+86 13348028050
LV431790 Schneider Electric LV431790 - Front View | Vcocnc FANUC Parts

Schneider Electric LV431790

Product information

$419.04 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: LV431790

Alternate: LV431790

Brand
Schneider Electric
Part No.
LV431790
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LV431790 Product overview The Schneider Electric LV431790 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Circuit breaker mounting mode: Fixed - Connection pitch: 1.4 in (35 mm) - Control Type: Toggle - Device Application: Distribution - Device short name: NSX250H - Downside connection: Front - Electrical durability: 5000 cycles 690 V In 10000 cycles 690 V In/2 10000 cycles 440 V In 20000 cycles 440 V In/2 - Line Rated Current: 250 A 104 °F (40 °C) - Long-time pick-up adjustment type Ir (thermal protection): Adjustable 9 settings - Long-time protection delay adjustment type tr: Fixed - Mechanical durability: 20000 cycles - Mounting Support: Backplate - Network Frequency: 50/60 Hz - Network type: AC - Number of poles: 3P - Performance level: H 70 kA 415 V AC - Product or Component Type: Circuit breaker - Protected poles description: 3t - Protection type: L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection - Range: ComPact - Range of Product: ComPact NSX100...250 - Short-time protection pick-up adjustment type Isd: Adjustable 9 settings - Suitability for isolation: Yes EN/IEC 60947-2 - Thermal memory: 20 minutes before and after tripping - Trip unit name: MicroLogic 2.2 - Trip unit protection functions: LSoI - Trip unit rating: 250 A 104 °F (40 °C) - Trip unit technology: Electronic - Upside connection: Front - Utilisation category: Category A - [Ics] rated service short-circuit breaking capacity: 10 kA 660/690 V AC 50/60 Hz IEC 60947-2 100 kA 220/240 V AC 50/60 Hz IEC 60947-2 35 kA 525 V AC 50/60 Hz IEC 60947-2 50 kA 500 V AC 50/60 Hz IEC 60947-2 65 kA 440 V AC 50/60 Hz IEC 60947-2 70 kA 380/415 V AC 50/60 Hz IEC 60947-2 - [Icu] rated ultimate short-circuit breaking capacity: 85 kA 240 V AC 50/60 Hz UL 508 65 kA 480 V AC 50/60 Hz UL 508 10 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2 100 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 35 kA Icu 525 V AC 50/60 Hz IEC 60947-2 50 kA Icu 500 V AC 50/60 Hz IEC 60947-2 65 kA Icu 440 V AC 50/60 Hz IEC 60947-2 70 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 15 kA 600 V AC 50/60 Hz UL 508 - [Ir] long-time protection pick-up adjustment range: 100...250 A - [Isd] Short-time protection pick-up adjustment range: 1.5...10 x Ir - [Ue] rated operational voltage: 690 V AC 50/60 Hz - [Ui] rated insulation voltage: 800 V AC 50/60 Hz - [Uimp] rated impulse withstand voltage: 8 kV - [tr] long-time protection delay adjustment range: 11 s 7.2 x Ir 16 s 6 x Ir 400 s 1.5 x Ir - product name: ComPact NSX Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LV431790 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LV431790
Brand
Schneider Electric
Part Number
LV431790
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
ComPact
Packaging
New surplus, factory sealed original packaging
Control Type
Toggle
Network type
AC
product name
ComPact NSX
Characteristic
Value(s)
Thermal memory
20 minutes before and after tripping
Trip unit name
MicroLogic 2.2
Number of poles
3P
Protection type
L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection
Connection pitch
1.4 in (35 mm)
Mounting Support
Backplate
Range of Product
ComPact NSX100...250
Trip unit rating
250 A 104 °F (40 °C)
Device short name
NSX250H
Network Frequency
50/60 Hz
Performance level
H 70 kA 415 V AC
Upside connection
Front
Device Application
Distribution
Line Rated Current
250 A 104 °F (40 °C)
Downside connection
Front
Trip unit technology
Electronic
Utilisation category
Category A
Electrical durability
5000 cycles 690 V In 10000 cycles 690 V In/2 10000 cycles 440 V In 20000 cycles 440 V In/2
Mechanical durability
20000 cycles
Product or Component Type
Circuit breaker
Suitability for isolation
Yes EN/IEC 60947-2
Protected poles description
3t
Circuit breaker mounting mode
Fixed
[Ui] rated insulation voltage
800 V AC 50/60 Hz
Trip unit protection functions
LSoI
[Ue] rated operational voltage
690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
Long-time protection delay adjustment type tr
Fixed
[tr] long-time protection delay adjustment range
11 s 7.2 x Ir 16 s 6 x Ir 400 s 1.5 x Ir
Short-time protection pick-up adjustment type Isd
Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range
100...250 A
[Ics] rated service short-circuit breaking capacity
10 kA 660/690 V AC 50/60 Hz IEC 60947-2 100 kA 220/240 V AC 50/60 Hz IEC 60947-2 35 kA 525 V AC 50/60 Hz IEC 60947-2 50 kA 500 V AC 50/60 Hz IEC 60947-2 65 kA 440 V AC 50/60 Hz IEC 60947-2 70 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Icu] rated ultimate short-circuit breaking capacity
85 kA 240 V AC 50/60 Hz UL 508 65 kA 480 V AC 50/60 Hz UL 508 10 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2 100 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 35 kA Icu 525 V AC 50/60 Hz IEC 60947-2 50 kA Icu 500 V AC 50/60 Hz IEC 60947-2 65 kA Icu 440 V AC 50/60 Hz IEC 60947-2 70 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 15 kA 600 V AC 50/60 Hz UL 508
[Isd] Short-time protection pick-up adjustment range
1.5...10 x Ir
Long-time pick-up adjustment type Ir (thermal protection)
Adjustable 9 settings

Compatibility Information

Match LV431790 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LV431790.

Maintenance Tips

Store LV431790 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options