+86 13348028050
LUCD18B Schneider Electric LUCD18B - Front View | Vcocnc FANUC Parts

Schneider Electric LUCD18B

Product information

SKU: LUCD18B

Alternate: LUCD18B

Brand
Schneider Electric
Part No.
LUCD18B
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LUCD18B Product overview The Schneider Electric LUCD18B is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Compatibility code: LUCD - Control circuit voltage limits: 20...26.5 V AC 24 V in operation 14.5 V AC 24 V drop-out - Depth: 2.4 in (60 mm) - Device Application: Motor control Motor protection - Device short name: LUCD - Fixing mode: Plug-in (front face) - Heat dissipation: 3 W control circuit with LUB32 3 W control circuit with LUB38 - Height: 2.6 in (66 mm) - Load type: 3-phase motor self-cooled - Motor power kW: 7.5 kW 400...440 V AC 50/60 Hz 9 kW 500 V AC 50/60 Hz 15 kW 690 V AC 50/60 Hz - Network frequency: 40...60 Hz - Operating time: 35 ms opening with LUB32 control circuit 35 ms opening with LUB38 control circuit 70 ms closing with LUB32 control circuit 70 ms closing with LUB38 control circuit - Phase failure sensitivity: Yes - Product Certifications: CE UL CSA CCC EAC ASEFA ATEX Marine - Product Specific Application: Basic protection and advanced functions, communication - Product compatibility: Power base LUB32 Power base LUB38 Power base LUB320 Power base LUB380 Reversing contactor breaker LU2B32B - Product or Component Type: Advanced control unit - Range: TeSys - Range of Product: TeSys U - Reset: Manual reset - Safe separation of circuit: 400 V SELV between the control and auxiliary circuits IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 - Standards: EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier - Thermal overload class: Class 20 40…60 Hz -13…158 °F (-25…70 °C) IEC 60947-6-2 Class 20 40…60 Hz -13…158 °F (-25…70 °C) UL 508 - Tripping threshold: 14.2 x Ir +/- 20 % - Typical current consumption: 220 mA 24 V AC I maximum while closing with LUB32 220 mA 24 V AC I maximum while closing with LUB38 90 mA 24 V AC I rms sealed with LUB32 90 mA 24 V AC I rms sealed with LUB38 - Utilisation category: AC-44 AC-43 AC-41 - Width: 1.8 in (45 mm) - [Uc] control circuit voltage: 24 V AC - [Ue] rated operational voltage: 690 V AC - [Ui] rated insulation voltage: 690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1 - [Uimp] rated impulse withstand voltage: 6 kV IEC 60947-6-2 - main function available: Protection against overload and short-circuit Protection against phase failure and phase imbalance Manual reset Earth fault protection - product name: TeSys U - rated motor current adjustment range: 4.5…18 A Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LUCD18B with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LUCD18B
Brand
Schneider Electric
Part Number
LUCD18B
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Depth
2.4 in (60 mm)
Range
TeSys
Reset
Manual reset
Width
1.8 in (45 mm)
Height
2.6 in (66 mm)
Load type
3-phase motor self-cooled
Standards
EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier
Fixing mode
Plug-in (front face)
product name
TeSys U
Characteristic
Value(s)
Motor power kW
7.5 kW 400...440 V AC 50/60 Hz 9 kW 500 V AC 50/60 Hz 15 kW 690 V AC 50/60 Hz
Operating time
35 ms opening with LUB32 control circuit 35 ms opening with LUB38 control circuit 70 ms closing with LUB32 control circuit 70 ms closing with LUB38 control circuit
Heat dissipation
3 W control circuit with LUB32 3 W control circuit with LUB38
Range of Product
TeSys U
Device short name
LUCD
Network frequency
40...60 Hz
Compatibility code
LUCD
Device Application
Motor control Motor protection
Tripping threshold
14.2 x Ir +/- 20 %
Utilisation category
AC-44 AC-43 AC-41
Product compatibility
Power base LUB32 Power base LUB38 Power base LUB320 Power base LUB380 Reversing contactor breaker LU2B32B
Product Certifications
CE UL CSA CCC EAC ASEFA ATEX Marine
Thermal overload class
Class 20 40…60 Hz -13…158 °F (-25…70 °C) IEC 60947-6-2 Class 20 40…60 Hz -13…158 °F (-25…70 °C) UL 508
main function available
Protection against overload and short-circuit Protection against phase failure and phase imbalance Manual reset Earth fault protection
Phase failure sensitivity
Yes
Product or Component Type
Advanced control unit
Safe separation of circuit
400 V SELV between the control and auxiliary circuits IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Typical current consumption
220 mA 24 V AC I maximum while closing with LUB32 220 mA 24 V AC I maximum while closing with LUB38 90 mA 24 V AC I rms sealed with LUB32 90 mA 24 V AC I rms sealed with LUB38
Product Specific Application
Basic protection and advanced functions, communication
[Uc] control circuit voltage
24 V AC
[Ui] rated insulation voltage
690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1
Control circuit voltage limits
20...26.5 V AC 24 V in operation 14.5 V AC 24 V drop-out
[Ue] rated operational voltage
690 V AC
rated motor current adjustment range
4.5…18 A
[Uimp] rated impulse withstand voltage
6 kV IEC 60947-6-2

Compatibility Information

Match LUCD18B against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LUCD18B.

Maintenance Tips

Store LUCD18B dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options