Product Description
KEYENCE NR-TH08
Product overview
The KEYENCE NR-TH08 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- A/D converting system: Delta-sigma method
- A/D integration time: 2 ms, 16.7 ms, 20 ms
- A/D resolution: 24 bit
- B: Measurable range: 400 to 600°C 752°F to 1112°F , 600 to 1820°C 1112°F to 3308°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±1.7°C ±3.1°F , ±0.05% of rdg ±1.0°C ±1.8°F Display resolution: 0.05°C 0.09°F *3
- C: Measurable range: 1500 to 2315°C 2732°F to 4199°F , 0 to 1500°C 32°F to 2732°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±1.1°C ±2.0°F , ±0.05% of rdg ±0.8°C ±1.4°F Display resolution: 0.05°C 0.09°F *3
- E: Measurable range: −100 to +1000°C -148°F to +1832°F , −200 to −100°C -328°F to -148°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.6°C ±1.1°F , ±0.05% of rdg ±0.8°C ±1.4°F Display resolution: 0.05°C 0.09°F *3
- Input method: Floating unbalanced input, channels insulated from each other, CH inputs insulated from other units (PC), channels not insulated from each other for resistance thermometers
- Input type: Voltage: ±50 V, ±10 V, ±5 V, ±1 V, ±0.5 V, ±0.1 V
- J: Measurable range: −100 to +1200°C -148°F to +2192°F , −200 to −100°C -328°F to -148°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.6°C ±1.1°F , ±0.05% of rdg ±0.8°C ±1.4°F Display resolution: 0.05°C 0.09°F *3
- JPt100: Measurable range: −200 to +510°C -328°F to +950°F Me
- K: Measurable range: −100 to +1372°C -148°F to +2501.6°F , −200 to −100°C -328°F to -148°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.6°C ±1.1°F , ±0.05% of rdg ±0.9°C ±1.6°F Display resolution: 0.05°C 0.09°F *3
- Measurement cycle: Fastest sampling cycle: 100 ms (A/D integration time: 2 ms) to 1 h
- Measurement range / ±50 V: Measurable range: −55.00 to +55.00 V Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digits Display resolution: 10 mV
- N: Measurable range: 0 to 1300°C 32°F to 2372°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.6°C ±1.1°F Display resolution: 0.05°C 0.09°F *3
- Number of channels: Input: 8 *2
- Pt100: Measurable range: −200 to +660°C -328°F to +1220°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.1% of rdg ±0.3°C ±0.5°F Display resolution: 0.02°C 0.04°F *4
- R: Measurable range: 300 to 1768°C 572°F to 3214.4°F , 0 to 300°C 32°F to 572°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.8°C ±1.4°F , ±0.05% of rdg ±1.6°C ±2.9°F Display resolution: 0.05°C 0.09°F *3
- Resistance thermometer: Pt100, JPt100 3-line type
- S: Measurable range: 300 to 1768°C 572°F to 3214.4°F , 0 to 300°C 32°F to 572°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.9°C ±1.6°F , ±0.05% of rdg ±1.6°C ±2.9°F Display resolution: 0.05°C 0.09°F *3
- Specified current: 1 mA
- T: Measurable range: −100 to +400°C -148°F to +752°F , −200 to −100°C -328°F to -148°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.5°C ±0.9°F , ±0.05% of rdg ±0.8°C ±1.4°F Display resolution: 0.01°C 0.02°F *3
- Type: High-accuracy temperature/voltage measurement unit
- ±1 V: Measurable range: −1.1000 to +1.1000 V Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digits Display resolution: 0.1 mV
- ±10 V: Measurable range: −11.000 to +11.000 V Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digits Display resolution: 1 mV
- ±100 mV: Measurable range: −110.00 to +110.00 mV Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digits Display resolution: 0.01 mV
- ±5 V: Measurable range: −5.500 to +5.500 V Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digits Display resolution: 1 mV
- ±500 mV: Measurable range: −550.0 to +550.0 mV Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digits Display resolution: 0.1 mV
Condition and supply
- New surplus, factory sealed original packaging
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number NR-TH08 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- NR-TH08
- Brand
- KEYENCE
- Part Number
- NR-TH08
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- B
- Measurable range: 400 to 600°C 752°F to 1112°F , 600 to 1820°C 1112°F to 3308°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±1.7°C ±3.1°F , ±0.05% of rdg ±1.0°C ±1.8°F Display resolution: 0.05°C 0.09°F *3
- C
- Measurable range: 1500 to 2315°C 2732°F to 4199°F , 0 to 1500°C 32°F to 2732°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±1.1°C ±2.0°F , ±0.05% of rdg ±0.8°C ±1.4°F Display resolution: 0.05°C 0.09°F *3
- E
- Measurable range: −100 to +1000°C -148°F to +1832°F , −200 to −100°C -328°F to -148°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.6°C ±1.1°F , ±0.05% of rdg ±0.8°C ±1.4°F Display resolution: 0.05°C 0.09°F *3
- J
- Measurable range: −100 to +1200°C -148°F to +2192°F , −200 to −100°C -328°F to -148°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.6°C ±1.1°F , ±0.05% of rdg ±0.8°C ±1.4°F Display resolution: 0.05°C 0.09°F *3
- K
- Measurable range: −100 to +1372°C -148°F to +2501.6°F , −200 to −100°C -328°F to -148°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.6°C ±1.1°F , ±0.05% of rdg ±0.9°C ±1.6°F Display resolution: 0.05°C 0.09°F *3
- N
- Measurable range: 0 to 1300°C 32°F to 2372°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.6°C ±1.1°F Display resolution: 0.05°C 0.09°F *3
- R
- Measurable range: 300 to 1768°C 572°F to 3214.4°F , 0 to 300°C 32°F to 572°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.8°C ±1.4°F , ±0.05% of rdg ±1.6°C ±2.9°F Display resolution: 0.05°C 0.09°F *3
- S
- Measurable range: 300 to 1768°C 572°F to 3214.4°F , 0 to 300°C 32°F to 572°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.9°C ±1.6°F , ±0.05% of rdg ±1.6°C ±2.9°F Display resolution: 0.05°C 0.09°F *3
- T
- Measurable range: −100 to +400°C -148°F to +752°F , −200 to −100°C -328°F to -148°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.5°C ±0.9°F , ±0.05% of rdg ±0.8°C ±1.4°F Display resolution: 0.01°C 0.02°F *3
- Type
- High-accuracy temperature/voltage measurement unit
- Pt100
- Measurable range: −200 to +660°C -328°F to +1220°F Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.1% of rdg ±0.3°C ±0.5°F Display resolution: 0.02°C 0.04°F *4
- ±1 V
- Measurable range: −1.1000 to +1.1000 V Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digits Display resolution: 0.1 mV
- ±5 V
- Measurable range: −5.500 to +5.500 V Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digits Display resolution: 1 mV
- JPt100
- Measurable range: −200 to +510°C -328°F to +950°F Me
- ±10 V
- Measurable range: −11.000 to +11.000 V Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digits Display resolution: 1 mV
- ±100 mV
- Measurable range: −110.00 to +110.00 mV Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digits Display resolution: 0.01 mV
- ±500 mV
- Measurable range: −550.0 to +550.0 mV Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digits Display resolution: 0.1 mV
- Packaging
- New surplus, factory sealed original packaging
- Input type
- Voltage: ±50 V, ±10 V, ±5 V, ±1 V, ±0.5 V, ±0.1 V
- Input method
- Floating unbalanced input, channels insulated from each other, CH inputs insulated from other units (PC), channels not insulated from each other for resistance thermometers
- A/D resolution
- 24 bit
- Measurement cycle
- Fastest sampling cycle: 100 ms (A/D integration time: 2 ms) to 1 h
- Specified current
- 1 mA
- Number of channels
- Input: 8 *2
- A/D integration time
- 2 ms, 16.7 ms, 20 ms
- A/D converting system
- Delta-sigma method
- Resistance thermometer
- Pt100, JPt100 3-line type
- Measurement range / ±50 V
- Measurable range: −55.00 to +55.00 V Measurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digits Display resolution: 10 mV
Compatibility Information
Match NR-TH08 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing NR-TH08.
Maintenance Tips
Store NR-TH08 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. NR-TH08 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
NR-TH08 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match NR-TH08 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114