+86 13348028050
LV480504 Schneider Electric LV480504 - Front View | Vcocnc FANUC Parts

Schneider Electric LV480504

Product information

SKU: LV480504

Alternate: LV480504

Brand
Schneider Electric
Part No.
LV480504
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LV480504 Product overview The Schneider Electric LV480504 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Contact operation: Double-break - Contact position indicator: Yes - Device application: Protection - Device short name: INFD250 - Fuse size: NH1 NH0 - Fuse type: DIN - Maximum power: AC-23: 140 kW at 380/400 V AC 50/60 Hz AC-23: 145 kW at 415 V AC 50/60 Hz AC-23: 170 kW at 500/525 V AC 50/60 Hz AC-23: 250 kW at 660/690 V AC 50/60 Hz AC-23: 75 kW at 220/240 V AC 50/60 Hz - Mounting mode: Fixed - Mounting support: Mounting plate - Network frequency: 50/60 Hz - Network type: AC DC - Poles description: 4P - Product or component type: Switch-disconnector-fuse - Protected poles description: 3f - Range: FuPact - Range of product: INF200...800 - Rated duty: Uninterrupted - Rotary handle mounting location: Front - Suitability for isolation: Yes conforming to IEC 60947-1 - [Ie] rated operational current: AC-22A: 250 A at 220/240 V AC 50/60 Hz AC-22A: 250 A at 380/415 V AC 50/60 Hz AC-22A: 250 A at 440/480 V AC 50/60 Hz AC-22A: 250 A at 500/525 V AC 50/60 Hz AC-22A: 250 A at 660/690 V AC 50/60 Hz AC-23A: 250 A at 220/240 V AC 50/60 Hz AC-23A: 250 A at 380/415 V AC 50/60 Hz AC-23A: 250 A at 440/480 V AC 50/60 Hz AC-23A: 250 A at 500/525 V AC 50/60 Hz AC-23A: 250 A at 660/690 V AC 50/60 Hz DC-22A: 250 A at 250 V DC (2 poles in series) DC-22A: 250 A at 500 V DC (3 poles in series) DC-23A: 250 A at 250 V DC (2 poles in series) DC-23A: 250 A at 500 V DC (3 poles in series) AC-22A: 250 A at 480 V AC 50/60 Hz conforming to NEMA AC-23A: 250 A at 480 V AC 50/60 Hz conforming to NEMA DC-22A: 250 A at 125 V DC (1 pole) DC-23A: 250 A at 125 V DC (1 pole) - [Im] rated making and breaking capacity: Icm 220 kA at 500 V conforming to DIN (with fuse) Icn 100 kA at 500 V conforming to DIN (with fuse) Icm 176 kA at 415 V conforming to DIN (with fuse) Icm 176 kA at 690 V conforming to DIN (with fuse) Icm 28 kA at 690 V (without fuse) Icn 80 kA at 415 V conforming to DIN (with fuse) Icn 80 kA at 690 V conforming to DIN (with fuse) Icm 37.5 kA at 500 V (without fuse) Icm 40.5 kA at 415 V (without fuse) - [Ith] conventional free air thermal current: 200 A ( 60 °C ) vertical 250 A ( 40 °C ) power dissipation per fuse: 23 W vertical 177 A ( 70 °C ) horizontal 177 A ( 70 °C ) vertical 189 A ( 65 °C ) horizontal 189 A ( 65 °C ) vertical 200 A ( 60 °C ) horizontal 211 A ( 55 °C ) horizontal 211 A ( 55 °C ) vertical 222 A ( 50 °C ) horizontal 222 A ( 50 °C ) vertical 231 A ( 45 °C ) horizontal 232 A ( 45 °C ) vertical 241 A ( 40 °C ) horizontal 250 A ( 35 °C ) horizontal - [Ithe] conventional enclosed thermal current: 230 A at 40 °C, Power dissipation per fuse: 27 W (800 mm x 400 mm x 330 mm) 250 A at 40 °C, Power dissipation per fuse: 20 W (800 mm x 400 mm x 330 mm) - [Ue] rated operational voltage: 690 V AC 50/60 Hz 1000 V AC 50/60 Hz AC-20 1000 V DC DC-20 750 V DC - [Ui] rated insulation voltage: 1000 V AC 50/60 Hz 1000 V DC - [Uimp] rated impulse withstand voltage: 12 kV - control type: Operating shaft (without handle) - product name: Fupact INF Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LV480504 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LV480504
Brand
Schneider Electric
Part Number
LV480504
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
FuPact
Fuse size
NH1 NH0
Fuse type
DIN
Rated duty
Uninterrupted
Network type
AC DC
control type
Operating shaft (without handle)
product name
Fupact INF
Maximum power
AC-23: 140 kW at 380/400 V AC 50/60 Hz AC-23: 145 kW at 415 V AC 50/60 Hz AC-23: 170 kW at 500/525 V AC 50/60 Hz AC-23: 250 kW at 660/690 V AC 50/60 Hz AC-23: 75 kW at 220/240 V AC 50/60 Hz
Mounting mode
Fixed
Characteristic
Value(s)
Mounting support
Mounting plate
Range of product
INF200...800
Contact operation
Double-break
Device short name
INFD250
Network frequency
50/60 Hz
Poles description
4P
Device application
Protection
Product or component type
Switch-disconnector-fuse
Suitability for isolation
Yes conforming to IEC 60947-1
Contact position indicator
Yes
Protected poles description
3f
[Ui] rated insulation voltage
1000 V AC 50/60 Hz 1000 V DC
[Ie] rated operational current
AC-22A: 250 A at 220/240 V AC 50/60 Hz AC-22A: 250 A at 380/415 V AC 50/60 Hz AC-22A: 250 A at 440/480 V AC 50/60 Hz AC-22A: 250 A at 500/525 V AC 50/60 Hz AC-22A: 250 A at 660/690 V AC 50/60 Hz AC-23A: 250 A at 220/240 V AC 50/60 Hz AC-23A: 250 A at 380/415 V AC 50/60 Hz AC-23A: 250 A at 440/480 V AC 50/60 Hz AC-23A: 250 A at 500/525 V AC 50/60 Hz AC-23A: 250 A at 660/690 V AC 50/60 Hz DC-22A: 250 A at 250 V DC (2 poles in series) DC-22A: 250 A at 500 V DC (3 poles in series) DC-23A: 250 A at 250 V DC (2 poles in series) DC-23A: 250 A at 500 V DC (3 poles in series) AC-22A: 250 A at 480 V AC 50/60 Hz conforming to NEMA AC-23A: 250 A at 480 V AC 50/60 Hz conforming to NEMA DC-22A: 250 A at 125 V DC (1 pole) DC-23A: 250 A at 125 V DC (1 pole)
[Ue] rated operational voltage
690 V AC 50/60 Hz 1000 V AC 50/60 Hz AC-20 1000 V DC DC-20 750 V DC
Rotary handle mounting location
Front
[Uimp] rated impulse withstand voltage
12 kV
[Im] rated making and breaking capacity
Icm 220 kA at 500 V conforming to DIN (with fuse) Icn 100 kA at 500 V conforming to DIN (with fuse) Icm 176 kA at 415 V conforming to DIN (with fuse) Icm 176 kA at 690 V conforming to DIN (with fuse) Icm 28 kA at 690 V (without fuse) Icn 80 kA at 415 V conforming to DIN (with fuse) Icn 80 kA at 690 V conforming to DIN (with fuse) Icm 37.5 kA at 500 V (without fuse) Icm 40.5 kA at 415 V (without fuse)
[Ith] conventional free air thermal current
200 A ( 60 °C ) vertical 250 A ( 40 °C ) power dissipation per fuse: 23 W vertical 177 A ( 70 °C ) horizontal 177 A ( 70 °C ) vertical 189 A ( 65 °C ) horizontal 189 A ( 65 °C ) vertical 200 A ( 60 °C ) horizontal 211 A ( 55 °C ) horizontal 211 A ( 55 °C ) vertical 222 A ( 50 °C ) horizontal 222 A ( 50 °C ) vertical 231 A ( 45 °C ) horizontal 232 A ( 45 °C ) vertical 241 A ( 40 °C ) horizontal 250 A ( 35 °C ) horizontal
[Ithe] conventional enclosed thermal current
230 A at 40 °C, Power dissipation per fuse: 27 W (800 mm x 400 mm x 330 mm) 250 A at 40 °C, Power dissipation per fuse: 20 W (800 mm x 400 mm x 330 mm)

Compatibility Information

Match LV480504 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LV480504.

Maintenance Tips

Store LV480504 dry and dust-free in its packaging until installation.