+86 13348028050
LV429015 Schneider Electric LV429015 - Front View | Vcocnc FANUC Parts

Schneider Electric LV429015

Product information

$610.01 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: LV429015

Alternate: LV429015

Brand
Schneider Electric
Part No.
LV429015
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LV429015 Product overview The Schneider Electric LV429015 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Circuit breaker name: Compact NSX100B - Connection pitch: 1.4 in (35 mm) - Control Type: Toggle - Depth (D): 3.4 in (86 mm) - Device Application: Distribution - Device short name: NSX100B - Downside connection: Front - Electrical durability: 10000 cycles 690 V AC 50/60 Hz In IEC 60947-2 20000 cycles 690 V AC 50/60 Hz In/2 IEC 60947-2 30000 cycles 440 V AC 50/60 Hz In IEC 60947-2 50000 cycles 440 V AC 50/60 Hz In/2 IEC 60947-2 - Height (H): 6.3 in (161 mm) - Line Rated Current: 100 A 104 °F (40 °C) - Mechanical durability: 50000 cycles IEC 60947-2 - Mounting Mode: Fixed - Mounting Support: Backplate - Network Frequency: 50/60 Hz - Network type: AC - Neutral position: Left - Number of poles: 4P - Performance level: B 25 kA 415 V AC - Product or Component Type: Basic frame - Protection Type: Without protection - Range: ComPact - Range of Product: ComPact NSX100...250 - Suitability for isolation: Yes EN/IEC 60947-2 - Upside connection: Front - Utilisation category: Category A - Width (W): 5.5 in (140 mm) - [Ics] rated service short-circuit breaking capacity: 20 kA 440 V AC 50/60 Hz IEC 60947-2 25 kA 380/415 V AC 50/60 Hz IEC 60947-2 40 kA 220/240 V AC 50/60 Hz IEC 60947-2 7.5 kA 500 V AC 50/60 Hz IEC 60947-2 - [Icu] rated ultimate short-circuit breaking capacity: 15 kA Icu 500 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 25 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 40 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 - [Ue] rated operational voltage: 690 V AC 50/60 Hz - [Ui] rated insulation voltage: 800 V AC 50/60 Hz IEC 60947-2 - [Uimp] rated impulse withstand voltage: 8 kVIEC 60947-2 Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LV429015 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LV429015
Brand
Schneider Electric
Part Number
LV429015
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
ComPact
Depth (D)
3.4 in (86 mm)
Packaging
New surplus, never used
Width (W)
5.5 in (140 mm)
Height (H)
6.3 in (161 mm)
Control Type
Toggle
Network type
AC
Mounting Mode
Fixed
Characteristic
Value(s)
Number of poles
4P
Protection Type
Without protection
Connection pitch
1.4 in (35 mm)
Mounting Support
Backplate
Neutral position
Left
Range of Product
ComPact NSX100...250
Device short name
NSX100B
Network Frequency
50/60 Hz
Performance level
B 25 kA 415 V AC
Upside connection
Front
Device Application
Distribution
Line Rated Current
100 A 104 °F (40 °C)
Downside connection
Front
Circuit breaker name
Compact NSX100B
Utilisation category
Category A
Electrical durability
10000 cycles 690 V AC 50/60 Hz In IEC 60947-2 20000 cycles 690 V AC 50/60 Hz In/2 IEC 60947-2 30000 cycles 440 V AC 50/60 Hz In IEC 60947-2 50000 cycles 440 V AC 50/60 Hz In/2 IEC 60947-2
Mechanical durability
50000 cycles IEC 60947-2
Product or Component Type
Basic frame
Suitability for isolation
Yes EN/IEC 60947-2
[Ui] rated insulation voltage
800 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage
690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kVIEC 60947-2
[Ics] rated service short-circuit breaking capacity
20 kA 440 V AC 50/60 Hz IEC 60947-2 25 kA 380/415 V AC 50/60 Hz IEC 60947-2 40 kA 220/240 V AC 50/60 Hz IEC 60947-2 7.5 kA 500 V AC 50/60 Hz IEC 60947-2
[Icu] rated ultimate short-circuit breaking capacity
15 kA Icu 500 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 25 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 40 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2

Compatibility Information

Match LV429015 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LV429015.

Maintenance Tips

Store LV429015 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options