+86 13348028050
MP-FG10R KEYENCE MP-FG10R - Front View | Vcocnc FANUC Parts

KEYENCE MP-FG10R

Product information

$3,313.13 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: MP-FG10R

Alternate: MPFG10R

Brand
KEYENCE
Part No.
MP-FG10R
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE MP-FG10R Product overview The KEYENCE MP-FG10R is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Ambient temperature: −5°C to +50°C 23°F to 122°F (no freezing) *11 - Analog output (Ch.1/2): 4 to 20 mA, load resistance: 260 Ω or less *4 - Averaging time: OFF/100 ms/200 ms/500 ms/1.0 s/3.0 s/5.0 s/10 s/30 s (selectable) - Check valve: Available - Communication interface: USB2.0 - Connection bore diameter: G3/8" (10 A) - Data accumulation / Accumulation period: Accumulated data: approx. 2 years/Instantaneous data: approx. 2 weeks - Data reading: USB 2.0/Ethernet - Display: Color LCD, status indicator - Display resolution: 0.1 L/min, 0.01 m 3 /h 0.35 ft 3 /h , 0.01 CFM - Drainage cup capacity: 60 cc - Environmental resistance / Enclosure rating: IP67 (IEC60529) *10 - External input (Ch.2/3/6): Short-circuit current: 1.5 mA or less, input time: 20 ms or more - Filter/regulator (Standard model only) / Pressure adjustment range: 0.15 to 0.90 MPa - Filtration degree: 5 μm 0.196850 Mil - Flow rate / Detection principle: Heat based (mass flow rate) - Humidity (Dew point) / Rated relative humidity range/ dew point range: 15 to 100%RH (no condensation)/Corresponds to the relative humidity range *5 *6 - I/O / Control output (Ch.1/2/3/4/5): NPN/PNP setting switchable, open collector output 30 VDC or less, N.O./N.C. setting switchable, max. 100 mA/Ch., residual voltage: 2.5 V or less - Leakage amount: 50 mL/min 0.002 CFM (N) or less - Measurement accuracy: ±(1.5% of RD + 0.5% of F.S.) *2 *3 - Network compatibility: When using only this unit: IO-Link (Specification v1.1/COM3) *9 When connecting MP-FEN1 : EtherNet/IP™, PROFINET, Modbus/TCP, MC protocol/SLMP - Operating pressure range: 0.2 to 1 MPa, 2 to 10 bar, 29 to 145 psi *1 - Power consumption: 1.2 A (300 ms) when opening/closing valve, 100 mA at all other times *8 (standalone usage - Power supply / Power voltage: 24 VDC +25%/-20% (including ripple), Class 2 or LPS - Pressure (Digital value, gauge pressure) / Rated pressure range: 0.000 to 1.000 MPa, 0.00 to 10.00bar, 0.0 to 145.0 psi - Pressure resistance: 1.5 MPa, 15 bar, 217.5 psi - Protection circuit: Power supply reverse connection protection, power supply surge protection, reverse connection protection for each I/O, surge protection for each I/O, overcurrent protection for each output - Rated flow range (normal): 2.0 to 1000.0 L/min 0.12 to 60.00 m 3 /h 4.24 to 2118.88 ft 3 /h 0.07 to 35.31 CFM - Relative humidity: 35%RH to 85%RH (no condensation) - Repeatability: ±1.0% of F.S. (with an averaging time of 1.0 s) - Response time: 150 ms (63% response) *4 - Shock resistance: 300 m/s 2 , XYZ axes, 10 times for each axis - Shut-off valve / Response time: 1 s or less (closed → open) - Supported gas temperature: -5 to +50°C, 23 to 122°F - Supported gases: Air and non-corrosive gases - Temperature / Measurement accuracy: ±2.0°C, ±3.6°F *7 - Type: Standard model - Vibration resistance: 10 to 500 Hz - Zero cut flow rate: 2.0 L/min, 0.12 m 3 /h 4.24 ft 3 /h , 0.07 CFM - power spectral density: 0.204 G 2 /Hz Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number MP-FG10R with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
MP-FG10R
Brand
KEYENCE
Part Number
MP-FG10R
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
Standard model
Display
Color LCD, status indicator
Packaging
New surplus, never used
Check valve
Available
Data reading
USB 2.0/Ethernet
Repeatability
±1.0% of F.S. (with an averaging time of 1.0 s)
Response time
150 ms (63% response) *4
Averaging time
OFF/100 ms/200 ms/500 ms/1.0 s/3.0 s/5.0 s/10 s/30 s (selectable)
Leakage amount
50 mL/min 0.002 CFM (N) or less
Supported gases
Air and non-corrosive gases
Shock resistance
300 m/s 2 , XYZ axes, 10 times for each axis
Filtration degree
5 μm 0.196850 Mil
Power consumption
1.2 A (300 ms) when opening/closing valve, 100 mA at all other times *8 (standalone usage
Relative humidity
35%RH to 85%RH (no condensation)
Display resolution
0.1 L/min, 0.01 m 3 /h 0.35 ft 3 /h , 0.01 CFM
Protection circuit
Power supply reverse connection protection, power supply surge protection, reverse connection protection for each I/O, surge protection for each I/O, overcurrent protection for each output
Zero cut flow rate
2.0 L/min, 0.12 m 3 /h 4.24 ft 3 /h , 0.07 CFM
Ambient temperature
−5°C to +50°C 23°F to 122°F (no freezing) *11
Pressure resistance
1.5 MPa, 15 bar, 217.5 psi
Measurement accuracy
±(1.5% of RD + 0.5% of F.S.) *2 *3
Vibration resistance
10 to 500 Hz
Drainage cup capacity
60 cc
Network compatibility
When using only this unit: IO-Link (Specification v1.1/COM3) *9 When connecting MP-FEN1 : EtherNet/IP™, PROFINET, Modbus/TCP, MC protocol/SLMP
Analog output (Ch.1/2)
4 to 20 mA, load resistance: 260 Ω or less *4
power spectral density
0.204 G 2 /Hz
Communication interface
USB2.0
Connection bore diameter
G3/8" (10 A)
Operating pressure range
0.2 to 1 MPa, 2 to 10 bar, 29 to 145 psi *1
External input (Ch.2/3/6)
Short-circuit current: 1.5 mA or less, input time: 20 ms or more
Rated flow range (normal)
2.0 to 1000.0 L/min 0.12 to 60.00 m 3 /h 4.24 to 2118.88 ft 3 /h 0.07 to 35.31 CFM
Supported gas temperature
-5 to +50°C, 23 to 122°F
Power supply / Power voltage
24 VDC +25%/-20% (including ripple), Class 2 or LPS
Shut-off valve / Response time
1 s or less (closed → open)
Flow rate / Detection principle
Heat based (mass flow rate)
Temperature / Measurement accuracy
±2.0°C, ±3.6°F *7
I/O / Control output (Ch.1/2/3/4/5)
NPN/PNP setting switchable, open collector output 30 VDC or less, N.O./N.C. setting switchable, max. 100 mA/Ch., residual voltage: 2.5 V or less
Data accumulation / Accumulation period
Accumulated data: approx. 2 years/Instantaneous data: approx. 2 weeks
Environmental resistance / Enclosure rating
IP67 (IEC60529) *10
Pressure (Digital value, gauge pressure) / Rated pressure range
0.000 to 1.000 MPa, 0.00 to 10.00bar, 0.0 to 145.0 psi
Filter/regulator (Standard model only) / Pressure adjustment range
0.15 to 0.90 MPa
Humidity (Dew point) / Rated relative humidity range/ dew point range
15 to 100%RH (no condensation)/Corresponds to the relative humidity range *5 *6

Compatibility Information

Match MP-FG10R against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing MP-FG10R.

Maintenance Tips

Store MP-FG10R dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114