The KEYENCE NR-HV04 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- 0.05% of F.S., LPF: PASS (typ.)
- A/D converting system: Successive approximation, simultaneous sampling of all channels
- A/D resolution: 14 bit
- Ambient temperature: 0 to +40°C 32°F to 104°F
- Buffer memory: 16M data *4
- Calculationfunction: CH1 to CH2, CH3 to CH4 (Single-channel usage not possible when using the calculation function)
- Common mode noise reduction ratio: 80 dB or more (at max. 60 Hz DC) (typ.)
- Connector format: Insulated BNC connector
- Crest factor: 4 or less
- Digital filter: Averaging rate: 1 to 128 (automatically selected)
- Display resolution: ±1000 V: 50 mV ±500 V: 20 mV ±200 V: 10 mV ±100 V: 5 mV ±50 V: 2 mV ±20 V: 1 mV ±10 V: 0.5 mV ±5 V: 0.2 mV ±2 V: 0.1 mV
- Environmental resistance / Insulation resistance: 500 VDC, 10 MΩ or more
- Input coupling: AC/DC/AC-RMS/DC-RMS
- Input frequency band: 250 kHz (−3 dB or more)
- Input impedance: 1 MΩ ±1%, approx. 30 pF
- Input method: Insulated single-end input, channels insulated from each other, input channels insulated from other units (PC)
- Input type: ±1000 V, ±500 V, ±200 V, ±100 V, ±50 V, ±20 V, ±10 V, ±5 V, ±2 V
- Low pass filter: PASS, 7 Hz, 500 Hz, 50 kHz (−12 dB/oct)
- Maximum allowable voltage to ground: [When using OP-89263 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II)
- Maximum input voltage: [When using OP-89263 1:1 voltage-resistant probe] 1000 V peak and 700 Vrms, or 700 VDC
- Measurable range: ±1000 V: −1000.00 to +1000.00 V ±500 V: −550.00 to +550.00 V ±200 V: −220.00 to +220.00 V ±100 V: −110.000 to +110.000 V ±50 V: −55.000 to +55.000 V ±20 V: −22.000 to +22.000 V ±10 V: −11.0000 to +11.0000 V ±5 V: −5.5000 to +5.5000 V ±2 V: −2.2000 to +2.2000 V
- Measurement accuracy: ±0.1% of F.S., LPF: 500 Hz, with digital filter ON
- Measurement cycle: Maximum sampling cycle: 1 μs (1 MHz) to 60 s
- Number of channels: 4 ch *2
- RMS measurement function / Accuracy: Sine wave: 20 Hz to 1 kHz, ±0.5% of F.S.
- RMS measurement function / Number of channels: 4 ch
- Rating / Power consumption: 3 W or less
- Relative humidity: 10 to 85% RH (no condensation)
- Residual noise level: 0.01% of F.S., LPF: 500 Hz (200 μs/S, digital filter: ON) (typ.)
- Response time: 500 ms
- Type: High-speed, high-voltage measurement unit
- Warm up time: 30 minutes or more
- Weight: Approx. 270 g 9.53 oz
- Withstand voltage / Input to system bus/earth: 2200 VAC (50/60 Hz) for 1 minute
- [Direct input] Measurement terminal, GND terminal: 42.4 Vpeak and 30 Vrms, or 60 VDC *3
- [When using OP-88998 10:1 voltage-resistant probe] Measurement terminal: 700 Vrms (CAT II), GND terminal: 300 Vrms (CAT II)
Condition and supply
- New surplus, never used
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number NR-HV04 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- NR-HV04
- Brand
- KEYENCE
- Part Number
- NR-HV04
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Type
- High-speed, high-voltage measurement unit
- Weight
- Approx. 270 g 9.53 oz
- Packaging
- New surplus, never used
- Input type
- ±1000 V, ±500 V, ±200 V, ±100 V, ±50 V, ±20 V, ±10 V, ±5 V, ±2 V
- Crest factor
- 4 or less
- Input method
- Insulated single-end input, channels insulated from each other, input channels insulated from other units (PC)
- Warm up time
- 30 minutes or more
- Buffer memory
- 16M data *4
- Response time
- 500 ms
- A/D resolution
- 14 bit
- Digital filter
- Averaging rate: 1 to 128 (automatically selected)
- Input coupling
- AC/DC/AC-RMS/DC-RMS
- Input impedance
- 1 MΩ ±1%, approx. 30 pF
- Low pass filter
- PASS, 7 Hz, 500 Hz, 50 kHz (−12 dB/oct)
- Connector format
- Insulated BNC connector
- Measurable range
- ±1000 V: −1000.00 to +1000.00 V ±500 V: −550.00 to +550.00 V ±200 V: −220.00 to +220.00 V ±100 V: −110.000 to +110.000 V ±50 V: −55.000 to +55.000 V ±20 V: −22.000 to +22.000 V ±10 V: −11.0000 to +11.0000 V ±5 V: −5.5000 to +5.5000 V ±2 V: −2.2000 to +2.2000 V
- Measurement cycle
- Maximum sampling cycle: 1 μs (1 MHz) to 60 s
- Relative humidity
- 10 to 85% RH (no condensation)
- 0.05% of F.S., LPF
- PASS (typ.)
- Display resolution
- ±1000 V: 50 mV ±500 V: 20 mV ±200 V: 10 mV ±100 V: 5 mV ±50 V: 2 mV ±20 V: 1 mV ±10 V: 0.5 mV ±5 V: 0.2 mV ±2 V: 0.1 mV
- Number of channels
- 4 ch *2
- Ambient temperature
- 0 to +40°C 32°F to 104°F
- Calculationfunction
- CH1 to CH2, CH3 to CH4 (Single-channel usage not possible when using the calculation function)
- Input frequency band
- 250 kHz (−3 dB or more)
- Measurement accuracy
- ±0.1% of F.S., LPF: 500 Hz, with digital filter ON
- Residual noise level
- 0.01% of F.S., LPF: 500 Hz (200 μs/S, digital filter: ON) (typ.)
- A/D converting system
- Successive approximation, simultaneous sampling of all channels
- Maximum input voltage
- [When using OP-89263 1:1 voltage-resistant probe] 1000 V peak and 700 Vrms, or 700 VDC
- Rating / Power consumption
- 3 W or less
- Common mode noise reduction ratio
- 80 dB or more (at max. 60 Hz DC) (typ.)
- Maximum allowable voltage to ground
- [When using OP-89263 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II)
- RMS measurement function / Accuracy
- Sine wave: 20 Hz to 1 kHz, ±0.5% of F.S.
- RMS measurement function / Number of channels
- 4 ch
- Withstand voltage / Input to system bus/earth
- 2200 VAC (50/60 Hz) for 1 minute
- Environmental resistance / Insulation resistance
- 500 VDC, 10 MΩ or more
- [Direct input] Measurement terminal, GND terminal
- 42.4 Vpeak and 30 Vrms, or 60 VDC *3
- [When using OP-88998 10:1 voltage-resistant probe] Measurement terminal
- 700 Vrms (CAT II), GND terminal: 300 Vrms (CAT II)
Compatibility Information
Match NR-HV04 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing NR-HV04.
Maintenance Tips
Store NR-HV04 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. NR-HV04 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
NR-HV04 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match NR-HV04 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114