+86 13348028050
MS2-H150 KEYENCE MS2-H150 - Front View | Vcocnc FANUC Parts

KEYENCE MS2-H150

Product information

$292.17 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: MS2-H150

Alternate: MS2H150

Brand
KEYENCE
Part No.
MS2-H150
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE MS2-H150 Product overview The KEYENCE MS2-H150 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Ambient temperature: -10 to +55 °C 14 to 131 °F (No freezing) (see the derating characteristics) - Applicable standards / Safety standards: UL: UL508, UL60950-1 - C-UL: CSA C22.2 number 14-M95, CSA C22.2 number 60950-1-03 - Cooling method: Natural air cooling - Display / Display power: 3-digit 7-segment LED (character height: 10 mm 0.39" ) - Display resolution: 0.1A/0.4V /1% - EMC standard: FCC Part 15 B Class A, EN55011 Class A, EN61000-6-2 - EN: EN60950-1, EN50178 - Efficiency (100/200 VAC): 82, 85% typ. (at 100% load) - Environmental resistance / Insulation resistance: 100 MΩ or more at 500 VDC (between input and output, between input and FG, and between output and FG) - Frequency: 47 to 63 Hz, DC *1 - IEC: IEC60950-1 - Input conditions / Input voltage: 85 to 264 VAC, 110 to 370 VDC *1 - Input fluctuation: 0.4% or less - Inputconditions / Input current (100/200 VAC): 2.2/1.1A or less - Leakage current (100/200 VAC): 0.4, 0.75 mA or less (at 100% load) - Limits for harmonic current emissions: EN61000-3-2 *3 - Load fluctuation: 1.5% or less - Other / Parallel operation: Possible (requires OP-42207) *4 - Output characteristics / Rated voltage: 24V - Output holding time: 20 ms or more (when the ambient usage temperature is +25°C 77°F and with rated I/O conditions) - Overvoltage protection: Activates at 26.4 V or more, voltage interruption method, recovers when input is applied again *2 - Power off memory time: Approx. 10 years (at +20°C 68°F ) - Protection / Overcurrent protection: Constant current drop method, automatic recovery, 7.9 A or more - Rated current: 6.5A - Relative humidity: 25 to 85 % RH (No condensation) - Ripple/noise voltage: 180mV (p-p) or less - Rush current (100/200 VAC): 25, 50 A or less (at 100% load with a +25°C 77°F cold start) - Series operation: Possible (requires external diode) *4 - Shock resistance: Peak acceleration: 300 m/s 2 , 2 times in each of the X, Y, and Z directions - Startup time: 500 ms or less (when the ambient usage temperature is between 0 and +55°C 32 and 131°F with rated I/O conditions) - Storage temperature: -20 to +70 °C -4 to 158 °F (No freezing) - Temperature fluctuation: 0.02%/°C or less - Variable voltage range: ±5% (with V.ADJ) - Vibration resistance: 10 to 57 Hz, Double amplitude 0.3 mm 0.01" , 57 to 500 Hz, 19.6 m/s 2 (2 G), cycle: 5.5 minutes, 2 hours in each of the X, Y, and Z directions - Weight: Approx. 700 g - Withstand voltage: 3.0 kVAC, 50/60 Hz, 1 min (across input and output terminals) 2.0 kVAC, 50/60 Hz, 1min (across input terminals and PE terminal) 500 VAC, 50/60 Hz, 1min (across output terminals and PE terminal) Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number MS2-H150 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
MS2-H150
Brand
KEYENCE
Part Number
MS2-H150
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
EN
EN60950-1, EN50178
IEC
IEC60950-1
C-UL
CSA C22.2 number 14-M95, CSA C22.2 number 60950-1-03
Weight
Approx. 700 g
Frequency
47 to 63 Hz, DC *1
Packaging
New surplus, factory sealed original packaging
EMC standard
FCC Part 15 B Class A, EN55011 Class A, EN61000-6-2
Startup time
500 ms or less (when the ambient usage temperature is between 0 and +55°C 32 and 131°F with rated I/O conditions)
Rated current
6.5A
Cooling method
Natural air cooling
Load fluctuation
1.5% or less
Series operation
Possible (requires external diode) *4
Shock resistance
Peak acceleration: 300 m/s 2 , 2 times in each of the X, Y, and Z directions
Input fluctuation
0.4% or less
Relative humidity
25 to 85 % RH (No condensation)
Withstand voltage
3.0 kVAC, 50/60 Hz, 1 min (across input and output terminals) 2.0 kVAC, 50/60 Hz, 1min (across input terminals and PE terminal) 500 VAC, 50/60 Hz, 1min (across output terminals and PE terminal)
Display resolution
0.1A/0.4V /1%
Ambient temperature
-10 to +55 °C 14 to 131 °F (No freezing) (see the derating characteristics)
Output holding time
20 ms or more (when the ambient usage temperature is +25°C 77°F and with rated I/O conditions)
Storage temperature
-20 to +70 °C -4 to 158 °F (No freezing)
Ripple/noise voltage
180mV (p-p) or less
Vibration resistance
10 to 57 Hz, Double amplitude 0.3 mm 0.01" , 57 to 500 Hz, 19.6 m/s 2 (2 G), cycle: 5.5 minutes, 2 hours in each of the X, Y, and Z directions
Power off memory time
Approx. 10 years (at +20°C 68°F )
Overvoltage protection
Activates at 26.4 V or more, voltage interruption method, recovers when input is applied again *2
Variable voltage range
±5% (with V.ADJ)
Display / Display power
3-digit 7-segment LED (character height: 10 mm 0.39" )
Temperature fluctuation
0.02%/°C or less
Efficiency (100/200 VAC)
82, 85% typ. (at 100% load)
Other / Parallel operation
Possible (requires OP-42207) *4
Rush current (100/200 VAC)
25, 50 A or less (at 100% load with a +25°C 77°F cold start)
Leakage current (100/200 VAC)
0.4, 0.75 mA or less (at 100% load)
Input conditions / Input voltage
85 to 264 VAC, 110 to 370 VDC *1
Protection / Overcurrent protection
Constant current drop method, automatic recovery, 7.9 A or more
Limits for harmonic current emissions
EN61000-3-2 *3
Output characteristics / Rated voltage
24V
Applicable standards / Safety standards
UL: UL508, UL60950-1
Inputconditions / Input current (100/200 VAC)
2.2/1.1A or less
Environmental resistance / Insulation resistance
100 MΩ or more at 500 VDC (between input and output, between input and FG, and between output and FG)

Compatibility Information

Match MS2-H150 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing MS2-H150.

Maintenance Tips

Store MS2-H150 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114