KEYENCE MS2-H50
Product information
$204.41 USD
Condition: newShipping calculated at checkout ( Shipping Policy · 30-Day Returns )
SKU: MS2-H50
Alternate: MS2H50
Brand
KEYENCE
Part No.
MS2-H50
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
KEYENCE MS2-H50
Product overview
The KEYENCE MS2-H50 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Ambient temperature: -10 to +55 °C 14 to 131 °F (No freezing) (see the derating characteristics)
- Applicable standards / Safety standards: UL: UL508, UL60950-1
- C-UL: CSA C22.2 number 14-M95, CSA C22.2 number 60950-1-03
- Cooling method: Natural air cooling
- Display / Display power: 3-digit 7-segment LED (character height: 10 mm 0.39" )
- Display resolution: 0.1A/0.4V /1%
- EMC standard: FCC Part 15 B Class A, EN55011 Class A, EN61000-6-2
- EN: EN60950-1, EN50178
- Efficiency (100/200 VAC): 82, 85% typ. (at 100% load)
- Environmental resistance / Insulation resistance: 100 MΩ or more at 500 VDC (between input and output, between input and FG, and between output and FG)
- Frequency: 47 to 63 Hz, DC *1
- IEC: IEC60950-1
- Input conditions / Input voltage: 85 to 264 VAC, 110 to 370 VDC *1
- Input fluctuation: 0.4% or less
- Inputconditions / Input current (100/200 VAC): 1.3/0.7A or less
- Leakage current (100/200 VAC): 0.4, 0.75 mA or less (at 100% load)
- Limits for harmonic current emissions: EN61000-3-2 *3
- Load fluctuation: 1.5% or less
- Other / Parallel operation: Possible (requires OP-42207) *4
- Output characteristics / Rated voltage: 24V
- Output holding time: 20 ms or more (when the ambient usage temperature is +25°C 77°F and with rated I/O conditions)
- Overvoltage protection: Activates at 26.4 V or more, voltage interruption method, recovers when input is applied again *2
- Power off memory time: Approx. 10 years (at +20°C 68°F )
- Protection / Overcurrent protection: Constant current drop method, automatic recovery, 2.7 A or more
- Rated current: 2.1A (Class2)
- Relative humidity: 25 to 85 % RH (No condensation)
- Ripple/noise voltage: 180mV (p-p) or less
- Rush current (100/200 VAC): 25, 50 A or less (at 100% load with a +25°C 77°F cold start)
- Series operation: Possible (requires external diode) *4
- Shock resistance: Peak acceleration: 300 m/s 2 , 2 times in each of the X, Y, and Z directions
- Startup time: 500 ms or less (when the ambient usage temperature is between 0 and +55°C 32 and 131°F with rated I/O conditions)
- Storage temperature: -20 to +70 °C -4 to 158 °F (No freezing)
- Temperature fluctuation: 0.02%/°C or less
- Variable voltage range: ±5% (with V.ADJ)
- Vibration resistance: 10 to 57 Hz, Double amplitude 0.3 mm 0.01" , 57 to 500 Hz, 19.6 m/s 2 (2 G), cycle: 5.5 minutes, 2 hours in each of the X, Y, and Z directions
- Weight: Approx. 270 g
- Withstand voltage: 3.0 kVAC, 50/60 Hz, 1 min (across input and output terminals) 2.0 kVAC, 50/60 Hz, 1min (across input terminals and PE terminal) 500 VAC, 50/60 Hz, 1min (across output terminals and PE terminal)
Condition and supply
- New surplus, factory sealed original packaging
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number MS2-H50 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- MS2-H50
- Brand
- KEYENCE
- Part Number
- MS2-H50
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- EN
- EN60950-1, EN50178
- IEC
- IEC60950-1
- C-UL
- CSA C22.2 number 14-M95, CSA C22.2 number 60950-1-03
- Weight
- Approx. 270 g
- Frequency
- 47 to 63 Hz, DC *1
- Packaging
- New surplus, factory sealed original packaging
- EMC standard
- FCC Part 15 B Class A, EN55011 Class A, EN61000-6-2
- Startup time
- 500 ms or less (when the ambient usage temperature is between 0 and +55°C 32 and 131°F with rated I/O conditions)
- Rated current
- 2.1A (Class2)
- Cooling method
- Natural air cooling
- Load fluctuation
- 1.5% or less
- Series operation
- Possible (requires external diode) *4
- Shock resistance
- Peak acceleration: 300 m/s 2 , 2 times in each of the X, Y, and Z directions
- Input fluctuation
- 0.4% or less
- Relative humidity
- 25 to 85 % RH (No condensation)
- Withstand voltage
- 3.0 kVAC, 50/60 Hz, 1 min (across input and output terminals) 2.0 kVAC, 50/60 Hz, 1min (across input terminals and PE terminal) 500 VAC, 50/60 Hz, 1min (across output terminals and PE terminal)
- Display resolution
- 0.1A/0.4V /1%
- Ambient temperature
- -10 to +55 °C 14 to 131 °F (No freezing) (see the derating characteristics)
- Output holding time
- 20 ms or more (when the ambient usage temperature is +25°C 77°F and with rated I/O conditions)
- Storage temperature
- -20 to +70 °C -4 to 158 °F (No freezing)
- Ripple/noise voltage
- 180mV (p-p) or less
- Vibration resistance
- 10 to 57 Hz, Double amplitude 0.3 mm 0.01" , 57 to 500 Hz, 19.6 m/s 2 (2 G), cycle: 5.5 minutes, 2 hours in each of the X, Y, and Z directions
- Power off memory time
- Approx. 10 years (at +20°C 68°F )
- Overvoltage protection
- Activates at 26.4 V or more, voltage interruption method, recovers when input is applied again *2
- Variable voltage range
- ±5% (with V.ADJ)
- Display / Display power
- 3-digit 7-segment LED (character height: 10 mm 0.39" )
- Temperature fluctuation
- 0.02%/°C or less
- Efficiency (100/200 VAC)
- 82, 85% typ. (at 100% load)
- Other / Parallel operation
- Possible (requires OP-42207) *4
- Rush current (100/200 VAC)
- 25, 50 A or less (at 100% load with a +25°C 77°F cold start)
- Leakage current (100/200 VAC)
- 0.4, 0.75 mA or less (at 100% load)
- Input conditions / Input voltage
- 85 to 264 VAC, 110 to 370 VDC *1
- Protection / Overcurrent protection
- Constant current drop method, automatic recovery, 2.7 A or more
- Limits for harmonic current emissions
- EN61000-3-2 *3
- Output characteristics / Rated voltage
- 24V
- Applicable standards / Safety standards
- UL: UL508, UL60950-1
- Inputconditions / Input current (100/200 VAC)
- 1.3/0.7A or less
- Environmental resistance / Insulation resistance
- 100 MΩ or more at 500 VDC (between input and output, between input and FG, and between output and FG)
Compatibility Information
Match MS2-H50 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing MS2-H50.
Maintenance Tips
Store MS2-H50 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. MS2-H50 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
MS2-H50 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match MS2-H50 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114