+86 13348028050
NR-HV04 KEYENCE NR-HV04 - Front View | Vcocnc FANUC Parts

KEYENCE NR-HV04

Product information

$1,735.82 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: NR-HV04

Alternate: NRHV04

Brand
KEYENCE
Part No.
NR-HV04
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE NR-HV04 Product overview The KEYENCE NR-HV04 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - 0.05% of F.S., LPF: PASS (typ.) - A/D converting system: Successive approximation, simultaneous sampling of all channels - A/D resolution: 14 bit - Ambient temperature: 0 to +40°C 32°F to 104°F - Buffer memory: 16M data *4 - Calculationfunction: CH1 to CH2, CH3 to CH4 (Single-channel usage not possible when using the calculation function) - Common mode noise reduction ratio: 80 dB or more (at max. 60 Hz DC) (typ.) - Connector format: Insulated BNC connector - Crest factor: 4 or less - Digital filter: Averaging rate: 1 to 128 (automatically selected) - Display resolution: ±1000 V: 50 mV ±500 V: 20 mV ±200 V: 10 mV ±100 V: 5 mV ±50 V: 2 mV ±20 V: 1 mV ±10 V: 0.5 mV ±5 V: 0.2 mV ±2 V: 0.1 mV - Environmental resistance / Insulation resistance: 500 VDC, 10 MΩ or more - Input coupling: AC/DC/AC-RMS/DC-RMS - Input frequency band: 250 kHz (−3 dB or more) - Input impedance: 1 MΩ ±1%, approx. 30 pF - Input method: Insulated single-end input, channels insulated from each other, input channels insulated from other units (PC) - Input type: ±1000 V, ±500 V, ±200 V, ±100 V, ±50 V, ±20 V, ±10 V, ±5 V, ±2 V - Low pass filter: PASS, 7 Hz, 500 Hz, 50 kHz (−12 dB/oct) - Maximum allowable voltage to ground: [When using OP-89263 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II) - Maximum input voltage: [When using OP-89263 1:1 voltage-resistant probe] 1000 V peak and 700 Vrms, or 700 VDC - Measurable range: ±1000 V: −1000.00 to +1000.00 V ±500 V: −550.00 to +550.00 V ±200 V: −220.00 to +220.00 V ±100 V: −110.000 to +110.000 V ±50 V: −55.000 to +55.000 V ±20 V: −22.000 to +22.000 V ±10 V: −11.0000 to +11.0000 V ±5 V: −5.5000 to +5.5000 V ±2 V: −2.2000 to +2.2000 V - Measurement accuracy: ±0.1% of F.S., LPF: 500 Hz, with digital filter ON - Measurement cycle: Maximum sampling cycle: 1 μs (1 MHz) to 60 s - Number of channels: 4 ch *2 - RMS measurement function / Accuracy: Sine wave: 20 Hz to 1 kHz, ±0.5% of F.S. - RMS measurement function / Number of channels: 4 ch - Rating / Power consumption: 3 W or less - Relative humidity: 10 to 85% RH (no condensation) - Residual noise level: 0.01% of F.S., LPF: 500 Hz (200 μs/S, digital filter: ON) (typ.) - Response time: 500 ms - Type: High-speed, high-voltage measurement unit - Warm up time: 30 minutes or more - Weight: Approx. 270 g 9.53 oz - Withstand voltage / Input to system bus/earth: 2200 VAC (50/60 Hz) for 1 minute - [Direct input] Measurement terminal, GND terminal: 42.4 Vpeak and 30 Vrms, or 60 VDC *3 - [When using OP-88998 10:1 voltage-resistant probe] Measurement terminal: 700 Vrms (CAT II), GND terminal: 300 Vrms (CAT II) Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number NR-HV04 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
NR-HV04
Brand
KEYENCE
Part Number
NR-HV04
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
High-speed, high-voltage measurement unit
Weight
Approx. 270 g 9.53 oz
Packaging
New surplus, never used
Input type
±1000 V, ±500 V, ±200 V, ±100 V, ±50 V, ±20 V, ±10 V, ±5 V, ±2 V
Crest factor
4 or less
Input method
Insulated single-end input, channels insulated from each other, input channels insulated from other units (PC)
Warm up time
30 minutes or more
Buffer memory
16M data *4
Response time
500 ms
A/D resolution
14 bit
Digital filter
Averaging rate: 1 to 128 (automatically selected)
Input coupling
AC/DC/AC-RMS/DC-RMS
Input impedance
1 MΩ ±1%, approx. 30 pF
Low pass filter
PASS, 7 Hz, 500 Hz, 50 kHz (−12 dB/oct)
Connector format
Insulated BNC connector
Measurable range
±1000 V: −1000.00 to +1000.00 V ±500 V: −550.00 to +550.00 V ±200 V: −220.00 to +220.00 V ±100 V: −110.000 to +110.000 V ±50 V: −55.000 to +55.000 V ±20 V: −22.000 to +22.000 V ±10 V: −11.0000 to +11.0000 V ±5 V: −5.5000 to +5.5000 V ±2 V: −2.2000 to +2.2000 V
Measurement cycle
Maximum sampling cycle: 1 μs (1 MHz) to 60 s
Relative humidity
10 to 85% RH (no condensation)
0.05% of F.S., LPF
PASS (typ.)
Display resolution
±1000 V: 50 mV ±500 V: 20 mV ±200 V: 10 mV ±100 V: 5 mV ±50 V: 2 mV ±20 V: 1 mV ±10 V: 0.5 mV ±5 V: 0.2 mV ±2 V: 0.1 mV
Number of channels
4 ch *2
Ambient temperature
0 to +40°C 32°F to 104°F
Calculationfunction
CH1 to CH2, CH3 to CH4 (Single-channel usage not possible when using the calculation function)
Input frequency band
250 kHz (−3 dB or more)
Measurement accuracy
±0.1% of F.S., LPF: 500 Hz, with digital filter ON
Residual noise level
0.01% of F.S., LPF: 500 Hz (200 μs/S, digital filter: ON) (typ.)
A/D converting system
Successive approximation, simultaneous sampling of all channels
Maximum input voltage
[When using OP-89263 1:1 voltage-resistant probe] 1000 V peak and 700 Vrms, or 700 VDC
Rating / Power consumption
3 W or less
Common mode noise reduction ratio
80 dB or more (at max. 60 Hz DC) (typ.)
Maximum allowable voltage to ground
[When using OP-89263 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II)
RMS measurement function / Accuracy
Sine wave: 20 Hz to 1 kHz, ±0.5% of F.S.
RMS measurement function / Number of channels
4 ch
Withstand voltage / Input to system bus/earth
2200 VAC (50/60 Hz) for 1 minute
Environmental resistance / Insulation resistance
500 VDC, 10 MΩ or more
[Direct input] Measurement terminal, GND terminal
42.4 Vpeak and 30 Vrms, or 60 VDC *3
[When using OP-88998 10:1 voltage-resistant probe] Measurement terminal
700 Vrms (CAT II), GND terminal: 300 Vrms (CAT II)

Compatibility Information

Match NR-HV04 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing NR-HV04.

Maintenance Tips

Store NR-HV04 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114