Schneider Electric LUCM32BL
Product information
$651.75 USD
Condition: newShipping calculated at checkout ( Shipping Policy · 30-Day Returns )
SKU: LUCM32BL
Alternate: LUCM32BL
Brand
Schneider Electric
Part No.
LUCM32BL
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
Schneider Electric LUCM32BL
Product overview
The Schneider Electric LUCM32BL is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Characteristic: Value(s)
- Control circuit voltage limits: 20...28 V DC 24 V in operation 14.5 V DC 24 V drop-out
- Depth: 2.4 in (60 mm)
- Device Application: Motor control Motor protection
- Device short name: LUCM
- Fixing mode: Plug-in (front face)
- Heat dissipation: 1.8 W control circuit with LUB32 1.8 W control circuit with LUB38 0.8 W external auxiliary circuit
- Height: 2.6 in (66 mm)
- Information displayed: Average current factory setting) Average current settable) Cause of last 5 faults settable) Current in phase settable) Earth leakage current settable) Phase imbalance settable) Thermal state of motor settable)
- Load type: 3-phase motor self-cooled factory setting 3-phase motor self-cooled, force cooled settable Single-phase motor self-cooled, force cooled settable
- Messages display capacity: 2 lines of 12 characters LCD - English +/- 5 % 1 % of Ir 2 lines of 12 characters LCD - French +/- 5 % 1 % of Ir 2 lines of 12 characters LCD - German +/- 5 % 1 % of Ir 2 lines of 12 characters LCD - Italian +/- 5 % 1 % of Ir 2 lines of 12 characters LCD - Spanish +/- 5 % 1 % of Ir
- Motor power kW: 15 kW 400...440 V AC 50/60 Hz 3 phase 15 kW 500 V AC 50/60 Hz 3 phase 18.5 kW 690 V AC 50/60 Hz 3 phase 7.5 kW 400...440 V AC 50/60 Hz 1 phase
- Network frequency: 40...60 Hz
- Operating time: 35 ms opening with LUB32 control circuit 35 ms opening with LUB38 control circuit 65 ms closing with LUB32 control circuit 65 ms closing with LUB38 control circuit
- Physical interface: RS485 multidrop RJ45 front panel Modbus RTU 19200 bit/s
- Product Certifications: CE UL CSA CCC EAC ASEFA ATEX Marine
- Product Specific Application: Most sophisticated control and protection requirements, with display
- Product Weight: 0.386 lb(US) (0.175 kg)
- Product compatibility: Power base LUB32 Power base LUB38 Power base LUB320 Power base LUB380 Reversing contactor breaker LU2B32FU Reversing contactor breaker LU2B38FU
- Product or Component Type: Multifunction control unit
- Range: TeSys
- Range of Product: TeSys Ultra
- Reset: Automatic reset setting range Manual factory setting Manual setting range Remote reset setting range
- Return time: <= 200 ms
- Safe separation of circuit: 400 V SELV between the control and auxiliary circuits IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
- Standards: EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier
- Thermal overload class: Class 5â¦30 50â¦60 Hz -13â¦131 °F (-25â¦55 °C) IEC 60947-6-2 Class 5â¦30 50â¦60 Hz -13â¦131 °F (-25â¦55 °C) UL 508
- Time before reset: 1â¦1000 s manual or automatic reset settable 120 s manual factory setting
- Tripping threshold: 14.2 x Ir +/- 20 %
- Typical current consumption: 220 mA 24 V DC I maximum while closing with LUB32 220 mA 24 V DC I maximum while closing with LUB38 80 mA 24 V DC I rms sealed with LUB32 80 mA 24 V DC I rms sealed with LUB38
- User language: English factory setting English, French, German, Italian, Spanish settable
- Utilisation category: AC-43 AC-41 AC-44
- Width: 1.8 in (45 mm)
- [Uc] control circuit voltage: 24 V DC
- [Ue] rated operational voltage: 690 V AC
- [Ui] rated insulation voltage: 690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1
- [Uimp] rated impulse withstand voltage: 6 kV IEC 60947-6-2
- main function available: Manual or automatic reset Monitoring function, indication of main motor parameters Overload, no-load running Protection function alarm Protection against overload and short-circuit Protection against phase failure and phase imbalance Earth fault protection Log function Differentiation of thermal overload and magnetic fault
- product name: TeSys Ultra
- rated motor current adjustment range: 8â¦32 A
Condition and supply
- New surplus, never used
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number LUCM32BL with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- LUCM32BL
- Brand
- Schneider Electric
- Part Number
- LUCM32BL
- Category
- Schneider Electric Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Depth
- 2.4 in (60 mm)
- Range
- TeSys
- Reset
- Automatic reset setting range Manual factory setting Manual setting range Remote reset setting range
- Width
- 1.8 in (45 mm)
- Height
- 2.6 in (66 mm)
- Load type
- 3-phase motor self-cooled factory setting 3-phase motor self-cooled, force cooled settable Single-phase motor self-cooled, force cooled settable
- Packaging
- New surplus, never used
- Standards
- EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier
- Fixing mode
- Plug-in (front face)
- Return time
- <= 200 ms
- product name
- TeSys Ultra
- User language
- English factory setting English, French, German, Italian, Spanish settable
- Characteristic
- Value(s)
- Motor power kW
- 15 kW 400...440 V AC 50/60 Hz 3 phase 15 kW 500 V AC 50/60 Hz 3 phase 18.5 kW 690 V AC 50/60 Hz 3 phase 7.5 kW 400...440 V AC 50/60 Hz 1 phase
- Operating time
- 35 ms opening with LUB32 control circuit 35 ms opening with LUB38 control circuit 65 ms closing with LUB32 control circuit 65 ms closing with LUB38 control circuit
- Product Weight
- 0.386 lb(US) (0.175 kg)
- Heat dissipation
- 1.8 W control circuit with LUB32 1.8 W control circuit with LUB38 0.8 W external auxiliary circuit
- Range of Product
- TeSys Ultra
- Device short name
- LUCM
- Network frequency
- 40...60 Hz
- Time before reset
- 1â¦1000 s manual or automatic reset settable 120 s manual factory setting
- Device Application
- Motor control Motor protection
- Physical interface
- RS485 multidrop RJ45 front panel Modbus RTU 19200 bit/s
- Tripping threshold
- 14.2 x Ir +/- 20 %
- Utilisation category
- AC-43 AC-41 AC-44
- Information displayed
- Average current factory setting) Average current settable) Cause of last 5 faults settable) Current in phase settable) Earth leakage current settable) Phase imbalance settable) Thermal state of motor settable)
- Product compatibility
- Power base LUB32 Power base LUB38 Power base LUB320 Power base LUB380 Reversing contactor breaker LU2B32FU Reversing contactor breaker LU2B38FU
- Product Certifications
- CE UL CSA CCC EAC ASEFA ATEX Marine
- Thermal overload class
- Class 5â¦30 50â¦60 Hz -13â¦131 °F (-25â¦55 °C) IEC 60947-6-2 Class 5â¦30 50â¦60 Hz -13â¦131 °F (-25â¦55 °C) UL 508
- main function available
- Manual or automatic reset Monitoring function, indication of main motor parameters Overload, no-load running Protection function alarm Protection against overload and short-circuit Protection against phase failure and phase imbalance Earth fault protection Log function Differentiation of thermal overload and magnetic fault
- Messages display capacity
- 2 lines of 12 characters LCD - English +/- 5 % 1 % of Ir 2 lines of 12 characters LCD - French +/- 5 % 1 % of Ir 2 lines of 12 characters LCD - German +/- 5 % 1 % of Ir 2 lines of 12 characters LCD - Italian +/- 5 % 1 % of Ir 2 lines of 12 characters LCD - Spanish +/- 5 % 1 % of Ir
- Product or Component Type
- Multifunction control unit
- Safe separation of circuit
- 400 V SELV between the control and auxiliary circuits IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
- Typical current consumption
- 220 mA 24 V DC I maximum while closing with LUB32 220 mA 24 V DC I maximum while closing with LUB38 80 mA 24 V DC I rms sealed with LUB32 80 mA 24 V DC I rms sealed with LUB38
- Product Specific Application
- Most sophisticated control and protection requirements, with display
- [Uc] control circuit voltage
- 24 V DC
- [Ui] rated insulation voltage
- 690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1
- Control circuit voltage limits
- 20...28 V DC 24 V in operation 14.5 V DC 24 V drop-out
- [Ue] rated operational voltage
- 690 V AC
- rated motor current adjustment range
- 8â¦32 A
- [Uimp] rated impulse withstand voltage
- 6 kV IEC 60947-6-2
Compatibility Information
Match LUCM32BL against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the Schneider Electric documentation for the host system when replacing LUCM32BL.
Maintenance Tips
Store LUCM32BL dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. LUCM32BL is in stock and ships within 1-2 business days, with a tracking number for every shipment.
LUCM32BL is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match LUCM32BL against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
Schneider Electric ZR2FA2
SKU: ZR2FA2
Schneider Electric ZMLPA2P0SH
SKU: ZMLPA2P0SH
Schneider Electric ZMLPA2N0SH
SKU: ZMLPA2N0SH
Schneider Electric ZMLPA1P2SW
SKU: ZMLPA1P2SW