+86 13348028050
LV433213 Schneider Electric LV433213 - Front View | Vcocnc FANUC Parts

Schneider Electric LV433213

Product information

SKU: LV433213

Alternate: LV433213

Brand
Schneider Electric
Part No.
LV433213
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LV433213 Product overview The Schneider Electric LV433213 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Circuit breaker mounting mode: Fixed - Connection pitch: 1.4 in (35 mm) - Control Type: Toggle - Device Application: Distribution - Device short name: NSX100HB1 - Downside connection: Front - Electrical durability: 10000 cycles 690 V In 20000 cycles 690 V In/2 30000 cycles 440 V In 50000 cycles 440 V In/2 - Line Rated Current: 50 A 104 °F (40 °C) - Long-time pick-up adjustment type Ir (thermal protection): Adjustable - Long-time protection delay adjustment type tr: Fixed - Mechanical durability: 50000 cycles - Mounting Support: Backplate - Network Frequency: 50/60 Hz - Network type: AC - Neutral position: Left - Number of poles: 4P - Performance level: HB1 75 kA 690 V AC - Product or Component Type: Circuit breaker - Protected poles description: 4t - Protection type: L : for overload protection (thermal) I : for short-circuit protection (magnetic) - Range: ComPact - Range of Product: ComPact NSX100...250 - Short-time protection pick-up adjustment type Isd: Fixed - Suitability for isolation: Yes EN/IEC 60947-2 - Trip unit name: TM-D - Trip unit protection functions: LI - Trip unit rating: 50 A 104 °F (40 °C) - Trip unit technology: Thermal-magnetic - Upside connection: Front - Utilisation category: Category A - [Ics] rated service short-circuit breaking capacity: 85 kA 500 V AC 50/60 Hz IEC 60947-2 80 kA 525 V AC 50/60 Hz IEC 60947-2 75 kA 660/690 V AC 50/60 Hz IEC 60947-2 - [Icu] rated ultimate short-circuit breaking capacity: 85 kA Icu 500 V AC 50/60 Hz IEC 60947-2 80 kA Icu 525 V AC 50/60 Hz IEC 60947-2 75 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2 - [Ir] long-time protection pick-up adjustment range: 0.7...1 x In - [Isd] Short-time protection pick-up adjustment range: 500 A - [Ue] rated operational voltage: 690 V AC 50/60 Hz - [Ui] rated insulation voltage: 800 V AC 50/60 Hz - [Uimp] rated impulse withstand voltage: 8 kV - [tr] long-time protection delay adjustment range: 120…400 s 1.5 x In 15 s 6 x Ir - product name: ComPact NSX Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LV433213 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LV433213
Brand
Schneider Electric
Part Number
LV433213
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
ComPact
Control Type
Toggle
Network type
AC
product name
ComPact NSX
Characteristic
Value(s)
Trip unit name
TM-D
Number of poles
4P
Protection type
L : for overload protection (thermal) I : for short-circuit protection (magnetic)
Connection pitch
1.4 in (35 mm)
Mounting Support
Backplate
Neutral position
Left
Range of Product
ComPact NSX100...250
Trip unit rating
50 A 104 °F (40 °C)
Device short name
NSX100HB1
Network Frequency
50/60 Hz
Performance level
HB1 75 kA 690 V AC
Upside connection
Front
Device Application
Distribution
Line Rated Current
50 A 104 °F (40 °C)
Downside connection
Front
Trip unit technology
Thermal-magnetic
Utilisation category
Category A
Electrical durability
10000 cycles 690 V In 20000 cycles 690 V In/2 30000 cycles 440 V In 50000 cycles 440 V In/2
Mechanical durability
50000 cycles
Product or Component Type
Circuit breaker
Suitability for isolation
Yes EN/IEC 60947-2
Protected poles description
4t
Circuit breaker mounting mode
Fixed
[Ui] rated insulation voltage
800 V AC 50/60 Hz
Trip unit protection functions
LI
[Ue] rated operational voltage
690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
Long-time protection delay adjustment type tr
Fixed
[tr] long-time protection delay adjustment range
120…400 s 1.5 x In 15 s 6 x Ir
Short-time protection pick-up adjustment type Isd
Fixed
[Ir] long-time protection pick-up adjustment range
0.7...1 x In
[Ics] rated service short-circuit breaking capacity
85 kA 500 V AC 50/60 Hz IEC 60947-2 80 kA 525 V AC 50/60 Hz IEC 60947-2 75 kA 660/690 V AC 50/60 Hz IEC 60947-2
[Icu] rated ultimate short-circuit breaking capacity
85 kA Icu 500 V AC 50/60 Hz IEC 60947-2 80 kA Icu 525 V AC 50/60 Hz IEC 60947-2 75 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2
[Isd] Short-time protection pick-up adjustment range
500 A
Long-time pick-up adjustment type Ir (thermal protection)
Adjustable

Compatibility Information

Match LV433213 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LV433213.

Maintenance Tips

Store LV433213 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options