KEYENCE NR-PM01
Product information
SKU: NR-PM01
Alternate: NRPM01
Brand
KEYENCE
Part No.
NR-PM01
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
KEYENCE NR-PM01
Product overview
The KEYENCE NR-PM01 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- 1-phase 3-wire: 100–240 V AC (L-N), 200–480 V AC (L-L)
- 3-phase 3-wire: With dedicated NR-CT250/CT600 CT: 173–480 V AC (L-L) With dedicated NR-CT050/CT100 CT: 173–240 V AC (L-L)
- 3-phase 4-wire: With dedicated NR-CT250/CT600 CT: 100–277 V AC (L-N), 173–480 V AC (L-L) With dedicated NR-CT050/CT100 CT: 100–240 V AC (L-N), 173–415 V AC (L-L)
- Active energy (power factor of 1): ±1.0% of rdg (1% ≤ In ≤ 120%) *2
- Active energy/Reactive energy/Apparent energy (Instantaneous): Measurable range: -8942.400 to +8942.400 [kW/kvar/kVA] Display resolution: 0.001 [kW/kvar/kVA]
- Active energy/Reactive energy/Apparent energy (Integrated): Measurable range: 0.000 to 999999.999 [kWh/kvarh/kVah] Display resolution: 0.001 [kWh/kvarh/kVAh]
- Apparent energy: With dedicated NR-CT250/CT600 CT: ±1.0% of rdg (1% ≤ In ≤ 120%) *3 With dedicated NR-CT050/CT100 CT: ±1.0% of rdg (5% ≤ In ≤ 120%) *3 *2
- Current: Measurable range: Within primary side rated current Display resolution: 0.001 A
- Current consumption: 36 mA or less
- Effects of ambient temperature: ±0.03% of rdg/°C *4 *2
- Frequency: Measurable range: 0.0 to 90.0 Hz Display resolution: 0.1 Hz
- General specifications / Power voltage: —(Powered by NR-PMC10)
- Input voltage fluctuation range: −15% to +15% of rated input voltage
- Insulation resistance: 20 MΩ or more at 500 V DC • Between all terminals and case • Between voltage measurement terminal, all CT input terminals and expansion port
- Material: Polycarbonate
- Maximum allowable earth voltage: With dedicated NR-CT250/CT600 CT: 480 V AC With dedicated NR-CT050/CT100 CT: 240 V AC
- Measurement accuracy / Voltage: ±0.5% of rdg (within rated input voltage) *2
- Measurement range / Voltage: Measurable range: Within rated input voltage Display resolution: 0.1 V
- No. of measurement circuits: 1
- Operating ambient humidity: Max. 85% RH (no condensation)
- Operating ambient temperature: 0 to 55°C 32°F to 131°F (no freezing)
- Overcurrent withstand capability: 1.2 times the primary side rated current (can be continuous), 10 times the primary side rated current (1 sec or less)
- Performance Specifications / Measurement specifications: Phase wire system 1-phase 2-wire, 1-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire (switchable)
- Power factor (PF): Measurable range: -1.00–1.00 Display resolution: 0.01
- Power spectral density: 0.033 G 2 /Hz for X, Y and Z directions
- Primary side rated current (In): With dedicated NR-CT250 CT: 250 A With dedicated NR-CT600 CT: 600 A With dedicated NR-CT050 CT: 50 A With dedicated NR-CT100 CT: 100 A or general-purpose CT (secondary side rated input current 1 A) *1
- Rated input frequency: 50/60 Hz
- Rated input voltage (direct input) / 1-phase 2-wire: With dedicated NR-CT250/CT600 CT: 100–277 V AC (L-N) With dedicated NR-CT050/CT100 CT: 100–240 V AC (L-N)
- Reactive energy (reactive power factor of 1): ±2.0% of rdg (5% ≤ In ≤ 120%) *2
- Vibration: Frequency: 10 to 500 Hz
- Weight: Approx. 110 g 3.88 oz
- Withstand voltage: 2500 V AC/minute • Between all terminals and case • Between voltage measurement terminal and expansion port • Between CT input terminal and expansion port * With dedicated CT
Condition and supply
- Price on request: send an inquiry with the quantity you need
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number NR-PM01 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- NR-PM01
- Brand
- KEYENCE
- Part Number
- NR-PM01
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Weight
- Approx. 110 g 3.88 oz
- Current
- Measurable range: Within primary side rated current Display resolution: 0.001 A
- Material
- Polycarbonate
- Frequency
- Measurable range: 0.0 to 90.0 Hz Display resolution: 0.1 Hz
- Vibration
- Frequency: 10 to 500 Hz
- 1-phase 3-wire
- 100–240 V AC (L-N), 200–480 V AC (L-L)
- 3-phase 3-wire
- With dedicated NR-CT250/CT600 CT: 173–480 V AC (L-L) With dedicated NR-CT050/CT100 CT: 173–240 V AC (L-L)
- 3-phase 4-wire
- With dedicated NR-CT250/CT600 CT: 100–277 V AC (L-N), 173–480 V AC (L-L) With dedicated NR-CT050/CT100 CT: 100–240 V AC (L-N), 173–415 V AC (L-L)
- Apparent energy
- With dedicated NR-CT250/CT600 CT: ±1.0% of rdg (1% ≤ In ≤ 120%) *3 With dedicated NR-CT050/CT100 CT: ±1.0% of rdg (5% ≤ In ≤ 120%) *3 *2
- Power factor (PF)
- Measurable range: -1.00–1.00 Display resolution: 0.01
- Withstand voltage
- 2500 V AC/minute • Between all terminals and case • Between voltage measurement terminal and expansion port • Between CT input terminal and expansion port * With dedicated CT
- Current consumption
- 36 mA or less
- Insulation resistance
- 20 MΩ or more at 500 V DC • Between all terminals and case • Between voltage measurement terminal, all CT input terminals and expansion port
- Rated input frequency
- 50/60 Hz
- Power spectral density
- 0.033 G 2 /Hz for X, Y and Z directions
- Operating ambient humidity
- Max. 85% RH (no condensation)
- Measurement range / Voltage
- Measurable range: Within rated input voltage Display resolution: 0.1 V
- No. of measurement circuits
- 1
- Operating ambient temperature
- 0 to 55°C 32°F to 131°F (no freezing)
- Effects of ambient temperature
- ±0.03% of rdg/°C *4 *2
- Measurement accuracy / Voltage
- ±0.5% of rdg (within rated input voltage) *2
- Input voltage fluctuation range
- −15% to +15% of rated input voltage
- Maximum allowable earth voltage
- With dedicated NR-CT250/CT600 CT: 480 V AC With dedicated NR-CT050/CT100 CT: 240 V AC
- Primary side rated current (In)
- With dedicated NR-CT250 CT: 250 A With dedicated NR-CT600 CT: 600 A With dedicated NR-CT050 CT: 50 A With dedicated NR-CT100 CT: 100 A or general-purpose CT (secondary side rated input current 1 A) *1
- Overcurrent withstand capability
- 1.2 times the primary side rated current (can be continuous), 10 times the primary side rated current (1 sec or less)
- Active energy (power factor of 1)
- ±1.0% of rdg (1% ≤ In ≤ 120%) *2
- General specifications / Power voltage
- —(Powered by NR-PMC10)
- Reactive energy (reactive power factor of 1)
- ±2.0% of rdg (5% ≤ In ≤ 120%) *2
- Rated input voltage (direct input) / 1-phase 2-wire
- With dedicated NR-CT250/CT600 CT: 100–277 V AC (L-N) With dedicated NR-CT050/CT100 CT: 100–240 V AC (L-N)
- Performance Specifications / Measurement specifications
- Phase wire system 1-phase 2-wire, 1-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire (switchable)
- Active energy/Reactive energy/Apparent energy (Integrated)
- Measurable range: 0.000 to 999999.999 [kWh/kvarh/kVah] Display resolution: 0.001 [kWh/kvarh/kVAh]
- Active energy/Reactive energy/Apparent energy (Instantaneous)
- Measurable range: -8942.400 to +8942.400 [kW/kvar/kVA] Display resolution: 0.001 [kW/kvar/kVA]
Compatibility Information
Match NR-PM01 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing NR-PM01.
Maintenance Tips
Store NR-PM01 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. NR-PM01 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
NR-PM01 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match NR-PM01 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114