Schneider Electric LUCDX6BL
Product information
SKU: LUCDX6BL
Alternate: LUCDX6BL
Brand
Schneider Electric
Part No.
LUCDX6BL
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
Schneider Electric LUCDX6BL
Product overview
The Schneider Electric LUCDX6BL is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Characteristic: Value(s)
- Compatibility code: LUCD
- Control circuit voltage limits: 20...27 V DC 24 V in operation 14.5 V DC 24 V drop-out
- Depth: 2.4 in (60 mm)
- Device Application: Motor control Motor protection
- Device short name: LUCD
- Fixing mode: Plug-in (front face)
- Heat dissipation: 2 W control circuit with LUB12 3 W control circuit with LUB32 3 W control circuit with LUB38
- Height: 2.6 in (66 mm)
- Load type: 3-phase motor self-cooled
- Motor power kW: 0.09 kW 400...440 V AC 50/60 Hz
- Network frequency: 40...60 Hz
- Operating time: 35 ms opening with LUB12 control circuit 35 ms opening with LUB32 control circuit 35 ms opening with LUB38 control circuit 70 ms closing with LUB12 control circuit 70 ms closing with LUB32 control circuit 70 ms closing with LUB38 control circuit
- Phase failure sensitivity: Yes
- Product Certifications: CE UL CSA CCC EAC ASEFA ATEX Marine
- Product Specific Application: Basic protection and advanced functions, communication
- Product compatibility: Power base LUB12 Power base LUB32 Power base LUB38 Power base LUB120 Power base LUB320 Power base LUB380 Reversing contactor breaker LU2B12BL Reversing contactor breaker LU2B32BL Reversing contactor breaker LU2B38BL
- Product or Component Type: Advanced control unit
- Range: TeSys
- Range of Product: TeSys Ultra
- Reset: Manual reset
- Safe separation of circuit: 400 V SELV between the control and auxiliary circuits IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
- Standards: EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier
- Thermal overload class: Class 20 40â¦60 Hz -13â¦158 °F (-25â¦70 °C) IEC 60947-6-2 Class 20 40â¦60 Hz -13â¦158 °F (-25â¦70 °C) UL 508
- Tripping threshold: 14.2 x Ir +/- 20 %
- Typical current consumption: 130 mA 24 V DC I maximum while closing with LUB12 220 mA 24 V DC I maximum while closing with LUB32 220 mA 24 V DC I maximum while closing with LUB38 60 mA 24 V DC I rms sealed with LUB12 80 mA 24 V DC I rms sealed with LUB32 80 mA 24 V DC I rms sealed with LUB38
- Utilisation category: AC-41 AC-43 AC-44
- Width: 1.8 in (45 mm)
- [Uc] control circuit voltage: 24 V DC
- [Ue] rated operational voltage: 690 V AC
- [Ui] rated insulation voltage: 690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1
- [Uimp] rated impulse withstand voltage: 6 kV IEC 60947-6-2
- main function available: Protection against phase failure and phase imbalance Manual reset Earth fault protection Protection against overload and short-circuit
- product name: TeSys Ultra
- rated motor current adjustment range: 0.15â¦0.6 A
Condition and supply
- Price on request: send an inquiry with the quantity you need
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number LUCDX6BL with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- LUCDX6BL
- Brand
- Schneider Electric
- Part Number
- LUCDX6BL
- Category
- Schneider Electric Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Depth
- 2.4 in (60 mm)
- Range
- TeSys
- Reset
- Manual reset
- Width
- 1.8 in (45 mm)
- Height
- 2.6 in (66 mm)
- Load type
- 3-phase motor self-cooled
- Standards
- EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier
- Fixing mode
- Plug-in (front face)
- product name
- TeSys Ultra
- Characteristic
- Value(s)
- Motor power kW
- 0.09 kW 400...440 V AC 50/60 Hz
- Operating time
- 35 ms opening with LUB12 control circuit 35 ms opening with LUB32 control circuit 35 ms opening with LUB38 control circuit 70 ms closing with LUB12 control circuit 70 ms closing with LUB32 control circuit 70 ms closing with LUB38 control circuit
- Heat dissipation
- 2 W control circuit with LUB12 3 W control circuit with LUB32 3 W control circuit with LUB38
- Range of Product
- TeSys Ultra
- Device short name
- LUCD
- Network frequency
- 40...60 Hz
- Compatibility code
- LUCD
- Device Application
- Motor control Motor protection
- Tripping threshold
- 14.2 x Ir +/- 20 %
- Utilisation category
- AC-41 AC-43 AC-44
- Product compatibility
- Power base LUB12 Power base LUB32 Power base LUB38 Power base LUB120 Power base LUB320 Power base LUB380 Reversing contactor breaker LU2B12BL Reversing contactor breaker LU2B32BL Reversing contactor breaker LU2B38BL
- Product Certifications
- CE UL CSA CCC EAC ASEFA ATEX Marine
- Thermal overload class
- Class 20 40â¦60 Hz -13â¦158 °F (-25â¦70 °C) IEC 60947-6-2 Class 20 40â¦60 Hz -13â¦158 °F (-25â¦70 °C) UL 508
- main function available
- Protection against phase failure and phase imbalance Manual reset Earth fault protection Protection against overload and short-circuit
- Phase failure sensitivity
- Yes
- Product or Component Type
- Advanced control unit
- Safe separation of circuit
- 400 V SELV between the control and auxiliary circuits IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
- Typical current consumption
- 130 mA 24 V DC I maximum while closing with LUB12 220 mA 24 V DC I maximum while closing with LUB32 220 mA 24 V DC I maximum while closing with LUB38 60 mA 24 V DC I rms sealed with LUB12 80 mA 24 V DC I rms sealed with LUB32 80 mA 24 V DC I rms sealed with LUB38
- Product Specific Application
- Basic protection and advanced functions, communication
- [Uc] control circuit voltage
- 24 V DC
- [Ui] rated insulation voltage
- 690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1
- Control circuit voltage limits
- 20...27 V DC 24 V in operation 14.5 V DC 24 V drop-out
- [Ue] rated operational voltage
- 690 V AC
- rated motor current adjustment range
- 0.15â¦0.6 A
- [Uimp] rated impulse withstand voltage
- 6 kV IEC 60947-6-2
Compatibility Information
Match LUCDX6BL against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the Schneider Electric documentation for the host system when replacing LUCDX6BL.
Maintenance Tips
Store LUCDX6BL dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. LUCDX6BL is in stock and ships within 1-2 business days, with a tracking number for every shipment.
LUCDX6BL is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match LUCDX6BL against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
Schneider Electric ZR2FA2
SKU: ZR2FA2
Schneider Electric ZMLPA2P0SH
SKU: ZMLPA2P0SH
Schneider Electric ZMLPA2N0SH
SKU: ZMLPA2N0SH
Schneider Electric ZMLPA1P2SW
SKU: ZMLPA1P2SW