+86 13348028050
NR-CA04 KEYENCE NR-CA04 - Front View | Vcocnc FANUC Parts

KEYENCE NR-CA04

Product information

$3,790.80 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: NR-CA04

Alternate: NRCA04

Brand
KEYENCE
Part No.
NR-CA04
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE NR-CA04 Product overview The KEYENCE NR-CA04 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - A/D converting system: Delta-sigma method, simultaneous sampling of all channels - A/D resolution: 24 bit - Connector format: Charge output sensor input: Miniature (10-32UNF) - DC/DC-RMS: 45 kHz DC max. (±0.5 dB) - Input coupling / Sensor input: Charge output / Voltage output (built-in pre-amplifier) / Charge output - RMS / Voltage output (built-in pre-amplifier) - RMS - Input frequency band / Electric charge output type: 1.5 Hz (−3 dB typ.) to 45 kHz (±0.5 dB) - Input impedance: 100 kΩ ±1%, approx. 38 pF - Input method: Charge output sensor input / Single-end input, channels not insulated from each other - Input type / Sensor input: ±50000 m/s 2 ±164042.0 ft/s 2 , ±20000 m/s 2 ±65616.8 ft/s 2 , ±10000 m/s 2 ±32808.4 ft/s 2 , ±5000 m/s 2 ±16404.2 ft/s 2 , ±2000 m/s 2 ±6561.7 ft/s 2 , ±1000 m/s 2 ±3280.8 ft/s 2 , ±500 m/s 2 ±1640.4 ft/s 2 , ±200 m/s 2 ±656.2 ft/s 2 , ±100 m/s 2 ±328.1 ft/s 2 , ±50.0 m/s 2 ±164.0 ft/s 2 , ±20.0 m/s 2 ±65.6 ft/s 2 , ±10.0 m/s 2 ±32.8 ft/s 2 , ±5.00 m/s 2 ±16.4 ft/s 2 , ±2.00 m/s 2 ±6.6 ft/s 2 , ±1.00 m/s 2 ±3.3 ft/s 2 (with acceleration (unit setting: m/s 2 ft/s 2 )) - Low pass filter: PASS, 100 Hz, 1 kHz, 10 kHz (−12 dB/oct) - Maximum input rating: ±25 V - Measurement accuracy / Electric charge output type: ±0.9% of F.S. at [Sensor sensitivity] × [Setting range] ≥ 20 pC - Measurement cycle: Maximum sampling cycle: 10 µs (100 kHz) to 60 s - Measurement range / ±10 V: Measurable range: −11.0000 to +11.0000 V, Display resolution: 0.5 mV *3 - Number of channels: 4 ch *2 - Type: Acceleration measurement unit - Voltage: ±10 V to ±100 mV range: ±0.1% of F.S. ±50 mV range: ±0.15% of F.S., LPF: 100 Hz - Voltage input: ±10 V, ±5 V, ±2 V, ±1 V, ±500 mV, ±200 mV, ±100 mV, ±50 mV - Voltage input/output (built-in pre-amplifier) Sensor input: Non-insulated BNC connector - Voltage output type (with built-in preamplifier): ±0.25% of F.S. at [Sensor sensitivity] × [Setting range] ≥ 200 mV - Voltage output type (with built-in preamplifier) AC/AC-RMS: 1.0 Hz (−3 dB typ.) to 45 kHz (±0.5 dB) - Withstand voltage / Input to system bus/earth: 300 VAC (50/60 Hz) for 1 minute - ±1 V: Measurable range: −1.1000 to +1.1000 V, Display resolution: 50 μV *3 - ±100 m/s 2 ±328.1 ft/s 2: Measurable range: −110 to +11 - ±100 mV: Measurable range: −110.000 to +110.000 mV, Display resolution: 5 μV *3 - ±1000 m/s 2 ±3280.8 ft/s 2: Measurable range: −1100 to +1100 m/s 2 -3608.9 ft/s 2 to +3608.9 ft/s 2 , Display resolution: 0.05 m/s 2 0.16 ft/s 2 *3 - ±10000 m/s 2 ±32808.4 ft/s 2: Measurable range: −11000 to +11000 m/s 2 -36089.2 ft/s 2 to +36089.2 ft/s 2 , Display resolution: 0.5 m/s 2 1.6 ft/s 2 *3 - ±2 V: Measurable range: −2.2000 to +2.2000 V, Display resolution: 100 μV *3 - ±200 m/s 2 ±656.2 ft/s 2: Measurable range: −220 to +220 m/s 2 -728.1 ft/s 2 to +728.1 ft/s 2 , Display resolution: 0.01 m/s 2 0.03 ft/s 2 *3 - ±200 mV: Measurable range: −220.00 to +220.00 mV, Display resolution: 10 μV *3 - ±2000 m/s 2 ±6561.7 ft/s 2: Measurable range: −2200 to +2200 m/s 2 -7217.8 ft/s 2 to +7217.8 ft/s 2 , Display resolution: 0.1 m/s 2 0.3 ft/s 2 *3 - ±20000 m/s 2 ±65616.8 ft/s 2: Measurable range: −22000 to +22000 m/s 2 -72178.5 ft/s 2 to +72178.5 ft/s 2 , Display resolution: 1 m/s 2 3.3 ft/s 2 *3 - ±5 V: Measurable range: −5.5000 to +5.5000 V, Display resolution: 0.2 mV *3 - ±50 mV: Measurable range: −55.000 to +55.000 mV, Display resolution: 2 μV *3 - ±500 m/s 2 ±1640.4 ft/s 2: Measurable range: −550 to +550 m/s 2 -1804.5 ft/s 2 to +1804.5 ft/s 2 , Display resolution: 0.02 m/s 2 0.07 ft/s 2 *3 - ±500 mV: Measurable range: −550.00 to +550.00 mV, Display resolution: 20 μV *3 - ±5000 m/s 2 ±16404.2 ft/s 2: Measurable range: −5500 to +5500 m/s 2 -18044.6 ft/s 2 to +18044.6 ft/s 2 , Display resolution: 0.2 m/s 2 0.7 ft/s 2 *3 - ±50000 m/s 2 ±164042.0 ft/s 2: Measurable range: −55000 to +55000 m/s 2 -180446.2 ft/s 2 to +180446.2 ft/s 2 , Display resolution: 2 m/s 2 6.6 ft/s 2 *3 Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number NR-CA04 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
NR-CA04
Brand
KEYENCE
Part Number
NR-CA04
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
Acceleration measurement unit
±1 V
Measurable range: −1.1000 to +1.1000 V, Display resolution: 50 μV *3
±2 V
Measurable range: −2.2000 to +2.2000 V, Display resolution: 100 μV *3
±5 V
Measurable range: −5.5000 to +5.5000 V, Display resolution: 0.2 mV *3
Voltage
±10 V to ±100 mV range: ±0.1% of F.S. ±50 mV range: ±0.15% of F.S., LPF: 100 Hz
±50 mV
Measurable range: −55.000 to +55.000 mV, Display resolution: 2 μV *3
±100 mV
Measurable range: −110.000 to +110.000 mV, Display resolution: 5 μV *3
±200 mV
Measurable range: −220.00 to +220.00 mV, Display resolution: 10 μV *3
±500 mV
Measurable range: −550.00 to +550.00 mV, Display resolution: 20 μV *3
DC/DC-RMS
45 kHz DC max. (±0.5 dB)
Packaging
New surplus, never used
Input method
Charge output sensor input / Single-end input, channels not insulated from each other
Voltage input
±10 V, ±5 V, ±2 V, ±1 V, ±500 mV, ±200 mV, ±100 mV, ±50 mV
A/D resolution
24 bit
Input impedance
100 kΩ ±1%, approx. 38 pF
Low pass filter
PASS, 100 Hz, 1 kHz, 10 kHz (−12 dB/oct)
Connector format
Charge output sensor input: Miniature (10-32UNF)
Measurement cycle
Maximum sampling cycle: 10 µs (100 kHz) to 60 s
Number of channels
4 ch *2
Maximum input rating
±25 V
A/D converting system
Delta-sigma method, simultaneous sampling of all channels
Input type / Sensor input
±50000 m/s 2 ±164042.0 ft/s 2 , ±20000 m/s 2 ±65616.8 ft/s 2 , ±10000 m/s 2 ±32808.4 ft/s 2 , ±5000 m/s 2 ±16404.2 ft/s 2 , ±2000 m/s 2 ±6561.7 ft/s 2 , ±1000 m/s 2 ±3280.8 ft/s 2 , ±500 m/s 2 ±1640.4 ft/s 2 , ±200 m/s 2 ±656.2 ft/s 2 , ±100 m/s 2 ±328.1 ft/s 2 , ±50.0 m/s 2 ±164.0 ft/s 2 , ±20.0 m/s 2 ±65.6 ft/s 2 , ±10.0 m/s 2 ±32.8 ft/s 2 , ±5.00 m/s 2 ±16.4 ft/s 2 , ±2.00 m/s 2 ±6.6 ft/s 2 , ±1.00 m/s 2 ±3.3 ft/s 2 (with acceleration (unit setting: m/s 2 ft/s 2 ))
Measurement range / ±10 V
Measurable range: −11.0000 to +11.0000 V, Display resolution: 0.5 mV *3
±100 m/s 2 ±328.1 ft/s 2
Measurable range: −110 to +11
±200 m/s 2 ±656.2 ft/s 2
Measurable range: −220 to +220 m/s 2 -728.1 ft/s 2 to +728.1 ft/s 2 , Display resolution: 0.01 m/s 2 0.03 ft/s 2 *3
±500 m/s 2 ±1640.4 ft/s 2
Measurable range: −550 to +550 m/s 2 -1804.5 ft/s 2 to +1804.5 ft/s 2 , Display resolution: 0.02 m/s 2 0.07 ft/s 2 *3
±1000 m/s 2 ±3280.8 ft/s 2
Measurable range: −1100 to +1100 m/s 2 -3608.9 ft/s 2 to +3608.9 ft/s 2 , Display resolution: 0.05 m/s 2 0.16 ft/s 2 *3
±2000 m/s 2 ±6561.7 ft/s 2
Measurable range: −2200 to +2200 m/s 2 -7217.8 ft/s 2 to +7217.8 ft/s 2 , Display resolution: 0.1 m/s 2 0.3 ft/s 2 *3
Input coupling / Sensor input
Charge output / Voltage output (built-in pre-amplifier) / Charge output - RMS / Voltage output (built-in pre-amplifier) - RMS
±5000 m/s 2 ±16404.2 ft/s 2
Measurable range: −5500 to +5500 m/s 2 -18044.6 ft/s 2 to +18044.6 ft/s 2 , Display resolution: 0.2 m/s 2 0.7 ft/s 2 *3
±10000 m/s 2 ±32808.4 ft/s 2
Measurable range: −11000 to +11000 m/s 2 -36089.2 ft/s 2 to +36089.2 ft/s 2 , Display resolution: 0.5 m/s 2 1.6 ft/s 2 *3
±20000 m/s 2 ±65616.8 ft/s 2
Measurable range: −22000 to +22000 m/s 2 -72178.5 ft/s 2 to +72178.5 ft/s 2 , Display resolution: 1 m/s 2 3.3 ft/s 2 *3
±50000 m/s 2 ±164042.0 ft/s 2
Measurable range: −55000 to +55000 m/s 2 -180446.2 ft/s 2 to +180446.2 ft/s 2 , Display resolution: 2 m/s 2 6.6 ft/s 2 *3
Withstand voltage / Input to system bus/earth
300 VAC (50/60 Hz) for 1 minute
Voltage output type (with built-in preamplifier)
±0.25% of F.S. at [Sensor sensitivity] × [Setting range] ≥ 200 mV
Input frequency band / Electric charge output type
1.5 Hz (−3 dB typ.) to 45 kHz (±0.5 dB)
Measurement accuracy / Electric charge output type
±0.9% of F.S. at [Sensor sensitivity] × [Setting range] ≥ 20 pC
Voltage input/output (built-in pre-amplifier) Sensor input
Non-insulated BNC connector
Voltage output type (with built-in preamplifier) AC/AC-RMS
1.0 Hz (−3 dB typ.) to 45 kHz (±0.5 dB)

Compatibility Information

Match NR-CA04 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing NR-CA04.

Maintenance Tips

Store NR-CA04 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114