+86 13348028050
NR-ST04 KEYENCE NR-ST04 - Front View | Vcocnc FANUC Parts

KEYENCE NR-ST04

Product information

$1,324.69 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: NR-ST04

Alternate: NRST04

Brand
KEYENCE
Part No.
NR-ST04
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE NR-ST04 Product overview The KEYENCE NR-ST04 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - A/D converting system: Successive approximation, simultaneous sampling of all channels - A/D resolution: 16 bit - Applicable gauge resistance: Quarter bridge / half bridge system: 120 Ω (A 350 Ω strain gauge requires an external bridge box.) - Applied voltage: 2 VDC (±0.4%) - Attenuation characteristics: 5th order Bessel filter, −30 dB/oct - Balance adjustment / System: Electronic balancing (auto-balancing) - Balance adjustment accuracy: ±0.1% of F.S. (with low-pass filter of 8 Hz and 50 Hz sampling averaged 20 times) - Balance adjustment range: ±29000 μST (during strain input), ±29 mV (during voltage input) - Buffer memory: 4M data *4 - Chronological changes: ±1.5 μST/8 h, ±3 μV/8 h *5 - Common mode noise reduction ratio: 80 dB or more (60 Hz DC max.) - Display resolution: ±50 mV: 10 μV ±20 mV: 1 μV ±10 mV: 1 μV ±5 mV: 1 μV ±2 mV: 0.1 μV ±20000 μST: 1 μST ±10000 μST: 0.5 μST ±5000 μS: 0.25 μST ±2000 μST: 0.1 μST ±1000 μST: 0.05 μST - Environmental resistance / Ambient temperature: 0 to +40°C 32°F to 104°F - Full bridge system: 120 Ω to 1 kΩ - Gain stability / Temperature characteristics: ±0.05% of F.S./°C *5 - Gauge ratio: 2.0 (fixed) - Input frequency band: 5 kHz DC max. (−3 dB) - Input impedance: 1 MΩ or more - Input method: Balanced differential input, channels not insulated from each other, input channels insulated from other units (PC) - Input type / Voltage input: ±2 mV, ±5 mV, ±10 mV, ±20 mV, ±50 mV - Low pass filter / Cutoff frequency: Auto, 5 kHz, 3.5 kHz (3 kHz), 2 kHz (1.5 kHz), 1 kHz (750 Hz), 500 Hz (370 Hz), 250 Hz (200 Hz), 120 Hz (100 Hz), 60 Hz (50 Hz), 30 Hz (25 Hz), 15 Hz (12 Hz), 8 Hz (6 Hz), 4 Hz (3 Hz) - Maximum input rating: ±1.0 V - Measurable range: ±50 mV: −55.00 to +55.00 mV ±20 mV: −22.000 to +22.000 mV ±10 mV: −11.000 to +11.000 mV ±5 mV: −5.500 to +5.500 mV ±2 mV: −2.2000 to +2.2000 mV ±20000 μST: −22000 to +22000 μST ±10000 μST: −11000.0 to +11000.0 μST ±5000 μS: −5500.00 to +5500.00 μST ±2000 μST: −2200.0 to +2200.0 μST ±1000 μST: −1100.00 to +1100.00 μST - Measurement accuracy / Gain accuracy: ±0.2% of F.S. (with low-pass filter of 8 Hz and 50 Hz sampling averaged 20 times) - Measurement cycle: Maximum sampling cycle: 20 μs (50 kHz) to 60 s - Number of channels: 4 ch *3 - Rating / Power consumption: 3.0 W or less - Relative humidity: 10 to 85% RH (no condensation) - Strain input: ±1000 μST, ±2000 μST, ±5000 μST, ±10000 μST, ±20000 μST - Type: Strain measurement unit - Warm up time: 30 minutes or more - Weight: Approx. 230 g 8.12 oz (including two OP-51584: NR-ST04 10-pole terminal blocks) - Withstand voltage / Input to system bus/earth: 1500 VAC (50/60 Hz) for 1 minute - Zero-point stability / Temperature characteristics: ±2 μST/°C, ±2 μV/°C *5 Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number NR-ST04 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
NR-ST04
Brand
KEYENCE
Part Number
NR-ST04
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
Strain measurement unit
Weight
Approx. 230 g 8.12 oz (including two OP-51584: NR-ST04 10-pole terminal blocks)
Packaging
New surplus, factory sealed original packaging
Gauge ratio
2.0 (fixed)
Input method
Balanced differential input, channels not insulated from each other, input channels insulated from other units (PC)
Strain input
±1000 μST, ±2000 μST, ±5000 μST, ±10000 μST, ±20000 μST
Warm up time
30 minutes or more
Buffer memory
4M data *4
A/D resolution
16 bit
Applied voltage
2 VDC (±0.4%)
Input impedance
1 MΩ or more
Measurable range
±50 mV: −55.00 to +55.00 mV ±20 mV: −22.000 to +22.000 mV ±10 mV: −11.000 to +11.000 mV ±5 mV: −5.500 to +5.500 mV ±2 mV: −2.2000 to +2.2000 mV ±20000 μST: −22000 to +22000 μST ±10000 μST: −11000.0 to +11000.0 μST ±5000 μS: −5500.00 to +5500.00 μST ±2000 μST: −2200.0 to +2200.0 μST ±1000 μST: −1100.00 to +1100.00 μST
Measurement cycle
Maximum sampling cycle: 20 μs (50 kHz) to 60 s
Relative humidity
10 to 85% RH (no condensation)
Display resolution
±50 mV: 10 μV ±20 mV: 1 μV ±10 mV: 1 μV ±5 mV: 1 μV ±2 mV: 0.1 μV ±20000 μST: 1 μST ±10000 μST: 0.5 μST ±5000 μS: 0.25 μST ±2000 μST: 0.1 μST ±1000 μST: 0.05 μST
Full bridge system
120 Ω to 1 kΩ
Number of channels
4 ch *3
Input frequency band
5 kHz DC max. (−3 dB)
Maximum input rating
±1.0 V
A/D converting system
Successive approximation, simultaneous sampling of all channels
Chronological changes
±1.5 μST/8 h, ±3 μV/8 h *5
Balance adjustment range
±29000 μST (during strain input), ±29 mV (during voltage input)
Input type / Voltage input
±2 mV, ±5 mV, ±10 mV, ±20 mV, ±50 mV
Rating / Power consumption
3.0 W or less
Applicable gauge resistance
Quarter bridge / half bridge system: 120 Ω (A 350 Ω strain gauge requires an external bridge box.)
Attenuation characteristics
5th order Bessel filter, −30 dB/oct
Balance adjustment / System
Electronic balancing (auto-balancing)
Balance adjustment accuracy
±0.1% of F.S. (with low-pass filter of 8 Hz and 50 Hz sampling averaged 20 times)
Common mode noise reduction ratio
80 dB or more (60 Hz DC max.)
Low pass filter / Cutoff frequency
Auto, 5 kHz, 3.5 kHz (3 kHz), 2 kHz (1.5 kHz), 1 kHz (750 Hz), 500 Hz (370 Hz), 250 Hz (200 Hz), 120 Hz (100 Hz), 60 Hz (50 Hz), 30 Hz (25 Hz), 15 Hz (12 Hz), 8 Hz (6 Hz), 4 Hz (3 Hz)
Measurement accuracy / Gain accuracy
±0.2% of F.S. (with low-pass filter of 8 Hz and 50 Hz sampling averaged 20 times)
Gain stability / Temperature characteristics
±0.05% of F.S./°C *5
Withstand voltage / Input to system bus/earth
1500 VAC (50/60 Hz) for 1 minute
Environmental resistance / Ambient temperature
0 to +40°C 32°F to 104°F
Zero-point stability / Temperature characteristics
±2 μST/°C, ±2 μV/°C *5

Compatibility Information

Match NR-ST04 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing NR-ST04.

Maintenance Tips

Store NR-ST04 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114