+86 13348028050
M9F23416 Schneider Electric M9F23416 - Front View | Vcocnc FANUC Parts

Schneider Electric M9F23416

Product information

SKU: M9F23416

Alternate: M9F23416

Brand
Schneider Electric
Part No.
M9F23416
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric M9F23416 Product overview The Schneider Electric M9F23416 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - 9 mm pitches: 8 - Breaking capacity: 14 kA AIR 240 V AC UL 1077 14 kA AIR 240 V AC CSA C22.2 No 235 10 kA AIR 480Y/277 V AC UL 1077 10 kA AIR 480Y/277 V AC CSA C22.2 No 235 6 kA Icu 440 V AC EN/IEC 60947-2 10 kA Icu 415 V AC EN/IEC 60947-2 20 kA Icu 240 V AC EN/IEC 60947-2 6 kA Icu 440 V AC GB 14048.2 10 kA Icu 415 V AC GB 14048.2 20 kA Icu 240 V AC GB 14048.2 - Characteristic: Value(s) - Connections - terminals: Tunnel type terminal top or bottom) 0.002…0.04 in² (1…25 mm²) AWG 18...AWG 8) - rigid Tunnel type terminal top or bottom) 0.002…0.02 in² (1…16 mm²) AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal top or bottom) 0.002…0.02 in² (1…16 mm²) AWG 18...AWG 8) - flexible - Contact position indicator: Yes - Control Type: Toggle - Curve code: D - Depth: 2.8 in (72 mm) - Device Application: Distribution - Device short name: C60SP - Earth-leakage protection: Without - Electrical durability: 10000 cycles - Height: 3.2 in (81 mm) - Line Rated Current: 16 A 77 °F (25 °C) EN/IEC 60947-2 - Local signalling: ON/OFF indication - Magnetic tripping limit: 12 x In +/- 20 % AC - Mechanical durability: 20000 cycles - Mounting Mode: Clip-on - Mounting Support: DIN rail - Network type: AC - Number of protected poles: 4 - Poles description: 4P - Product certifications: IEC CCC UR CSA - Product or Component Type: Miniature circuit-breaker - Provision for padlocking: Padlockable - Range: Multi9 - Standards: EN/IEC 60947-2 GB 14048.2 UL 1077 CSA C22.2 No 235 - Suitability for isolation: Yes EN/IEC 60947-2 - Tightening torque: 22.1 lbf.in (2.5 N.m) top or bottom - Trip unit technology: Thermal-magnetic - Width: 2.8 in (72 mm) - Wire stripping length: 0.6 in (14 mm) for top or bottom connection - [Ics] rated service breaking capacity: 4.5 kA 75 % EN/IEC 60947-2 - 440 V AC 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC 15 kA 75 % EN/IEC 60947-2 - 240 V AC 4.5 kA 75 % GB 14048.2 - 440 V AC 7.5 kA 75 % GB 14048.2 - 415 V AC 15 kA 75 % GB 14048.2 - 240 V AC - [Ue] rated operational voltage: 240 V AC 50/60 Hz 415 V AC 50/60 Hz 440 V AC 50/60 Hz - [Ui] rated insulation voltage: 500 V AC EN/IEC 60947-2 - [Uimp] rated impulse withstand voltage: 6 kVEN/IEC 60947-2 - color: Gray - product name: Multi9 C60 Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number M9F23416 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
M9F23416
Brand
Schneider Electric
Part Number
M9F23416
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Depth
2.8 in (72 mm)
Range
Multi9
Width
2.8 in (72 mm)
color
Gray
Height
3.2 in (81 mm)
Standards
EN/IEC 60947-2 GB 14048.2 UL 1077 CSA C22.2 No 235
Curve code
D
9 mm pitches
8
Control Type
Toggle
Network type
AC
product name
Multi9 C60
Mounting Mode
Clip-on
Characteristic
Value(s)
Local signalling
ON/OFF indication
Mounting Support
DIN rail
Breaking capacity
14 kA AIR 240 V AC UL 1077 14 kA AIR 240 V AC CSA C22.2 No 235 10 kA AIR 480Y/277 V AC UL 1077 10 kA AIR 480Y/277 V AC CSA C22.2 No 235 6 kA Icu 440 V AC EN/IEC 60947-2 10 kA Icu 415 V AC EN/IEC 60947-2 20 kA Icu 240 V AC EN/IEC 60947-2 6 kA Icu 440 V AC GB 14048.2 10 kA Icu 415 V AC GB 14048.2 20 kA Icu 240 V AC GB 14048.2
Device short name
C60SP
Poles description
4P
Tightening torque
22.1 lbf.in (2.5 N.m) top or bottom
Device Application
Distribution
Line Rated Current
16 A 77 °F (25 °C) EN/IEC 60947-2
Trip unit technology
Thermal-magnetic
Electrical durability
10000 cycles
Mechanical durability
20000 cycles
Wire stripping length
0.6 in (14 mm) for top or bottom connection
Product certifications
IEC CCC UR CSA
Connections - terminals
Tunnel type terminal top or bottom) 0.002…0.04 in² (1…25 mm²) AWG 18...AWG 8) - rigid Tunnel type terminal top or bottom) 0.002…0.02 in² (1…16 mm²) AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal top or bottom) 0.002…0.02 in² (1…16 mm²) AWG 18...AWG 8) - flexible
Magnetic tripping limit
12 x In +/- 20 % AC
Earth-leakage protection
Without
Provision for padlocking
Padlockable
Number of protected poles
4
Product or Component Type
Miniature circuit-breaker
Suitability for isolation
Yes EN/IEC 60947-2
Contact position indicator
Yes
[Ui] rated insulation voltage
500 V AC EN/IEC 60947-2
[Ue] rated operational voltage
240 V AC 50/60 Hz 415 V AC 50/60 Hz 440 V AC 50/60 Hz
[Ics] rated service breaking capacity
4.5 kA 75 % EN/IEC 60947-2 - 440 V AC 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC 15 kA 75 % EN/IEC 60947-2 - 240 V AC 4.5 kA 75 % GB 14048.2 - 440 V AC 7.5 kA 75 % GB 14048.2 - 415 V AC 15 kA 75 % GB 14048.2 - 240 V AC
[Uimp] rated impulse withstand voltage
6 kVEN/IEC 60947-2

Compatibility Information

Match M9F23416 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing M9F23416.

Maintenance Tips

Store M9F23416 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options