Schneider Electric LUCM32BL Product overview The Schneider Electric LUCM32BL is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Control circuit voltage limits: 20...28 V DC 24 V in operation 14.5 V DC 24 V drop-out - Depth: 2.4 in (60 mm) - Device Application: Motor control Motor protection - Device short name: LUCM - Fixing mode: Plug-in (front face) - Heat dissipation: 1.8 W control circuit with LUB32 1.8 W control circuit with LUB38 0.8 W external auxiliary circuit - Height: 2.6 in (66 mm) - Information displayed: Average current factory setting) Average current settable) Cause of last 5 faults settable) Current in phase settable) Earth leakage current settable) Phase imbalance settable) Thermal state of motor settable) - Load type: 3-phase motor self-cooled factory setting 3-phase motor self-cooled, force cooled settable Single-phase motor self-cooled, force cooled settable - Messages display capacity: 2 lines of 12 characters LCD - English +/- 5 % 1 % of Ir 2 lines of 12 characters LCD - French +/- 5 % 1 % of Ir 2 lines of 12 characters LCD - German +/- 5 % 1 % of Ir 2 lines of 12 characters LCD - Italian +/- 5 % 1 % of Ir 2 lines of 12 characters LCD - Spanish +/- 5 % 1 % of Ir - Motor power kW: 15 kW 400...440 V AC 50/60 Hz 3 phase 15 kW 500 V AC 50/60 Hz 3 phase 18.5 kW 690 V AC 50/60 Hz 3 phase 7.5 kW 400...440 V AC 50/60 Hz 1 phase - Network frequency: 40...60 Hz - Operating time: 35 ms opening with LUB32 control circuit 35 ms opening with LUB38 control circuit 65 ms closing with LUB32 control circuit 65 ms closing with LUB38 control circuit - Physical interface: RS485 multidrop RJ45 front panel Modbus RTU 19200 bit/s - Product Certifications: CE UL CSA CCC EAC ASEFA ATEX Marine - Product Specific Application: Most sophisticated control and protection requirements, with display - Product Weight: 0.386 lb(US) (0.175 kg) - Product compatibility: Power base LUB32 Power base LUB38 Power base LUB320 Power base LUB380 Reversing contactor breaker LU2B32FU Reversing contactor breaker LU2B38FU - Product or Component Type: Multifunction control unit - Range: TeSys - Range of Product: TeSys Ultra - Reset: Automatic reset setting range Manual factory setting Manual setting range Remote reset setting range - Return time: <= 200 ms - Safe separation of circuit: 400 V SELV between the control and auxiliary circuits IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 - Standards: EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier - Thermal overload class: Class 5…30 50…60 Hz -13…131 °F (-25…55 °C) IEC 60947-6-2 Class 5…30 50…60 Hz -13…131 °F (-25…55 °C) UL 508 - Time before reset: 1…1000 s manual or automatic reset settable 120 s manual factory setting - Tripping threshold: 14.2 x Ir +/- 20 % - Typical current consumption: 220 mA 24 V DC I maximum while closing with LUB32 220 mA 24 V DC I maximum while closing with LUB38 80 mA 24 V DC I rms sealed with LUB32 80 mA 24 V DC I rms sealed with LUB38 - User language: English factory setting English, French, German, Italian, Spanish settable - Utilisation category: AC-43 AC-41 AC-44 - Width: 1.8 in (45 mm) - [Uc] control circuit voltage: 24 V DC - [Ue] rated operational voltage: 690 V AC - [Ui] rated insulation voltage: 690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1 - [Uimp] rated impulse withstand voltage: 6 kV IEC 60947-6-2 - main function available: Manual or automatic reset Monitoring function, indication of main motor parameters Overload, no-load running Protection function alarm Protection against overload and short-circuit Protection against phase failure and phase imbalance Earth fault protection Log function Differentiation of thermal overload and magnetic fault - product name: TeSys Ultra - rated motor current adjustment range: 8…32 A Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LUCM32BL with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LUCM32BL
Brand
Schneider Electric
Part Number
LUCM32BL
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Depth
2.4 in (60 mm)
Range
TeSys
Reset
Automatic reset setting range Manual factory setting Manual setting range Remote reset setting range
Width
1.8 in (45 mm)
Height
2.6 in (66 mm)
Load type
3-phase motor self-cooled factory setting 3-phase motor self-cooled, force cooled settable Single-phase motor self-cooled, force cooled settable
Packaging
New surplus, never used
Standards
EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier
Fixing mode
Plug-in (front face)
Return time
<= 200 ms
product name
TeSys Ultra
User language
English factory setting English, French, German, Italian, Spanish settable
Characteristic
Value(s)
Motor power kW
15 kW 400...440 V AC 50/60 Hz 3 phase 15 kW 500 V AC 50/60 Hz 3 phase 18.5 kW 690 V AC 50/60 Hz 3 phase 7.5 kW 400...440 V AC 50/60 Hz 1 phase
Operating time
35 ms opening with LUB32 control circuit 35 ms opening with LUB38 control circuit 65 ms closing with LUB32 control circuit 65 ms closing with LUB38 control circuit
Product Weight
0.386 lb(US) (0.175 kg)
Heat dissipation
1.8 W control circuit with LUB32 1.8 W control circuit with LUB38 0.8 W external auxiliary circuit
Range of Product
TeSys Ultra
Device short name
LUCM
Network frequency
40...60 Hz
Time before reset
1…1000 s manual or automatic reset settable 120 s manual factory setting
Device Application
Motor control Motor protection
Physical interface
RS485 multidrop RJ45 front panel Modbus RTU 19200 bit/s
Tripping threshold
14.2 x Ir +/- 20 %
Utilisation category
AC-43 AC-41 AC-44
Information displayed
Average current factory setting) Average current settable) Cause of last 5 faults settable) Current in phase settable) Earth leakage current settable) Phase imbalance settable) Thermal state of motor settable)
Product compatibility
Power base LUB32 Power base LUB38 Power base LUB320 Power base LUB380 Reversing contactor breaker LU2B32FU Reversing contactor breaker LU2B38FU
Product Certifications
CE UL CSA CCC EAC ASEFA ATEX Marine
Thermal overload class
Class 5…30 50…60 Hz -13…131 °F (-25…55 °C) IEC 60947-6-2 Class 5…30 50…60 Hz -13…131 °F (-25…55 °C) UL 508
main function available
Manual or automatic reset Monitoring function, indication of main motor parameters Overload, no-load running Protection function alarm Protection against overload and short-circuit Protection against phase failure and phase imbalance Earth fault protection Log function Differentiation of thermal overload and magnetic fault
Messages display capacity
2 lines of 12 characters LCD - English +/- 5 % 1 % of Ir 2 lines of 12 characters LCD - French +/- 5 % 1 % of Ir 2 lines of 12 characters LCD - German +/- 5 % 1 % of Ir 2 lines of 12 characters LCD - Italian +/- 5 % 1 % of Ir 2 lines of 12 characters LCD - Spanish +/- 5 % 1 % of Ir
Product or Component Type
Multifunction control unit
Safe separation of circuit
400 V SELV between the control and auxiliary circuits IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Typical current consumption
220 mA 24 V DC I maximum while closing with LUB32 220 mA 24 V DC I maximum while closing with LUB38 80 mA 24 V DC I rms sealed with LUB32 80 mA 24 V DC I rms sealed with LUB38
Product Specific Application
Most sophisticated control and protection requirements, with display
[Uc] control circuit voltage
24 V DC
[Ui] rated insulation voltage
690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1
Control circuit voltage limits
20...28 V DC 24 V in operation 14.5 V DC 24 V drop-out
[Ue] rated operational voltage
690 V AC
rated motor current adjustment range
8…32 A
[Uimp] rated impulse withstand voltage
6 kV IEC 60947-6-2

Compatibility Information

Match LUCM32BL against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LUCM32BL.

Maintenance Tips

Store LUCM32BL dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options