Product Description

KEYENCE MP-FEA1 Product overview The KEYENCE MP-FEA1 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - 1-phase 3-wire: ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 240 VAC (L-N), 200 to 480 VAC (L-L) ・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N), 200 to 480 VAC (L-L) - 3-phase 3-wire: ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 173 to 480 VAC (L-L) ・MP-FEC50M/MP-FEC100M in use: 173 to 240 VAC (L-L) - 3-phase 4-wire: ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 277 VAC (L-N), 173 to 480 VAC (L-L) ・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N), 173 to 415 VAC (L-L) - Active energy: ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: Compliant with IEC 62053-22 §7.9 table 3 class 0.5 *2 *3 Power factor 1: ±0.5% of RD (5% ≤ In ≤ 120%), ±1.0% of RD (1% ≤ In < 5%) Power factor 0.5 inductive: ±0.6% of RD (10% ≤ In ≤ 120%), ±1.0% of RD (2% ≤ In < 10%) Power factor 0.8 capacitive: ±0.6% of RD (10% ≤ In ≤ 120%), ±1.0% of RD (2% ≤ In < 10%) ・MP-FEC50M/MP-FEC100M in use: ±1.0% of RD (1% ≤ In ≤ 120%) *3 - Active energy/reactive energy/apparent energy: 0.000 to 999999.999 [kWh/kvarh/kVAh], display resolution 0.001 [kWh/kvarh/kVAh] - Active power/reactive power/apparent power: -8942.400 to +8942.400 [kW/kvar/kVA], display resolution 0.001 [kW/kvar/kVA] - Apparent energy: ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: ±0.5% of RD (5% ≤ In ≤ 120%), ±1.0% of RD (1% ≤ In < 5%) *2 *3 ・MP-FEC50M/MP-FEC100M in use: ±1.0% of RD (5% ≤ In ≤ 120%) *3 *4 - Current: Display resolution 0.001 [A] - Current consumption: 36 mA - Displayable range/ Display resolution (Main Unit) / Voltage: Display resolution 0.1 [V] - Effect of ambient temperature: ±0.03%/K *3 *5 - Effect of harmonics: ±0.5% of RD *3 *6 - Frequency: 0.0 to 90.0 [Hz], display resolution 0.1 [Hz] - Input specifications / Primary-side rated current, In: When using specialized CT MP-FEC100: 100 A Or, general CT (secondary-side rated input current 1 A) *2 When using specialized CT MP-FEC250: 250 A Or, general CT (secondary-side rated input current 1 A) *2 When using specialized CT MP-FEC600: 600 A Or, general CT (secondary-side rated input current 1 A) *2 When using specialized CT MP-FEC50M: 50 A When using specialized CT MP-FEC100M: 100 A - Input voltage fluctuation range: −15% to +15% of the rated input voltage - Insulation resistance: Across all terminals and housing: 20 MΩ min. (500 VDC) Across voltage measurement term - Maximum permissible voltage to earth: ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 480 VAC to earth ・MP-FEC50M/MP-FEC100M in use: 240 VAC to earth - Measurement accuracy / Voltage: ±0.5% of RD (within rated input voltage) *3 - Measurement specifications / Electrical service type: 1-phase 2-wire, 1-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire (switchable) - Number of measurement circuits: 1 (up to 2 circuits with the 1-phase 2-wire setting *1 ) - Over current withstand capability: 1.2 times the primary-side rated current (can be applied consecutively), 10 times the primary-side rated current (for 1 second or less) - Power: ±0.1 [Hz] *3 - Power factor (PF): -1.00 to 1.00, display resolution 0.01 - Rated input frequency: 50/60 Hz - Rated input voltage (direct input) / 1-phase 2-wire: ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 277 VAC (L-N) ・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N) - Reactive energy: ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: Compliant with IEC 62053-23 §7.9 table 3 class 2 *2 *3 Reactive power factor 1: ±2.0% of RD (5% ≤ In ≤ 120%), ±2.5% of RD (1% ≤ In < 5%) Reactive power factor 0.5 inductive or capacitive: ±2.0% of RD (10% ≤ In ≤ 120%), ±2.5% of RD (5% ≤ In < 10%) Reactive power factor 0.25 inductive or capacitive: ±2.5% of RD (10% ≤ In ≤ 120%) ・MP-FEC50M/MP-FEC100M in use: ±2.0% of RD (5% ≤ In ≤ 120%) *3 - Withstand voltage: Across all terminals and housing: 2500 VAC for 1 minute Across voltage measurement terminal and communication terminal: 2500 VAC for 1 minute Across CT input terminal and communication terminal (When using a specialized CT): 2500 V for 1 minute Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number MP-FEA1 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
MP-FEA1
Brand
KEYENCE
Part Number
MP-FEA1
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Power
±0.1 [Hz] *3
Current
Display resolution 0.001 [A]
Frequency
0.0 to 90.0 [Hz], display resolution 0.1 [Hz]
Packaging
New surplus, never used
Active energy
・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: Compliant with IEC 62053-22 §7.9 table 3 class 0.5 *2 *3 Power factor 1: ±0.5% of RD (5% ≤ In ≤ 120%), ±1.0% of RD (1% ≤ In < 5%) Power factor 0.5 inductive: ±0.6% of RD (10% ≤ In ≤ 120%), ±1.0% of RD (2% ≤ In < 10%) Power factor 0.8 capacitive: ±0.6% of RD (10% ≤ In ≤ 120%), ±1.0% of RD (2% ≤ In < 10%) ・MP-FEC50M/MP-FEC100M in use: ±1.0% of RD (1% ≤ In ≤ 120%) *3
1-phase 3-wire
・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 240 VAC (L-N), 200 to 480 VAC (L-L) ・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N), 200 to 480 VAC (L-L)
3-phase 3-wire
・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 173 to 480 VAC (L-L) ・MP-FEC50M/MP-FEC100M in use: 173 to 240 VAC (L-L)
3-phase 4-wire
・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 277 VAC (L-N), 173 to 480 VAC (L-L) ・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N), 173 to 415 VAC (L-L)
Apparent energy
・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: ±0.5% of RD (5% ≤ In ≤ 120%), ±1.0% of RD (1% ≤ In < 5%) *2 *3 ・MP-FEC50M/MP-FEC100M in use: ±1.0% of RD (5% ≤ In ≤ 120%) *3 *4
Reactive energy
・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: Compliant with IEC 62053-23 §7.9 table 3 class 2 *2 *3 Reactive power factor 1: ±2.0% of RD (5% ≤ In ≤ 120%), ±2.5% of RD (1% ≤ In < 5%) Reactive power factor 0.5 inductive or capacitive: ±2.0% of RD (10% ≤ In ≤ 120%), ±2.5% of RD (5% ≤ In < 10%) Reactive power factor 0.25 inductive or capacitive: ±2.5% of RD (10% ≤ In ≤ 120%) ・MP-FEC50M/MP-FEC100M in use: ±2.0% of RD (5% ≤ In ≤ 120%) *3
Power factor (PF)
-1.00 to 1.00, display resolution 0.01
Withstand voltage
Across all terminals and housing: 2500 VAC for 1 minute Across voltage measurement terminal and communication terminal: 2500 VAC for 1 minute Across CT input terminal and communication terminal (When using a specialized CT): 2500 V for 1 minute
Current consumption
36 mA
Effect of harmonics
±0.5% of RD *3 *6
Insulation resistance
Across all terminals and housing: 20 MΩ min. (500 VDC) Across voltage measurement term
Rated input frequency
50/60 Hz
Effect of ambient temperature
±0.03%/K *3 *5
Measurement accuracy / Voltage
±0.5% of RD (within rated input voltage) *3
Number of measurement circuits
1 (up to 2 circuits with the 1-phase 2-wire setting *1 )
Input voltage fluctuation range
−15% to +15% of the rated input voltage
Over current withstand capability
1.2 times the primary-side rated current (can be applied consecutively), 10 times the primary-side rated current (for 1 second or less)
Maximum permissible voltage to earth
・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 480 VAC to earth ・MP-FEC50M/MP-FEC100M in use: 240 VAC to earth
Active power/reactive power/apparent power
-8942.400 to +8942.400 [kW/kvar/kVA], display resolution 0.001 [kW/kvar/kVA]
Active energy/reactive energy/apparent energy
0.000 to 999999.999 [kWh/kvarh/kVAh], display resolution 0.001 [kWh/kvarh/kVAh]
Rated input voltage (direct input) / 1-phase 2-wire
・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 277 VAC (L-N) ・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N)
Measurement specifications / Electrical service type
1-phase 2-wire, 1-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire (switchable)
Input specifications / Primary-side rated current, In
When using specialized CT MP-FEC100: 100 A Or, general CT (secondary-side rated input current 1 A) *2 When using specialized CT MP-FEC250: 250 A Or, general CT (secondary-side rated input current 1 A) *2 When using specialized CT MP-FEC600: 600 A Or, general CT (secondary-side rated input current 1 A) *2 When using specialized CT MP-FEC50M: 50 A When using specialized CT MP-FEC100M: 100 A
Displayable range/ Display resolution (Main Unit) / Voltage
Display resolution 0.1 [V]

Compatibility Information

Match MP-FEA1 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing MP-FEA1.

Maintenance Tips

Store MP-FEA1 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114