KEYENCE MP-FEA1
Product information
$968.93 USD
Condition: newShipping calculated at checkout ( Shipping Policy · 30-Day Returns )
SKU: MP-FEA1
Alternate: MPFEA1
Brand
KEYENCE
Part No.
MP-FEA1
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
KEYENCE MP-FEA1
Product overview
The KEYENCE MP-FEA1 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- 1-phase 3-wire: ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 240 VAC (L-N), 200 to 480 VAC (L-L) ・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N), 200 to 480 VAC (L-L)
- 3-phase 3-wire: ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 173 to 480 VAC (L-L) ・MP-FEC50M/MP-FEC100M in use: 173 to 240 VAC (L-L)
- 3-phase 4-wire: ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 277 VAC (L-N), 173 to 480 VAC (L-L) ・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N), 173 to 415 VAC (L-L)
- Active energy: ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: Compliant with IEC 62053-22 §7.9 table 3 class 0.5 *2 *3 Power factor 1: ±0.5% of RD (5% ≤ In ≤ 120%), ±1.0% of RD (1% ≤ In < 5%) Power factor 0.5 inductive: ±0.6% of RD (10% ≤ In ≤ 120%), ±1.0% of RD (2% ≤ In < 10%) Power factor 0.8 capacitive: ±0.6% of RD (10% ≤ In ≤ 120%), ±1.0% of RD (2% ≤ In < 10%) ・MP-FEC50M/MP-FEC100M in use: ±1.0% of RD (1% ≤ In ≤ 120%) *3
- Active energy/reactive energy/apparent energy: 0.000 to 999999.999 [kWh/kvarh/kVAh], display resolution 0.001 [kWh/kvarh/kVAh]
- Active power/reactive power/apparent power: -8942.400 to +8942.400 [kW/kvar/kVA], display resolution 0.001 [kW/kvar/kVA]
- Apparent energy: ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: ±0.5% of RD (5% ≤ In ≤ 120%), ±1.0% of RD (1% ≤ In < 5%) *2 *3 ・MP-FEC50M/MP-FEC100M in use: ±1.0% of RD (5% ≤ In ≤ 120%) *3 *4
- Current: Display resolution 0.001 [A]
- Current consumption: 36 mA
- Displayable range/ Display resolution (Main Unit) / Voltage: Display resolution 0.1 [V]
- Effect of ambient temperature: ±0.03%/K *3 *5
- Effect of harmonics: ±0.5% of RD *3 *6
- Frequency: 0.0 to 90.0 [Hz], display resolution 0.1 [Hz]
- Input specifications / Primary-side rated current, In: When using specialized CT MP-FEC100: 100 A Or, general CT (secondary-side rated input current 1 A) *2 When using specialized CT MP-FEC250: 250 A Or, general CT (secondary-side rated input current 1 A) *2 When using specialized CT MP-FEC600: 600 A Or, general CT (secondary-side rated input current 1 A) *2 When using specialized CT MP-FEC50M: 50 A When using specialized CT MP-FEC100M: 100 A
- Input voltage fluctuation range: −15% to +15% of the rated input voltage
- Insulation resistance: Across all terminals and housing: 20 MΩ min. (500 VDC) Across voltage measurement term
- Maximum permissible voltage to earth: ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 480 VAC to earth ・MP-FEC50M/MP-FEC100M in use: 240 VAC to earth
- Measurement accuracy / Voltage: ±0.5% of RD (within rated input voltage) *3
- Measurement specifications / Electrical service type: 1-phase 2-wire, 1-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire (switchable)
- Number of measurement circuits: 1 (up to 2 circuits with the 1-phase 2-wire setting *1 )
- Over current withstand capability: 1.2 times the primary-side rated current (can be applied consecutively), 10 times the primary-side rated current (for 1 second or less)
- Power: ±0.1 [Hz] *3
- Power factor (PF): -1.00 to 1.00, display resolution 0.01
- Rated input frequency: 50/60 Hz
- Rated input voltage (direct input) / 1-phase 2-wire: ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 277 VAC (L-N) ・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N)
- Reactive energy: ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: Compliant with IEC 62053-23 §7.9 table 3 class 2 *2 *3 Reactive power factor 1: ±2.0% of RD (5% ≤ In ≤ 120%), ±2.5% of RD (1% ≤ In < 5%) Reactive power factor 0.5 inductive or capacitive: ±2.0% of RD (10% ≤ In ≤ 120%), ±2.5% of RD (5% ≤ In < 10%) Reactive power factor 0.25 inductive or capacitive: ±2.5% of RD (10% ≤ In ≤ 120%) ・MP-FEC50M/MP-FEC100M in use: ±2.0% of RD (5% ≤ In ≤ 120%) *3
- Withstand voltage: Across all terminals and housing: 2500 VAC for 1 minute Across voltage measurement terminal and communication terminal: 2500 VAC for 1 minute Across CT input terminal and communication terminal (When using a specialized CT): 2500 V for 1 minute
Condition and supply
- New surplus, never used
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number MP-FEA1 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- MP-FEA1
- Brand
- KEYENCE
- Part Number
- MP-FEA1
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Power
- ±0.1 [Hz] *3
- Current
- Display resolution 0.001 [A]
- Frequency
- 0.0 to 90.0 [Hz], display resolution 0.1 [Hz]
- Packaging
- New surplus, never used
- Active energy
- ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: Compliant with IEC 62053-22 §7.9 table 3 class 0.5 *2 *3 Power factor 1: ±0.5% of RD (5% ≤ In ≤ 120%), ±1.0% of RD (1% ≤ In < 5%) Power factor 0.5 inductive: ±0.6% of RD (10% ≤ In ≤ 120%), ±1.0% of RD (2% ≤ In < 10%) Power factor 0.8 capacitive: ±0.6% of RD (10% ≤ In ≤ 120%), ±1.0% of RD (2% ≤ In < 10%) ・MP-FEC50M/MP-FEC100M in use: ±1.0% of RD (1% ≤ In ≤ 120%) *3
- 1-phase 3-wire
- ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 240 VAC (L-N), 200 to 480 VAC (L-L) ・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N), 200 to 480 VAC (L-L)
- 3-phase 3-wire
- ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 173 to 480 VAC (L-L) ・MP-FEC50M/MP-FEC100M in use: 173 to 240 VAC (L-L)
- 3-phase 4-wire
- ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 277 VAC (L-N), 173 to 480 VAC (L-L) ・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N), 173 to 415 VAC (L-L)
- Apparent energy
- ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: ±0.5% of RD (5% ≤ In ≤ 120%), ±1.0% of RD (1% ≤ In < 5%) *2 *3 ・MP-FEC50M/MP-FEC100M in use: ±1.0% of RD (5% ≤ In ≤ 120%) *3 *4
- Reactive energy
- ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: Compliant with IEC 62053-23 §7.9 table 3 class 2 *2 *3 Reactive power factor 1: ±2.0% of RD (5% ≤ In ≤ 120%), ±2.5% of RD (1% ≤ In < 5%) Reactive power factor 0.5 inductive or capacitive: ±2.0% of RD (10% ≤ In ≤ 120%), ±2.5% of RD (5% ≤ In < 10%) Reactive power factor 0.25 inductive or capacitive: ±2.5% of RD (10% ≤ In ≤ 120%) ・MP-FEC50M/MP-FEC100M in use: ±2.0% of RD (5% ≤ In ≤ 120%) *3
- Power factor (PF)
- -1.00 to 1.00, display resolution 0.01
- Withstand voltage
- Across all terminals and housing: 2500 VAC for 1 minute Across voltage measurement terminal and communication terminal: 2500 VAC for 1 minute Across CT input terminal and communication terminal (When using a specialized CT): 2500 V for 1 minute
- Current consumption
- 36 mA
- Effect of harmonics
- ±0.5% of RD *3 *6
- Insulation resistance
- Across all terminals and housing: 20 MΩ min. (500 VDC) Across voltage measurement term
- Rated input frequency
- 50/60 Hz
- Effect of ambient temperature
- ±0.03%/K *3 *5
- Measurement accuracy / Voltage
- ±0.5% of RD (within rated input voltage) *3
- Number of measurement circuits
- 1 (up to 2 circuits with the 1-phase 2-wire setting *1 )
- Input voltage fluctuation range
- −15% to +15% of the rated input voltage
- Over current withstand capability
- 1.2 times the primary-side rated current (can be applied consecutively), 10 times the primary-side rated current (for 1 second or less)
- Maximum permissible voltage to earth
- ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 480 VAC to earth ・MP-FEC50M/MP-FEC100M in use: 240 VAC to earth
- Active power/reactive power/apparent power
- -8942.400 to +8942.400 [kW/kvar/kVA], display resolution 0.001 [kW/kvar/kVA]
- Active energy/reactive energy/apparent energy
- 0.000 to 999999.999 [kWh/kvarh/kVAh], display resolution 0.001 [kWh/kvarh/kVAh]
- Rated input voltage (direct input) / 1-phase 2-wire
- ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 277 VAC (L-N) ・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N)
- Measurement specifications / Electrical service type
- 1-phase 2-wire, 1-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire (switchable)
- Input specifications / Primary-side rated current, In
- When using specialized CT MP-FEC100: 100 A Or, general CT (secondary-side rated input current 1 A) *2 When using specialized CT MP-FEC250: 250 A Or, general CT (secondary-side rated input current 1 A) *2 When using specialized CT MP-FEC600: 600 A Or, general CT (secondary-side rated input current 1 A) *2 When using specialized CT MP-FEC50M: 50 A When using specialized CT MP-FEC100M: 100 A
- Displayable range/ Display resolution (Main Unit) / Voltage
- Display resolution 0.1 [V]
Compatibility Information
Match MP-FEA1 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing MP-FEA1.
Maintenance Tips
Store MP-FEA1 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. MP-FEA1 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
MP-FEA1 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match MP-FEA1 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114