+86 13348028050
NR-FV04 KEYENCE NR-FV04 - Front View | Vcocnc FANUC Parts

KEYENCE NR-FV04

Product information

$1,604.78 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: NR-FV04

Alternate: NRFV04

Brand
KEYENCE
Part No.
NR-FV04
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE NR-FV04 Product overview The KEYENCE NR-FV04 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - 0.05% of F.S., LPF: PASS - A/D converting system: Successive approximation, simultaneous sampling of all channels - A/D resolution: 14 bit - Buffer memory: 16M data *4 - Common mode noise reduction ratio: 80 dB or more (at up to 60 Hz DC) - Connector format: Insulated BNC connector - Digital filter: Pulse frequency: Averaging rate of 1 to 32768 (automatically selected), Pulse count: None - Hysteresis: AUTO, 100 mV, 500 mV, 5 V - Input coupling: DC rising edge, DC falling edge, AC rising edge, AC falling edge - Input frequency band: 250 kHz (−3 dB or more) - Input impedance: 1 MΩ ±1%, approx. 30 pF - Input method: Insulated single-end input, channels insulated from each other, input channels insulated from other units (PC) - Low pass filter: PASS, 1.5 kHz, 15 kHz, 50 kHz - Maximum allowable voltage to ground: [When using OP-89263 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II) - Maximum input voltage: ±700 V *3 - Measurement accuracy / Pulse frequency: ±0.07% of rdg, ±0.01 Hz (20 Hz to 15 kHz, 20 ms/S, with digital filter ON) - Measurement cycle: Maximum sampling cycle: 1 μs (1 MHz) to 60 s - Measurement range / Pulse frequency: Measurable range: 0.05 to 16000.00 Hz, Display resolution: 0.01 to 1.00 Hz (selected automatically according to frequency) - Minimum pulse duration: 2 μs or more for both ON and OFF - Number of channels: 4 ch *2 - Predictive functions: Predictive calculation, Stop prediction (OFF, ×1.5, ×3, ×5, ×8, ×16) - Pulse count: Measurable range: 0 to 65,000 counts/sampling cycle, Display resolution: 1 count - Pulse divisions: 1 to 64 (Can be set to units of 1 division) - Pulse input / Input type: Pulse frequency, pulse count (Single-phase input) - Residual noise level: 0.02% of F.S., LPF: 1.5 kHz (200 μs/S, digital filter: ON) - Sensor power output: Dedicated connectors for OP-88003 (AUX POWER) × 2 when using OP-88003 - Threshold voltage: +100 V, +50 V, +20 V, +10 V, +5 V, +2.5 V, +1 V, +500 mV, +250 mV, +100 mV, +50 mV, 0 V - Type: Pulse measurement unit - Voltage input: ±0.1% of F.S., LPF: 500 Hz, with digital filter ON - Voltage input / Input type: ±100 V, ±50 V, ±20 V, ±10 V, ±5 V, ±2 V - Warm up time: 30 minutes or more - Withstand voltage / Input to system bus/earth: 2200 VAC (50/60 Hz) for 1 minute - [Direct input] Measurement terminal, GND terminal: 42.4 Vpeak and 30 Vrms, or 60 VDC *3 - [When using OP-88998 10:1 voltage-resistant probe] Measurement terminal: 700 Vrms (CAT II), GND terminal: 300 Vrms (CAT II) - ±10 V: Measurable range: −11.0000 to +11.0000 V, Display resolution: 0.5 mV - ±100 V: Measurable range: −110.000 to +110.000 V, Display resolution: 5 mV - ±2 V: Measurable range: −2.2000 to +2.2000 V, Display resolution: 0.1 mV - ±20 V: Measurable range: −22.000 to +22.000 V, Display resolution: 1 mV - ±5 V: Measurable range: −5.5000 to +5.5000 V, Display resolution: 0.2 mV - ±50 V: Measurable range: −55.000 to +55.000 V, Display resolution: 2 mV Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number NR-FV04 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
NR-FV04
Brand
KEYENCE
Part Number
NR-FV04
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
Pulse measurement unit
±2 V
Measurable range: −2.2000 to +2.2000 V, Display resolution: 0.1 mV
±5 V
Measurable range: −5.5000 to +5.5000 V, Display resolution: 0.2 mV
±10 V
Measurable range: −11.0000 to +11.0000 V, Display resolution: 0.5 mV
±20 V
Measurable range: −22.000 to +22.000 V, Display resolution: 1 mV
±50 V
Measurable range: −55.000 to +55.000 V, Display resolution: 2 mV
±100 V
Measurable range: −110.000 to +110.000 V, Display resolution: 5 mV
Packaging
New surplus, never used
Hysteresis
AUTO, 100 mV, 500 mV, 5 V
Pulse count
Measurable range: 0 to 65,000 counts/sampling cycle, Display resolution: 1 count
Input method
Insulated single-end input, channels insulated from each other, input channels insulated from other units (PC)
Warm up time
30 minutes or more
Buffer memory
16M data *4
Voltage input
±0.1% of F.S., LPF: 500 Hz, with digital filter ON
A/D resolution
14 bit
Digital filter
Pulse frequency: Averaging rate of 1 to 32768 (automatically selected), Pulse count: None
Input coupling
DC rising edge, DC falling edge, AC rising edge, AC falling edge
Input impedance
1 MΩ ±1%, approx. 30 pF
Low pass filter
PASS, 1.5 kHz, 15 kHz, 50 kHz
Pulse divisions
1 to 64 (Can be set to units of 1 division)
Connector format
Insulated BNC connector
Measurement cycle
Maximum sampling cycle: 1 μs (1 MHz) to 60 s
Threshold voltage
+100 V, +50 V, +20 V, +10 V, +5 V, +2.5 V, +1 V, +500 mV, +250 mV, +100 mV, +50 mV, 0 V
0.05% of F.S., LPF
PASS
Number of channels
4 ch *2
Sensor power output
Dedicated connectors for OP-88003 (AUX POWER) × 2 when using OP-88003
Input frequency band
250 kHz (−3 dB or more)
Predictive functions
Predictive calculation, Stop prediction (OFF, ×1.5, ×3, ×5, ×8, ×16)
Residual noise level
0.02% of F.S., LPF: 1.5 kHz (200 μs/S, digital filter: ON)
A/D converting system
Successive approximation, simultaneous sampling of all channels
Maximum input voltage
±700 V *3
Minimum pulse duration
2 μs or more for both ON and OFF
Pulse input / Input type
Pulse frequency, pulse count (Single-phase input)
Voltage input / Input type
±100 V, ±50 V, ±20 V, ±10 V, ±5 V, ±2 V
Common mode noise reduction ratio
80 dB or more (at up to 60 Hz DC)
Maximum allowable voltage to ground
[When using OP-89263 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II)
Measurement range / Pulse frequency
Measurable range: 0.05 to 16000.00 Hz, Display resolution: 0.01 to 1.00 Hz (selected automatically according to frequency)
Measurement accuracy / Pulse frequency
±0.07% of rdg, ±0.01 Hz (20 Hz to 15 kHz, 20 ms/S, with digital filter ON)
Withstand voltage / Input to system bus/earth
2200 VAC (50/60 Hz) for 1 minute
[Direct input] Measurement terminal, GND terminal
42.4 Vpeak and 30 Vrms, or 60 VDC *3
[When using OP-88998 10:1 voltage-resistant probe] Measurement terminal
700 Vrms (CAT II), GND terminal: 300 Vrms (CAT II)

Compatibility Information

Match NR-FV04 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing NR-FV04.

Maintenance Tips

Store NR-FV04 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114