+86 13348028050
METSEHDPM6S480VC Schneider Electric METSEHDPM6S480VC - Front View | Vcocnc FANUC Parts

Schneider Electric METSEHDPM6S480VC

Product information

$2,747.84 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: METSEHDPM6S480VC

Alternate: METSEHDPM6S480VC

Brand
Schneider Electric
Part No.
METSEHDPM6S480VC
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric METSEHDPM6S480VC Product overview The Schneider Electric METSEHDPM6S480VC is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Communication of data: Power quality Reading of measurements Percentage of load - Communication port protocol: TCP/IP Modbus SNMP BACnet - Communication port support: 2 RJ45 ETHERNET RS485 screw block terminal I/O bus RJ45 - Device short name: HDPM6000 - Energy management: Asset management Measurement Cost management - Measurement accuracy: +/- 1 % - Measurement category: Category III - Measurement voltage: 120…480 V AC 50/60 Hz - Memory capacity: 8 GB - Network Frequency: 60 Hz 50 Hz - Noise level: 0…65 dB - Poles description: 2P + E 3P + E 3P + N + E - Power quality analysis: waveform capture total harmonic distortion - Product or Component Type: Base unit - Range: PowerLogic - Sampling rate: 128 samples/cycle - Type of measurement: Current per channel Current all channels Active energy per channel Active energy all channels Active power per channel Active power all channels Apparent power per channel Apparent power all channels Reactive power per channel Reactive power all channels Frequency Power factor per channel Power factor average Harmonic distorsion (I THD & U THD) Harmonics meter Active energy total Active power total Apparent power total Apparent power demand per channel Apparent power demand all channels Active power demand per channel Active power demand all channels - Web services: Web page Controller configuration Viewing of captured waveform Real time viewing of data - [Us] rated supply voltage: 24 V DC - current transformer input: External CT - product name: PowerLogic HDPM6000 Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number METSEHDPM6S480VC with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
METSEHDPM6S480VC
Brand
Schneider Electric
Part Number
METSEHDPM6S480VC
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
PowerLogic
Packaging
New surplus, never used
Noise level
0…65 dB
Web services
Web page Controller configuration Viewing of captured waveform Real time viewing of data
product name
PowerLogic HDPM6000
Sampling rate
128 samples/cycle
Characteristic
Value(s)
Memory capacity
8 GB
Device short name
HDPM6000
Energy management
Asset management Measurement Cost management
Network Frequency
60 Hz 50 Hz
Poles description
2P + E 3P + E 3P + N + E
Measurement voltage
120…480 V AC 50/60 Hz
Type of measurement
Current per channel Current all channels Active energy per channel Active energy all channels Active power per channel Active power all channels Apparent power per channel Apparent power all channels Reactive power per channel Reactive power all channels Frequency Power factor per channel Power factor average Harmonic distorsion (I THD & U THD) Harmonics meter Active energy total Active power total Apparent power total Apparent power demand per channel Apparent power demand all channels Active power demand per channel Active power demand all channels
Measurement accuracy
+/- 1 %
Measurement category
Category III
Communication of data
Power quality Reading of measurements Percentage of load
Power quality analysis
waveform capture total harmonic distortion
Product or Component Type
Base unit
[Us] rated supply voltage
24 V DC
current transformer input
External CT
Communication port support
2 RJ45 ETHERNET RS485 screw block terminal I/O bus RJ45
Communication port protocol
TCP/IP Modbus SNMP BACnet

Compatibility Information

Match METSEHDPM6S480VC against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing METSEHDPM6S480VC.

Maintenance Tips

Store METSEHDPM6S480VC dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options