+86 13348028050
LV438272 Schneider Electric LV438272 - Front View | Vcocnc FANUC Parts

Schneider Electric LV438272

Product information

SKU: LV438272

Alternate: LV438272

Brand
Schneider Electric
Part No.
LV438272
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LV438272 Product overview The Schneider Electric LV438272 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Circuit breaker mounting mode: Fixed - Connection pitch: 45 mm - Depth (D): 110 mm - Device application: Distribution - Device short name: NSX400S DC - Downside connection: Front - Earth-leakage protection: Without - Electrical durability: 1000 cycles at 750 V In 2000 cycles at 750 V In/2 - Height (H): 255 mm - Long-time pick-up adjustment type Ir (thermal protection): Adjustable - Mechanical durability: 5000 cycles - Mounting support: Backplate - Network type: DC - Neutral position: Left - Number of poles: 4P - Number of slots for electrical auxiliaries: 6 slot(s) - Performance level: S 100 kA 500 V DC - Product or component type: Circuit breaker - Product weight: 7.9 kg - Protected poles description: 4t - Protection type: L : for overload protection (thermal) I : for short-circuit protection (magnetic) - Range: ComPact - Range of product: ComPact NSX400...630 DC - Suitability for isolation: Yes conforming to EN/IEC 60947-2 - Trip unit name: TM-DC - Trip unit rating: 400 A at 40 °C - Trip unit technology: Thermal-magnetic - Upside connection: Front - Utilisation category: Category A - Width (W): 185 mm - [Ics] rated service short-circuit breaking capacity: 100 kA at 750 V DC conforming to IEC 60947-2 - [Icu] rated ultimate short-circuit breaking capacity: 100 kA Icu at 250 V DC 1P conforming to IEC 60947-2 100 kA Icu at 500 V DC 2P conforming to IEC 60947-2 100 kA Icu at 750 V DC 3P conforming to IEC 60947-2 100 kA Icu at 750 V DC 4P conforming to IEC 60947-2 - [In] rated current: 400 A at 40 °C - [Ir] long-time protection pick-up adjustment range: 0.7...1 x In - [Ue] rated operational voltage: 750 V DC - [Ui] rated insulation voltage: 750 V DC conforming to IEC 60947-2 - [Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947-2 - control type: Toggle - product name: ComPact NSX DC Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LV438272 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LV438272
Brand
Schneider Electric
Part Number
LV438272
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
ComPact
Depth (D)
110 mm
Width (W)
185 mm
Height (H)
255 mm
Network type
DC
control type
Toggle
product name
ComPact NSX DC
Characteristic
Value(s)
Product weight
7.9 kg
Trip unit name
TM-DC
Number of poles
4P
Protection type
L : for overload protection (thermal) I : for short-circuit protection (magnetic)
Connection pitch
45 mm
Mounting support
Backplate
Neutral position
Left
Range of product
ComPact NSX400...630 DC
Trip unit rating
400 A at 40 °C
Device short name
NSX400S DC
Performance level
S 100 kA 500 V DC
Upside connection
Front
Device application
Distribution
[In] rated current
400 A at 40 °C
Downside connection
Front
Trip unit technology
Thermal-magnetic
Utilisation category
Category A
Electrical durability
1000 cycles at 750 V In 2000 cycles at 750 V In/2
Mechanical durability
5000 cycles
Earth-leakage protection
Without
Product or component type
Circuit breaker
Suitability for isolation
Yes conforming to EN/IEC 60947-2
Protected poles description
4t
Circuit breaker mounting mode
Fixed
[Ui] rated insulation voltage
750 V DC conforming to IEC 60947-2
[Ue] rated operational voltage
750 V DC
[Uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947-2
Number of slots for electrical auxiliaries
6 slot(s)
[Ir] long-time protection pick-up adjustment range
0.7...1 x In
[Ics] rated service short-circuit breaking capacity
100 kA at 750 V DC conforming to IEC 60947-2
[Icu] rated ultimate short-circuit breaking capacity
100 kA Icu at 250 V DC 1P conforming to IEC 60947-2 100 kA Icu at 500 V DC 2P conforming to IEC 60947-2 100 kA Icu at 750 V DC 3P conforming to IEC 60947-2 100 kA Icu at 750 V DC 4P conforming to IEC 60947-2
Long-time pick-up adjustment type Ir (thermal protection)
Adjustable

Compatibility Information

Match LV438272 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LV438272.

Maintenance Tips

Store LV438272 dry and dust-free in its packaging until installation.