+86 13348028050
MD-U2010 KEYENCE MD-U2010 - Front View | Vcocnc FANUC Parts

KEYENCE MD-U2010

Product information

SKU: MD-U2010

Alternate: MDU2010

Brand
KEYENCE
Part No.
MD-U2010
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE MD-U2010 Product overview The KEYENCE MD-U2010 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - 2D code: QR Code/Micro QR Code/DataMatrix (ECC200/GS1 DataMatrix/DMRE) - Ambient temperature: 0 to 40°C 32 to 104°F - Ambient temperature for transport/storage: Max. 85% RH (no condensation) - Appearance: Plane, 3D shapes (slope, cylinder, cone, sphere, 3DCAD (STL)) *4 - Autofocus: MD-AD-ZT - Barcode: CODE39/ITF/2of5/NW7 (CODABAR)/JAN/CODE128/EAN/UPC-A/UPC-E/CODE93/GS1 DataBar - Built-In Camera / Image sensor: CMOS image sensor (2.3 megapixels) - Built-in 2D code reader: MD-AD-2DR/MD-AD-2DRA (corresponding standard ISO/IEC TR 29158 (AIM DPM-1-2006)) - Built-in camera alignment: MD-AD-XYT - Built-in light source: High-intensity green LED - Built-in power meter: Thermopile - Character type / Font: Original Font/User Font/TrueType Font/OpenType Font *3 - Compatible regulations: EU Directives (EMC Directive, Low Voltage Directive, RoHS Directive) / EN Standards (EN61010-1, EN60825-1, EN62471, EN55011, EN61000-6-2, EN63000) / CSA Standards and UL Standards (CAN/CSA C22.2 No. 61010-1, UL61010-1) / North American Standards (FCC Part 15B, ICES-001 Class A) / China RoHS/UKCA - Distance measurement laser: Semiconductor laser wavelength: 683 nm output: 5.0 mW class 3R laser product (IEC/EN60825-1, JIS C6802, FDA (CDRH) Part 1040.10) *1 - Enclosure rating: IP64 (head part) - Environmental resistance / Ambient temperature for transport/storage: -10 to 60°C 14 to 140°F (no freezing) - Guide laser: Semiconductor laser wavelength: 655 nm output: 1.0 mW class 2 laser product (IEC/EN60825-1, JIS C6802, FDA (CDRH) Part 1040.10) *1 - Handheld console: MC-P1 - Input / Output: Terminal block input and output/MIL connector input and output/Laser safety module control input and output *5 - Interface: RS-232C/USB2.0/Ethernet (100BASE-TX) *6 - Laser class / Marking laser: YVO 4 laser wavelength: 355 nm class 4 laser product (IEC/EN60825-1, JIS C6802, FDA (CDRH) Part 1040.10) *1 - Laser safety module: MD-C2BU - Logging function: Internal operation/terminal block/communication/error/operating information/built-in camera image - Logo image: DXF/BMP/JPEG/PNG/TIFF - Marking area: 125 × 125 × 42 mm 4.92"×4.92"×1.65" - Marking laser / Output: 3 W/40 kHz (output at contact point: 2.5 W) - Marking method: XYZ 3-axis simultaneous scanning method - Marking method / XY scanner: Digital galvo scanner - Marking unit cable length: 4.6 ± 0.1 m 15.1' ± 0.3' - No. equipped: 2 (full-view camera/coaxial camera) - Optional models / 3D marking: MD-AD-3D - PC software: MB-PH1 (Marking Builder Plus/Marking Diagnostic Tool) *2 - Q-switch frequency: CW (continuous oscillation), 40 to 400 kHz - Standard working distance (±variation width): 189 mm 7.44" (± 21 mm ± 0.83" ) - Type: 2.5 W type Standard area type Head - Weight: Controller: 9.7 kg 21.38 lb Head: 21.7 kg 47.84 lb Control cable: 2.5 kg 5.51 lb Console: 2.0 kg 4.41 lb - Work state: Stationary/moving (constant velocity, encoder/rotary marking) - Z scanner: Linear motor Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number MD-U2010 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
MD-U2010
Brand
KEYENCE
Part Number
MD-U2010
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
2.5 W type Standard area type Head
Weight
Controller: 9.7 kg 21.38 lb Head: 21.7 kg 47.84 lb Control cable: 2.5 kg 5.51 lb Console: 2.0 kg 4.41 lb
2D code
QR Code/Micro QR Code/DataMatrix (ECC200/GS1 DataMatrix/DMRE)
Barcode
CODE39/ITF/2of5/NW7 (CODABAR)/JAN/CODE128/EAN/UPC-A/UPC-E/CODE93/GS1 DataBar
Autofocus
MD-AD-ZT
Interface
RS-232C/USB2.0/Ethernet (100BASE-TX) *6
Z scanner
Linear motor
Appearance
Plane, 3D shapes (slope, cylinder, cone, sphere, 3DCAD (STL)) *4
Logo image
DXF/BMP/JPEG/PNG/TIFF
Work state
Stationary/moving (constant velocity, encoder/rotary marking)
Guide laser
Semiconductor laser wavelength: 655 nm output: 1.0 mW class 2 laser product (IEC/EN60825-1, JIS C6802, FDA (CDRH) Part 1040.10) *1
PC software
MB-PH1 (Marking Builder Plus/Marking Diagnostic Tool) *2
Marking area
125 × 125 × 42 mm 4.92"×4.92"×1.65"
No. equipped
2 (full-view camera/coaxial camera)
Input / Output
Terminal block input and output/MIL connector input and output/Laser safety module control input and output *5
Marking method
XYZ 3-axis simultaneous scanning method
Enclosure rating
IP64 (head part)
Handheld console
MC-P1
Logging function
Internal operation/terminal block/communication/error/operating information/built-in camera image
Q-switch frequency
CW (continuous oscillation), 40 to 400 kHz
Ambient temperature
0 to 40°C 32 to 104°F
Laser safety module
MD-C2BU
Built-in power meter
Thermopile
Built-in light source
High-intensity green LED
Character type / Font
Original Font/User Font/TrueType Font/OpenType Font *3
Compatible regulations
EU Directives (EMC Directive, Low Voltage Directive, RoHS Directive) / EN Standards (EN61010-1, EN60825-1, EN62471, EN55011, EN61000-6-2, EN63000) / CSA Standards and UL Standards (CAN/CSA C22.2 No. 61010-1, UL61010-1) / North American Standards (FCC Part 15B, ICES-001 Class A) / China RoHS/UKCA
Marking laser / Output
3 W/40 kHz (output at contact point: 2.5 W)
Built-in 2D code reader
MD-AD-2DR/MD-AD-2DRA (corresponding standard ISO/IEC TR 29158 (AIM DPM-1-2006))
Built-in camera alignment
MD-AD-XYT
Marking unit cable length
4.6 ± 0.1 m 15.1' ± 0.3'
Distance measurement laser
Semiconductor laser wavelength: 683 nm output: 5.0 mW class 3R laser product (IEC/EN60825-1, JIS C6802, FDA (CDRH) Part 1040.10) *1
Laser class / Marking laser
YVO 4 laser wavelength: 355 nm class 4 laser product (IEC/EN60825-1, JIS C6802, FDA (CDRH) Part 1040.10) *1
Marking method / XY scanner
Digital galvo scanner
Optional models / 3D marking
MD-AD-3D
Built-In Camera / Image sensor
CMOS image sensor (2.3 megapixels)
Ambient temperature for transport/storage
Max. 85% RH (no condensation)
Standard working distance (±variation width)
189 mm 7.44" (± 21 mm ± 0.83" )
Environmental resistance / Ambient temperature for transport/storage
-10 to 60°C 14 to 140°F (no freezing)

Compatibility Information

Match MD-U2010 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing MD-U2010.

Maintenance Tips

Store MD-U2010 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114