+86 13348028050
LV433576 Schneider Electric LV433576 - Front View | Vcocnc FANUC Parts

Schneider Electric LV433576

Product information

SKU: LV433576

Alternate: LV433576

Brand
Schneider Electric
Part No.
LV433576
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LV433576 Product overview The Schneider Electric LV433576 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Circuit breaker mounting mode: Fixed - Complementary motor protection: Phase unbalance - Connection pitch: 1.4 in (35 mm) - Control Type: Toggle - Device Application: Motor - Device short name: NSX250HB2 - Downside connection: Front - Electrical durability: 5000 cycles 690 V In 10000 cycles 690 V In/2 10000 cycles 440 V In 20000 cycles 440 V In/2 - Line Rated Current: 150 A 149 °F (65 °C) - Long-time pick-up adjustment type Ir (thermal protection): Adjustable 9 settings - Long-time protection delay adjustment type tr: Fixed - Mechanical durability: 20000 cycles - Motor tripping class: 5 10 20 - Mounting Support: Backplate - Network Frequency: 50/60 Hz - Network type: AC - Number of poles: 3P - Performance level: HB2 100 kA 690 V AC - Product or Component Type: Circuit breaker - Protected poles description: 3t - Protection type: L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection - Range: ComPact - Range of Product: ComPact NSX100...250 - Suitability for isolation: Yes EN/IEC 60947-2 - Thermal memory: 20 minutes before and after tripping - Trip unit name: MicroLogic 2.2 M - Trip unit protection functions: LSoI - Trip unit rating: 150 A 149 °F (65 °C) - Trip unit technology: Electronic - Upside connection: Front - Utilisation category: Category A - [Ics] rated service short-circuit breaking capacity: 100 kA 500 V AC 50/60 Hz IEC 60947-2 100 kA 525 V AC 50/60 Hz IEC 60947-2 100 kA 660/690 V AC 50/60 Hz IEC 60947-2 - [Icu] rated ultimate short-circuit breaking capacity: 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 525 V AC 50/60 Hz IEC 60947-2 100 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2 - [Ir] long-time protection pick-up adjustment range: 70...150 A - [Ue] rated operational voltage: 690 V AC 50/60 Hz - [Ui] rated insulation voltage: 800 V AC 50/60 Hz - [Uimp] rated impulse withstand voltage: 8 kV - [tr] long-time protection delay adjustment range: 10 s 7.2 x Ir 10 120 s 1.5 x Ir 5 20 s 7.2 x Ir 20 240 s 1.5 x Ir 10 26 s 6 x Ir 20 480 s 1.5 x Ir 20 5 s 7.2 x Ir 5 13.5 s 6 x Ir 10 6.5 s 6 x Ir 5 - product name: ComPact NSX Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LV433576 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LV433576
Brand
Schneider Electric
Part Number
LV433576
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
ComPact
Control Type
Toggle
Network type
AC
product name
ComPact NSX
Characteristic
Value(s)
Thermal memory
20 minutes before and after tripping
Trip unit name
MicroLogic 2.2 M
Number of poles
3P
Protection type
L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection
Connection pitch
1.4 in (35 mm)
Mounting Support
Backplate
Range of Product
ComPact NSX100...250
Trip unit rating
150 A 149 °F (65 °C)
Device short name
NSX250HB2
Network Frequency
50/60 Hz
Performance level
HB2 100 kA 690 V AC
Upside connection
Front
Device Application
Motor
Line Rated Current
150 A 149 °F (65 °C)
Downside connection
Front
Motor tripping class
5 10 20
Trip unit technology
Electronic
Utilisation category
Category A
Electrical durability
5000 cycles 690 V In 10000 cycles 690 V In/2 10000 cycles 440 V In 20000 cycles 440 V In/2
Mechanical durability
20000 cycles
Product or Component Type
Circuit breaker
Suitability for isolation
Yes EN/IEC 60947-2
Protected poles description
3t
Circuit breaker mounting mode
Fixed
[Ui] rated insulation voltage
800 V AC 50/60 Hz
Complementary motor protection
Phase unbalance
Trip unit protection functions
LSoI
[Ue] rated operational voltage
690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
Long-time protection delay adjustment type tr
Fixed
[tr] long-time protection delay adjustment range
10 s 7.2 x Ir 10 120 s 1.5 x Ir 5 20 s 7.2 x Ir 20 240 s 1.5 x Ir 10 26 s 6 x Ir 20 480 s 1.5 x Ir 20 5 s 7.2 x Ir 5 13.5 s 6 x Ir 10 6.5 s 6 x Ir 5
[Ir] long-time protection pick-up adjustment range
70...150 A
[Ics] rated service short-circuit breaking capacity
100 kA 500 V AC 50/60 Hz IEC 60947-2 100 kA 525 V AC 50/60 Hz IEC 60947-2 100 kA 660/690 V AC 50/60 Hz IEC 60947-2
[Icu] rated ultimate short-circuit breaking capacity
100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 525 V AC 50/60 Hz IEC 60947-2 100 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2
Long-time pick-up adjustment type Ir (thermal protection)
Adjustable 9 settings

Compatibility Information

Match LV433576 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LV433576.

Maintenance Tips

Store LV433576 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options