+86 13348028050
LV438260 Schneider Electric LV438260 - Front View | Vcocnc FANUC Parts

Schneider Electric LV438260

Product information

$518.63 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: LV438260

Alternate: LV438260

Brand
Schneider Electric
Part No.
LV438260
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LV438260 Product overview The Schneider Electric LV438260 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Circuit breaker mounting mode: Fixed - Connection pitch: 45 mm - Depth (D): 110 mm - Device application: Distribution - Device short name: NSX250F DC - Downside connection: Front - Earth-leakage protection: Without - Electrical durability: 1000 cycles at 750 V In 2000 cycles at 750 V In/2 - Height (H): 255 mm - Long-time pick-up adjustment type Ir (thermal protection): Adjustable - Mechanical durability: 5000 cycles - Mounting support: Backplate - Network type: DC - Neutral position: Left - Number of poles: 4P - Number of slots for electrical auxiliaries: 6 slot(s) - Performance level: F 36 kA 750 V DC - Product or component type: Circuit breaker - Product weight: 7.9 kg - Protected poles description: 4t - Protection type: L : for overload protection (thermal) I : for short-circuit protection (magnetic) - Range: ComPact - Range of product: ComPact NSX400...630 DC - Suitability for isolation: Yes conforming to EN/IEC 60947-2 - Trip unit name: TM-DC - Trip unit rating: 250 A at 40 °C - Trip unit technology: Thermal-magnetic - Upside connection: Front - Utilisation category: Category A - Width (W): 185 mm - [Ics] rated service short-circuit breaking capacity: 36 kA at 750 V DC conforming to IEC 60947-2 - [Icu] rated ultimate short-circuit breaking capacity: 36 kA Icu at 250 V DC 1P conforming to IEC 60947-2 36 kA Icu at 500 V DC 2P conforming to IEC 60947-2 36 kA Icu at 750 V DC 3P conforming to IEC 60947-2 36 kA Icu at 750 V DC 4P conforming to IEC 60947-2 - [In] rated current: 250 A at 40 °C - [Ir] long-time protection pick-up adjustment range: 0.7...1 x In - [Ue] rated operational voltage: 750 V DC - [Ui] rated insulation voltage: 750 V DC conforming to IEC 60947-2 - [Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947-2 - control type: Toggle - product name: ComPact NSX DC Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LV438260 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LV438260
Brand
Schneider Electric
Part Number
LV438260
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
ComPact
Depth (D)
110 mm
Packaging
New surplus, never used
Width (W)
185 mm
Height (H)
255 mm
Network type
DC
control type
Toggle
product name
ComPact NSX DC
Characteristic
Value(s)
Product weight
7.9 kg
Trip unit name
TM-DC
Number of poles
4P
Protection type
L : for overload protection (thermal) I : for short-circuit protection (magnetic)
Connection pitch
45 mm
Mounting support
Backplate
Neutral position
Left
Range of product
ComPact NSX400...630 DC
Trip unit rating
250 A at 40 °C
Device short name
NSX250F DC
Performance level
F 36 kA 750 V DC
Upside connection
Front
Device application
Distribution
[In] rated current
250 A at 40 °C
Downside connection
Front
Trip unit technology
Thermal-magnetic
Utilisation category
Category A
Electrical durability
1000 cycles at 750 V In 2000 cycles at 750 V In/2
Mechanical durability
5000 cycles
Earth-leakage protection
Without
Product or component type
Circuit breaker
Suitability for isolation
Yes conforming to EN/IEC 60947-2
Protected poles description
4t
Circuit breaker mounting mode
Fixed
[Ui] rated insulation voltage
750 V DC conforming to IEC 60947-2
[Ue] rated operational voltage
750 V DC
[Uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947-2
Number of slots for electrical auxiliaries
6 slot(s)
[Ir] long-time protection pick-up adjustment range
0.7...1 x In
[Ics] rated service short-circuit breaking capacity
36 kA at 750 V DC conforming to IEC 60947-2
[Icu] rated ultimate short-circuit breaking capacity
36 kA Icu at 250 V DC 1P conforming to IEC 60947-2 36 kA Icu at 500 V DC 2P conforming to IEC 60947-2 36 kA Icu at 750 V DC 3P conforming to IEC 60947-2 36 kA Icu at 750 V DC 4P conforming to IEC 60947-2
Long-time pick-up adjustment type Ir (thermal protection)
Adjustable

Compatibility Information

Match LV438260 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LV438260.

Maintenance Tips

Store LV438260 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options