four units (switchable by ID switch) - Power supply: • NR-XU1 AC adapter, or 9 to 36 VDC (including ripple) / Max. 72 W (when connected to DC terminal block - Power supply / Power consumption: 8.4 W or less (excluding connected units) - Relative humidity: 10 to 85% RH (no condensation) - Synchronous trigger input (SYNC input) / Performance specifications: • Use as external trigger input (normal mode) or synchronous acquisition input (logging mode) • Non-voltage (contact/non-contact)/voltage input, Falling edge input • Not insulated from system bus - Time axis accuracy: ±50 ppm (23°C ±3°C 73.4°F ±5.4°F ) - Total with remote units connected: Max. 72 units *5 - Weight: Approx. 490 g 17.30 oz (including approx. 10 g 0.35 oz for the OP-88512 (NR-X100W I/O terminal block)) - Wireless LAN: Connection via NR-XW1 wireless LAN unit, IEEE 802.11b/g/n *3 - at 24 V: 3.0 A or less - at 36 V: 2.0 A or less) • Battery operation possible when connected to the NR-XU15 Series battery power supply unit - at 9 V: 8.0 A or less Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number NR-X100W with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
NR-X100W
Brand
KEYENCE
Part Number
NR-X100W
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Weight
Approx. 490 g 17.30 oz (including approx. 10 g 0.35 oz for the OP-88512 (NR-X100W I/O terminal block))
at 9 V
8.0 A or less
at 24 V
3.0 A or less
at 36 V
2.0 A or less) • Battery operation possible when connected to the NR-XU15 Series battery power supply unit
Ethernet
RJ45 connector, 100Base-TX (AUTO MDI/MDIX supported) *3
Packaging
New surplus, never used
Power supply
• NR-XU1 AC adapter, or 9 to 36 VDC (including ripple) / Max. 72 W (when connected to DC terminal block
Wireless LAN
Connection via NR-XW1 wireless LAN unit, IEEE 802.11b/g/n *3
Expansion memory
SD card (SD/SDHC) *2
Network function
FTP client function, FTP server function, SNTP client function
Display/operation
Operation via NR-XCP30 control panel, or via WAVE LOGGER X with PC connection
Relative humidity
10 to 85% RH (no condensation)
PC interface / USB
USB mini-B connector, USB 2.0 High-speed–compliant, Simultaneous USB connection from one PC to up to four units (switchable by ID switch)
Time axis accuracy
±50 ppm (23°C ±3°C 73.4°F ±5.4°F )
Input specifications
• For non-voltage input: ON voltage 1.0 V or lower (short circuit current: 1 mA typ.), OFF current 0.1 mA or lower • For voltage input: ON voltage (Lo) 1.0 V or lower, OFF voltage (Hi) 2.4 V or more, Max. input voltage: 6 V
Individual specifications
• External trigger input (TRG IN): Edge input • Acquisition start/stop input (START IN): Level input (only enabled in external control mode) • Auto-balance input (BAL): Edge input (only enabled in external control mode) • Program selection input 0 to 3 (PROG IN0 to 3): Level input (only enabled in external control mode)
Expansion remote unit connection
Dedicated remote connection connector × 2 (Remote OUT A port, B port) Unit expansion possible by connecting up to eight NR-XR01 remote units (connected by remote unit cable)
Main unit buffer memory capacity
50M data *1
Power supply / Power consumption
8.4 W or less (excluding connected units)
Total with remote units connected
Max. 72 units *5
Control input / Common specifications
• Input type: Bidirectional voltage input • Maximum rating: 30 VDC, Minimum ON voltage: 10 VDC, Maximum OFF current: 0.2 mA • Insulation between input and system bus (500 VDC/1 minute)
Control output / Common specifications
• Output format: Photo MOS relay output • Maximum rating: 36 VDC, Output current: 50 mA or less (9-point total: 300 mA or less) • Leak current at OFF: 0.1 mA or less, Residual voltage when ON: 1 V or less • Insulation between output and system bus (500 VDC/1 minute)
Environmental resistance / Ambient temperature
0 to +40°C 32°F to 104°F
Continuous acquisition speed / Master data collection unit group
Max. 100 kHz for all acquisition channels *6
Synchronous trigger input (SYNC input) / Performance specifications
• Use as external trigger input (normal mode) or synchronous acquisition input (logging mode) • Non-voltage (contact/non-contact)/voltage input, Falling edge input • Not insulated from system bus
Number of connectable measurement units / Master data collection unit group
Max. 8 units *4

Compatibility Information

Match NR-X100W against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing NR-X100W.

Maintenance Tips

Store NR-X100W dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114