KEYENCE NR-FV04
Product information
$1,604.78 USD
Condition: newShipping calculated at checkout ( Shipping Policy · 30-Day Returns )
SKU: NR-FV04
Alternate: NRFV04
Brand
KEYENCE
Part No.
NR-FV04
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
KEYENCE NR-FV04
Product overview
The KEYENCE NR-FV04 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- 0.05% of F.S., LPF: PASS
- A/D converting system: Successive approximation, simultaneous sampling of all channels
- A/D resolution: 14 bit
- Buffer memory: 16M data *4
- Common mode noise reduction ratio: 80 dB or more (at up to 60 Hz DC)
- Connector format: Insulated BNC connector
- Digital filter: Pulse frequency: Averaging rate of 1 to 32768 (automatically selected), Pulse count: None
- Hysteresis: AUTO, 100 mV, 500 mV, 5 V
- Input coupling: DC rising edge, DC falling edge, AC rising edge, AC falling edge
- Input frequency band: 250 kHz (−3 dB or more)
- Input impedance: 1 MΩ ±1%, approx. 30 pF
- Input method: Insulated single-end input, channels insulated from each other, input channels insulated from other units (PC)
- Low pass filter: PASS, 1.5 kHz, 15 kHz, 50 kHz
- Maximum allowable voltage to ground: [When using OP-89263 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II)
- Maximum input voltage: ±700 V *3
- Measurement accuracy / Pulse frequency: ±0.07% of rdg, ±0.01 Hz (20 Hz to 15 kHz, 20 ms/S, with digital filter ON)
- Measurement cycle: Maximum sampling cycle: 1 μs (1 MHz) to 60 s
- Measurement range / Pulse frequency: Measurable range: 0.05 to 16000.00 Hz, Display resolution: 0.01 to 1.00 Hz (selected automatically according to frequency)
- Minimum pulse duration: 2 μs or more for both ON and OFF
- Number of channels: 4 ch *2
- Predictive functions: Predictive calculation, Stop prediction (OFF, ×1.5, ×3, ×5, ×8, ×16)
- Pulse count: Measurable range: 0 to 65,000 counts/sampling cycle, Display resolution: 1 count
- Pulse divisions: 1 to 64 (Can be set to units of 1 division)
- Pulse input / Input type: Pulse frequency, pulse count (Single-phase input)
- Residual noise level: 0.02% of F.S., LPF: 1.5 kHz (200 μs/S, digital filter: ON)
- Sensor power output: Dedicated connectors for OP-88003 (AUX POWER) × 2 when using OP-88003
- Threshold voltage: +100 V, +50 V, +20 V, +10 V, +5 V, +2.5 V, +1 V, +500 mV, +250 mV, +100 mV, +50 mV, 0 V
- Type: Pulse measurement unit
- Voltage input: ±0.1% of F.S., LPF: 500 Hz, with digital filter ON
- Voltage input / Input type: ±100 V, ±50 V, ±20 V, ±10 V, ±5 V, ±2 V
- Warm up time: 30 minutes or more
- Withstand voltage / Input to system bus/earth: 2200 VAC (50/60 Hz) for 1 minute
- [Direct input] Measurement terminal, GND terminal: 42.4 Vpeak and 30 Vrms, or 60 VDC *3
- [When using OP-88998 10:1 voltage-resistant probe] Measurement terminal: 700 Vrms (CAT II), GND terminal: 300 Vrms (CAT II)
- ±10 V: Measurable range: −11.0000 to +11.0000 V, Display resolution: 0.5 mV
- ±100 V: Measurable range: −110.000 to +110.000 V, Display resolution: 5 mV
- ±2 V: Measurable range: −2.2000 to +2.2000 V, Display resolution: 0.1 mV
- ±20 V: Measurable range: −22.000 to +22.000 V, Display resolution: 1 mV
- ±5 V: Measurable range: −5.5000 to +5.5000 V, Display resolution: 0.2 mV
- ±50 V: Measurable range: −55.000 to +55.000 V, Display resolution: 2 mV
Condition and supply
- New surplus, never used
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number NR-FV04 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- NR-FV04
- Brand
- KEYENCE
- Part Number
- NR-FV04
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Type
- Pulse measurement unit
- ±2 V
- Measurable range: −2.2000 to +2.2000 V, Display resolution: 0.1 mV
- ±5 V
- Measurable range: −5.5000 to +5.5000 V, Display resolution: 0.2 mV
- ±10 V
- Measurable range: −11.0000 to +11.0000 V, Display resolution: 0.5 mV
- ±20 V
- Measurable range: −22.000 to +22.000 V, Display resolution: 1 mV
- ±50 V
- Measurable range: −55.000 to +55.000 V, Display resolution: 2 mV
- ±100 V
- Measurable range: −110.000 to +110.000 V, Display resolution: 5 mV
- Packaging
- New surplus, never used
- Hysteresis
- AUTO, 100 mV, 500 mV, 5 V
- Pulse count
- Measurable range: 0 to 65,000 counts/sampling cycle, Display resolution: 1 count
- Input method
- Insulated single-end input, channels insulated from each other, input channels insulated from other units (PC)
- Warm up time
- 30 minutes or more
- Buffer memory
- 16M data *4
- Voltage input
- ±0.1% of F.S., LPF: 500 Hz, with digital filter ON
- A/D resolution
- 14 bit
- Digital filter
- Pulse frequency: Averaging rate of 1 to 32768 (automatically selected), Pulse count: None
- Input coupling
- DC rising edge, DC falling edge, AC rising edge, AC falling edge
- Input impedance
- 1 MΩ ±1%, approx. 30 pF
- Low pass filter
- PASS, 1.5 kHz, 15 kHz, 50 kHz
- Pulse divisions
- 1 to 64 (Can be set to units of 1 division)
- Connector format
- Insulated BNC connector
- Measurement cycle
- Maximum sampling cycle: 1 μs (1 MHz) to 60 s
- Threshold voltage
- +100 V, +50 V, +20 V, +10 V, +5 V, +2.5 V, +1 V, +500 mV, +250 mV, +100 mV, +50 mV, 0 V
- 0.05% of F.S., LPF
- PASS
- Number of channels
- 4 ch *2
- Sensor power output
- Dedicated connectors for OP-88003 (AUX POWER) × 2 when using OP-88003
- Input frequency band
- 250 kHz (−3 dB or more)
- Predictive functions
- Predictive calculation, Stop prediction (OFF, ×1.5, ×3, ×5, ×8, ×16)
- Residual noise level
- 0.02% of F.S., LPF: 1.5 kHz (200 μs/S, digital filter: ON)
- A/D converting system
- Successive approximation, simultaneous sampling of all channels
- Maximum input voltage
- ±700 V *3
- Minimum pulse duration
- 2 μs or more for both ON and OFF
- Pulse input / Input type
- Pulse frequency, pulse count (Single-phase input)
- Voltage input / Input type
- ±100 V, ±50 V, ±20 V, ±10 V, ±5 V, ±2 V
- Common mode noise reduction ratio
- 80 dB or more (at up to 60 Hz DC)
- Maximum allowable voltage to ground
- [When using OP-89263 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II)
- Measurement range / Pulse frequency
- Measurable range: 0.05 to 16000.00 Hz, Display resolution: 0.01 to 1.00 Hz (selected automatically according to frequency)
- Measurement accuracy / Pulse frequency
- ±0.07% of rdg, ±0.01 Hz (20 Hz to 15 kHz, 20 ms/S, with digital filter ON)
- Withstand voltage / Input to system bus/earth
- 2200 VAC (50/60 Hz) for 1 minute
- [Direct input] Measurement terminal, GND terminal
- 42.4 Vpeak and 30 Vrms, or 60 VDC *3
- [When using OP-88998 10:1 voltage-resistant probe] Measurement terminal
- 700 Vrms (CAT II), GND terminal: 300 Vrms (CAT II)
Compatibility Information
Match NR-FV04 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing NR-FV04.
Maintenance Tips
Store NR-FV04 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. NR-FV04 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
NR-FV04 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match NR-FV04 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114