+86 13348028050
LV433502 Schneider Electric LV433502 - Front View | Vcocnc FANUC Parts

Schneider Electric LV433502

Product information

SKU: LV433502

Alternate: LV433502

Brand
Schneider Electric
Part No.
LV433502
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LV433502 Product overview The Schneider Electric LV433502 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Circuit breaker mounting mode: Fixed - Connection pitch: 1.4 in (35 mm) - Control Type: Toggle - Depth (D): 3.4 in (86 mm) - Device Application: Motor - Device short name: NSX250HB1 - Downside connection: Front - Earth-leakage protection: Without - Electrical durability: 5000 cycles 690 V In 10000 cycles 690 V In/2 10000 cycles 440 V In 20000 cycles 440 V In/2 - Height (H): 6.3 in (161 mm) - Line Rated Current: 150 A 149 °F (65 °C) - Mechanical durability: 20000 cycles - Mounting Support: Backplate - Network Frequency: 50/60 Hz - Network type: AC - Number of poles: 3P - Number of slots for electrical auxiliaries: 5 - Performance level: HB1 75 kA 690 V AC - Product or Component Type: Circuit breaker - Protected poles description: 3t - Protection type: I : for short-circuit protection (magnetic) - Range: ComPact - Range of Product: ComPact NSX100...250 - Short-time protection pick-up adjustment type Isd: Adjustable - Suitability for isolation: Yes EN/IEC 60947-2 - Trip unit name: MA - Trip unit protection functions: I - Trip unit rating: 150 A 149 °F (65 °C) - Trip unit technology: Magnetic - Upside connection: Front - Utilisation category: Category A - Width (W): 4.1 in (105 mm) - [Ics] rated service short-circuit breaking capacity: 85 kA 500 V AC 50/60 Hz IEC 60947-2 80 kA 525 V AC 50/60 Hz IEC 60947-2 75 kA 660/690 V AC 50/60 Hz IEC 60947-2 - [Icu] rated ultimate short-circuit breaking capacity: 85 kA Icu 500 V AC 50/60 Hz IEC 60947-2 80 kA Icu 525 V AC 50/60 Hz IEC 60947-2 75 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2 - [Isd] Short-time protection pick-up adjustment range: 9...14 x In - [Ue] rated operational voltage: 690 V AC 50/60 Hz - [Ui] rated insulation voltage: 800 V AC 50/60 Hz - [Uimp] rated impulse withstand voltage: 8 kV - product name: ComPact NSX Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LV433502 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LV433502
Brand
Schneider Electric
Part Number
LV433502
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
ComPact
Depth (D)
3.4 in (86 mm)
Width (W)
4.1 in (105 mm)
Height (H)
6.3 in (161 mm)
Control Type
Toggle
Network type
AC
product name
ComPact NSX
Characteristic
Value(s)
Trip unit name
MA
Number of poles
3P
Protection type
I : for short-circuit protection (magnetic)
Connection pitch
1.4 in (35 mm)
Mounting Support
Backplate
Range of Product
ComPact NSX100...250
Trip unit rating
150 A 149 °F (65 °C)
Device short name
NSX250HB1
Network Frequency
50/60 Hz
Performance level
HB1 75 kA 690 V AC
Upside connection
Front
Device Application
Motor
Line Rated Current
150 A 149 °F (65 °C)
Downside connection
Front
Trip unit technology
Magnetic
Utilisation category
Category A
Electrical durability
5000 cycles 690 V In 10000 cycles 690 V In/2 10000 cycles 440 V In 20000 cycles 440 V In/2
Mechanical durability
20000 cycles
Earth-leakage protection
Without
Product or Component Type
Circuit breaker
Suitability for isolation
Yes EN/IEC 60947-2
Protected poles description
3t
Circuit breaker mounting mode
Fixed
[Ui] rated insulation voltage
800 V AC 50/60 Hz
Trip unit protection functions
I
[Ue] rated operational voltage
690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
Number of slots for electrical auxiliaries
5
Short-time protection pick-up adjustment type Isd
Adjustable
[Ics] rated service short-circuit breaking capacity
85 kA 500 V AC 50/60 Hz IEC 60947-2 80 kA 525 V AC 50/60 Hz IEC 60947-2 75 kA 660/690 V AC 50/60 Hz IEC 60947-2
[Icu] rated ultimate short-circuit breaking capacity
85 kA Icu 500 V AC 50/60 Hz IEC 60947-2 80 kA Icu 525 V AC 50/60 Hz IEC 60947-2 75 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2
[Isd] Short-time protection pick-up adjustment range
9...14 x In

Compatibility Information

Match LV433502 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LV433502.

Maintenance Tips

Store LV433502 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options