+86 13348028050
LV480508 Schneider Electric LV480508 - Front View | Vcocnc FANUC Parts

Schneider Electric LV480508

Product information

SKU: LV480508

Alternate: LV480508

Brand
Schneider Electric
Part No.
LV480508
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LV480508 Product overview The Schneider Electric LV480508 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Contact operation: Double-break - Contact position indicator: Yes - Device application: Protection - Device short name: INFD400 - Fuse size: NH0 NH2 NH1 - Fuse type: DIN - Maximum power: AC-23: 132 kW at 220/240 V AC 50/60 Hz AC-23: 220 kW at 380/400 V AC 50/60 Hz AC-23: 230 kW at 415 V AC 50/60 Hz AC-23: 280 kW at 500/525 V AC 50/60 Hz AC-23: 400 kW at 660/690 V AC 50/60 Hz - Mounting mode: Fixed - Mounting support: Mounting plate - Network frequency: 50/60 Hz - Network type: AC DC - Poles description: 4P - Product or component type: Switch-disconnector-fuse - Protected poles description: 4f - Range: FuPact - Range of product: INF200...800 - Rated duty: Uninterrupted - Rotary handle mounting location: Front - Suitability for isolation: Yes conforming to IEC 60947-1 - [Ie] rated operational current: AC-22A: 400 A at 220/240 V AC 50/60 Hz AC-22A: 400 A at 380/415 V AC 50/60 Hz AC-22A: 400 A at 440/480 V AC 50/60 Hz AC-22A: 400 A at 500/525 V AC 50/60 Hz AC-22A: 400 A at 660/690 V AC 50/60 Hz AC-23A: 400 A at 220/240 V AC 50/60 Hz AC-23A: 400 A at 380/415 V AC 50/60 Hz AC-23A: 400 A at 440/480 V AC 50/60 Hz AC-23A: 400 A at 500/525 V AC 50/60 Hz AC-23A: 400 A at 660/690 V AC 50/60 Hz DC-22A: 400 A at 125 V DC (2 poles in series) DC-23A: 400 A at 125 V DC (2 poles in series) AC-22A: 400 A at 480 V AC 50/60 Hz conforming to NEMA AC-23A: 400 A at 480 V AC 50/60 Hz conforming to NEMA DC-22A: 400 A at 250 V DC (3 poles in series) DC-23A: 400 A at 250 V DC (3 poles in series) DC-22A: 400 A at 500 V DC (4 poles in series) DC-22A: 400 A at 750 V DC (4 poles in series) DC-23A: 400 A at 500 V DC (4 poles in series) DC-23A: 400 A at 750 V DC (4 poles in series) - [Im] rated making and breaking capacity: Icm 220 kA at 500 V conforming to DIN (with fuse) Icn 100 kA at 500 V conforming to DIN (with fuse) Icm 176 kA at 415 V conforming to DIN (with fuse) Icm 176 kA at 690 V conforming to DIN (with fuse) Icn 80 kA at 415 V conforming to DIN (with fuse) Icn 80 kA at 690 V conforming to DIN (with fuse) Icm 48 kA at 690 V (without fuse) Icm 59 kA at 415 V (without fuse) Icm 63.5 kA at 500 V (without fuse) - [Ith] conventional free air thermal current: 400 A ( 40 °C ) power dissipation per fuse: 45 W vertical 283 A ( 70 °C ) horizontal 283 A ( 70 °C ) vertical 302 A ( 65 °C ) horizontal 302 A ( 65 °C ) vertical 321 A ( 60 °C ) horizontal 321 A ( 60 °C ) vertical 338 A ( 55 °C ) horizontal 338 A ( 55 °C ) vertical 355 A ( 50 °C ) horizontal 355 A ( 50 °C ) vertical 370 A ( 45 °C ) horizontal 370 A ( 45 °C ) vertical 385 A ( 40 °C ) horizontal 400 A ( 35 °C ) horizontal - [Ithe] conventional enclosed thermal current: 360 A at 40 °C, Power dissipation per fuse: 37 W (610 mm x 508 mm x 254 mm) 400 A at 40 °C, Power dissipation per fuse: 30 W (610 mm x 508 mm x 254 mm) - [Ue] rated operational voltage: 690 V AC 50/60 Hz 1000 V AC 50/60 Hz AC-20 1000 V DC DC-20 750 V DC - [Ui] rated insulation voltage: 1000 V AC 50/60 Hz 1000 V DC - [Uimp] rated impulse withstand voltage: 12 kV - control type: Operating shaft (without handle) - product name: Fupact INF Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LV480508 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LV480508
Brand
Schneider Electric
Part Number
LV480508
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
FuPact
Fuse size
NH0 NH2 NH1
Fuse type
DIN
Rated duty
Uninterrupted
Network type
AC DC
control type
Operating shaft (without handle)
product name
Fupact INF
Maximum power
AC-23: 132 kW at 220/240 V AC 50/60 Hz AC-23: 220 kW at 380/400 V AC 50/60 Hz AC-23: 230 kW at 415 V AC 50/60 Hz AC-23: 280 kW at 500/525 V AC 50/60 Hz AC-23: 400 kW at 660/690 V AC 50/60 Hz
Mounting mode
Fixed
Characteristic
Value(s)
Mounting support
Mounting plate
Range of product
INF200...800
Contact operation
Double-break
Device short name
INFD400
Network frequency
50/60 Hz
Poles description
4P
Device application
Protection
Product or component type
Switch-disconnector-fuse
Suitability for isolation
Yes conforming to IEC 60947-1
Contact position indicator
Yes
Protected poles description
4f
[Ui] rated insulation voltage
1000 V AC 50/60 Hz 1000 V DC
[Ie] rated operational current
AC-22A: 400 A at 220/240 V AC 50/60 Hz AC-22A: 400 A at 380/415 V AC 50/60 Hz AC-22A: 400 A at 440/480 V AC 50/60 Hz AC-22A: 400 A at 500/525 V AC 50/60 Hz AC-22A: 400 A at 660/690 V AC 50/60 Hz AC-23A: 400 A at 220/240 V AC 50/60 Hz AC-23A: 400 A at 380/415 V AC 50/60 Hz AC-23A: 400 A at 440/480 V AC 50/60 Hz AC-23A: 400 A at 500/525 V AC 50/60 Hz AC-23A: 400 A at 660/690 V AC 50/60 Hz DC-22A: 400 A at 125 V DC (2 poles in series) DC-23A: 400 A at 125 V DC (2 poles in series) AC-22A: 400 A at 480 V AC 50/60 Hz conforming to NEMA AC-23A: 400 A at 480 V AC 50/60 Hz conforming to NEMA DC-22A: 400 A at 250 V DC (3 poles in series) DC-23A: 400 A at 250 V DC (3 poles in series) DC-22A: 400 A at 500 V DC (4 poles in series) DC-22A: 400 A at 750 V DC (4 poles in series) DC-23A: 400 A at 500 V DC (4 poles in series) DC-23A: 400 A at 750 V DC (4 poles in series)
[Ue] rated operational voltage
690 V AC 50/60 Hz 1000 V AC 50/60 Hz AC-20 1000 V DC DC-20 750 V DC
Rotary handle mounting location
Front
[Uimp] rated impulse withstand voltage
12 kV
[Im] rated making and breaking capacity
Icm 220 kA at 500 V conforming to DIN (with fuse) Icn 100 kA at 500 V conforming to DIN (with fuse) Icm 176 kA at 415 V conforming to DIN (with fuse) Icm 176 kA at 690 V conforming to DIN (with fuse) Icn 80 kA at 415 V conforming to DIN (with fuse) Icn 80 kA at 690 V conforming to DIN (with fuse) Icm 48 kA at 690 V (without fuse) Icm 59 kA at 415 V (without fuse) Icm 63.5 kA at 500 V (without fuse)
[Ith] conventional free air thermal current
400 A ( 40 °C ) power dissipation per fuse: 45 W vertical 283 A ( 70 °C ) horizontal 283 A ( 70 °C ) vertical 302 A ( 65 °C ) horizontal 302 A ( 65 °C ) vertical 321 A ( 60 °C ) horizontal 321 A ( 60 °C ) vertical 338 A ( 55 °C ) horizontal 338 A ( 55 °C ) vertical 355 A ( 50 °C ) horizontal 355 A ( 50 °C ) vertical 370 A ( 45 °C ) horizontal 370 A ( 45 °C ) vertical 385 A ( 40 °C ) horizontal 400 A ( 35 °C ) horizontal
[Ithe] conventional enclosed thermal current
360 A at 40 °C, Power dissipation per fuse: 37 W (610 mm x 508 mm x 254 mm) 400 A at 40 °C, Power dissipation per fuse: 30 W (610 mm x 508 mm x 254 mm)

Compatibility Information

Match LV480508 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LV480508.

Maintenance Tips

Store LV480508 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options