KEYENCE NR-ST04
Product overview
The KEYENCE NR-ST04 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- A/D converting system: Successive approximation, simultaneous sampling of all channels
- A/D resolution: 16 bit
- Applicable gauge resistance: Quarter bridge / half bridge system: 120 Ω (A 350 Ω strain gauge requires an external bridge box.)
- Applied voltage: 2 VDC (±0.4%)
- Attenuation characteristics: 5th order Bessel filter, −30 dB/oct
- Balance adjustment / System: Electronic balancing (auto-balancing)
- Balance adjustment accuracy: ±0.1% of F.S. (with low-pass filter of 8 Hz and 50 Hz sampling averaged 20 times)
- Balance adjustment range: ±29000 μST (during strain input), ±29 mV (during voltage input)
- Buffer memory: 4M data *4
- Chronological changes: ±1.5 μST/8 h, ±3 μV/8 h *5
- Common mode noise reduction ratio: 80 dB or more (60 Hz DC max.)
- Display resolution: ±50 mV: 10 μV ±20 mV: 1 μV ±10 mV: 1 μV ±5 mV: 1 μV ±2 mV: 0.1 μV ±20000 μST: 1 μST ±10000 μST: 0.5 μST ±5000 μS: 0.25 μST ±2000 μST: 0.1 μST ±1000 μST: 0.05 μST
- Environmental resistance / Ambient temperature: 0 to +40°C 32°F to 104°F
- Full bridge system: 120 Ω to 1 kΩ
- Gain stability / Temperature characteristics: ±0.05% of F.S./°C *5
- Gauge ratio: 2.0 (fixed)
- Input frequency band: 5 kHz DC max. (−3 dB)
- Input impedance: 1 MΩ or more
- Input method: Balanced differential input, channels not insulated from each other, input channels insulated from other units (PC)
- Input type / Voltage input: ±2 mV, ±5 mV, ±10 mV, ±20 mV, ±50 mV
- Low pass filter / Cutoff frequency: Auto, 5 kHz, 3.5 kHz (3 kHz), 2 kHz (1.5 kHz), 1 kHz (750 Hz), 500 Hz (370 Hz), 250 Hz (200 Hz), 120 Hz (100 Hz), 60 Hz (50 Hz), 30 Hz (25 Hz), 15 Hz (12 Hz), 8 Hz (6 Hz), 4 Hz (3 Hz)
- Maximum input rating: ±1.0 V
- Measurable range: ±50 mV: −55.00 to +55.00 mV ±20 mV: −22.000 to +22.000 mV ±10 mV: −11.000 to +11.000 mV ±5 mV: −5.500 to +5.500 mV ±2 mV: −2.2000 to +2.2000 mV ±20000 μST: −22000 to +22000 μST ±10000 μST: −11000.0 to +11000.0 μST ±5000 μS: −5500.00 to +5500.00 μST ±2000 μST: −2200.0 to +2200.0 μST ±1000 μST: −1100.00 to +1100.00 μST
- Measurement accuracy / Gain accuracy: ±0.2% of F.S. (with low-pass filter of 8 Hz and 50 Hz sampling averaged 20 times)
- Measurement cycle: Maximum sampling cycle: 20 μs (50 kHz) to 60 s
- Number of channels: 4 ch *3
- Rating / Power consumption: 3.0 W or less
- Relative humidity: 10 to 85% RH (no condensation)
- Strain input: ±1000 μST, ±2000 μST, ±5000 μST, ±10000 μST, ±20000 μST
- Type: Strain measurement unit
- Warm up time: 30 minutes or more
- Weight: Approx. 230 g 8.12 oz (including two OP-51584: NR-ST04 10-pole terminal blocks)
- Withstand voltage / Input to system bus/earth: 1500 VAC (50/60 Hz) for 1 minute
- Zero-point stability / Temperature characteristics: ±2 μST/°C, ±2 μV/°C *5
Condition and supply
- New surplus, factory sealed original packaging
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number NR-ST04 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- NR-ST04
- Brand
- KEYENCE
- Part Number
- NR-ST04
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Type
- Strain measurement unit
- Weight
- Approx. 230 g 8.12 oz (including two OP-51584: NR-ST04 10-pole terminal blocks)
- Packaging
- New surplus, factory sealed original packaging
- Gauge ratio
- 2.0 (fixed)
- Input method
- Balanced differential input, channels not insulated from each other, input channels insulated from other units (PC)
- Strain input
- ±1000 μST, ±2000 μST, ±5000 μST, ±10000 μST, ±20000 μST
- Warm up time
- 30 minutes or more
- Buffer memory
- 4M data *4
- A/D resolution
- 16 bit
- Applied voltage
- 2 VDC (±0.4%)
- Input impedance
- 1 MΩ or more
- Measurable range
- ±50 mV: −55.00 to +55.00 mV ±20 mV: −22.000 to +22.000 mV ±10 mV: −11.000 to +11.000 mV ±5 mV: −5.500 to +5.500 mV ±2 mV: −2.2000 to +2.2000 mV ±20000 μST: −22000 to +22000 μST ±10000 μST: −11000.0 to +11000.0 μST ±5000 μS: −5500.00 to +5500.00 μST ±2000 μST: −2200.0 to +2200.0 μST ±1000 μST: −1100.00 to +1100.00 μST
- Measurement cycle
- Maximum sampling cycle: 20 μs (50 kHz) to 60 s
- Relative humidity
- 10 to 85% RH (no condensation)
- Display resolution
- ±50 mV: 10 μV ±20 mV: 1 μV ±10 mV: 1 μV ±5 mV: 1 μV ±2 mV: 0.1 μV ±20000 μST: 1 μST ±10000 μST: 0.5 μST ±5000 μS: 0.25 μST ±2000 μST: 0.1 μST ±1000 μST: 0.05 μST
- Full bridge system
- 120 Ω to 1 kΩ
- Number of channels
- 4 ch *3
- Input frequency band
- 5 kHz DC max. (−3 dB)
- Maximum input rating
- ±1.0 V
- A/D converting system
- Successive approximation, simultaneous sampling of all channels
- Chronological changes
- ±1.5 μST/8 h, ±3 μV/8 h *5
- Balance adjustment range
- ±29000 μST (during strain input), ±29 mV (during voltage input)
- Input type / Voltage input
- ±2 mV, ±5 mV, ±10 mV, ±20 mV, ±50 mV
- Rating / Power consumption
- 3.0 W or less
- Applicable gauge resistance
- Quarter bridge / half bridge system: 120 Ω (A 350 Ω strain gauge requires an external bridge box.)
- Attenuation characteristics
- 5th order Bessel filter, −30 dB/oct
- Balance adjustment / System
- Electronic balancing (auto-balancing)
- Balance adjustment accuracy
- ±0.1% of F.S. (with low-pass filter of 8 Hz and 50 Hz sampling averaged 20 times)
- Common mode noise reduction ratio
- 80 dB or more (60 Hz DC max.)
- Low pass filter / Cutoff frequency
- Auto, 5 kHz, 3.5 kHz (3 kHz), 2 kHz (1.5 kHz), 1 kHz (750 Hz), 500 Hz (370 Hz), 250 Hz (200 Hz), 120 Hz (100 Hz), 60 Hz (50 Hz), 30 Hz (25 Hz), 15 Hz (12 Hz), 8 Hz (6 Hz), 4 Hz (3 Hz)
- Measurement accuracy / Gain accuracy
- ±0.2% of F.S. (with low-pass filter of 8 Hz and 50 Hz sampling averaged 20 times)
- Gain stability / Temperature characteristics
- ±0.05% of F.S./°C *5
- Withstand voltage / Input to system bus/earth
- 1500 VAC (50/60 Hz) for 1 minute
- Environmental resistance / Ambient temperature
- 0 to +40°C 32°F to 104°F
- Zero-point stability / Temperature characteristics
- ±2 μST/°C, ±2 μV/°C *5
Compatibility Information
Match NR-ST04 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing NR-ST04.
Maintenance Tips
Store NR-ST04 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. NR-ST04 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
NR-ST04 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match NR-ST04 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114