+86 13348028050
LUCBT1BL Schneider Electric LUCBT1BL - Front View | Vcocnc FANUC Parts

Schneider Electric LUCBT1BL

Product information

SKU: LUCBT1BL

Alternate: LUCBT1BL

Brand
Schneider Electric
Part No.
LUCBT1BL
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LUCBT1BL Product overview The Schneider Electric LUCBT1BL is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Compatibility code: LUCB - Control circuit voltage limits: 20...28 V for DC circuit 24 V in operation 14.5 V for DC circuit 24 V drop-out - Depth: 60 mm - Device application: Motor control Motor protection - Device short name: LUCB - Fixing mode: Plug-in (front face) - Heat dissipation: 2 W for control circuit - Height: 66 mm - Load type: 3-phase motor - cooling: self-cooled - Network frequency: 40...60 Hz - Operating time: 35 ms opening for control circuit 70 ms closing for control circuit - Phase failure sensitivity: Yes - Product certifications: UL CSA - Product compatibility: Power base LUTM - Product or component type: Advanced control unit - Product specific application: Basic protection and advanced functions, communication - Range: TeSys - Range of product: TeSys Ultra - Reset: Manual reset - Standards: EN 60947-6-2 IEC 60947-6-2 UL 508 CSA C22.2 No 14 - Thermal overload class: Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to IEC 60947-6-2 Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to UL 508 - Tripping threshold: 14.2 x Ir +/- 20 % - Typical current consumption: 130 mA at 24 V DC I maximum while closing 60 mA at 24 V DC I rms sealed - Utilisation category: AC-41 AC-44 AC-43 - Width: 45 mm - [Uc] control circuit voltage: 24 V DC - [Ui] rated insulation voltage: 250 V conforming to IEC 60947-6-2 250 V conforming to UL 60947-4-1 250 V conforming to CSA C22.2 No 60947-4-1 - [Uimp] rated impulse withstand voltage: 4 kV conforming to IEC 60947-6-2 - main function available: Protection against phase failure and phase imbalance Protection against overload and short-circuit Earth fault protection Manual reset - rated motor current adjustment range: 0.35…1.05 A Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LUCBT1BL with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LUCBT1BL
Brand
Schneider Electric
Part Number
LUCBT1BL
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Depth
60 mm
Range
TeSys
Reset
Manual reset
Width
45 mm
Height
66 mm
Load type
3-phase motor - cooling: self-cooled
Standards
EN 60947-6-2 IEC 60947-6-2 UL 508 CSA C22.2 No 14
Fixing mode
Plug-in (front face)
Characteristic
Value(s)
Operating time
35 ms opening for control circuit 70 ms closing for control circuit
Heat dissipation
2 W for control circuit
Range of product
TeSys Ultra
Device short name
LUCB
Network frequency
40...60 Hz
Compatibility code
LUCB
Device application
Motor control Motor protection
Tripping threshold
14.2 x Ir +/- 20 %
Utilisation category
AC-41 AC-44 AC-43
Product compatibility
Power base LUTM
Product certifications
UL CSA
Thermal overload class
Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to IEC 60947-6-2 Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to UL 508
main function available
Protection against phase failure and phase imbalance Protection against overload and short-circuit Earth fault protection Manual reset
Phase failure sensitivity
Yes
Product or component type
Advanced control unit
Typical current consumption
130 mA at 24 V DC I maximum while closing 60 mA at 24 V DC I rms sealed
Product specific application
Basic protection and advanced functions, communication
[Uc] control circuit voltage
24 V DC
[Ui] rated insulation voltage
250 V conforming to IEC 60947-6-2 250 V conforming to UL 60947-4-1 250 V conforming to CSA C22.2 No 60947-4-1
Control circuit voltage limits
20...28 V for DC circuit 24 V in operation 14.5 V for DC circuit 24 V drop-out
rated motor current adjustment range
0.35…1.05 A
[Uimp] rated impulse withstand voltage
4 kV conforming to IEC 60947-6-2

Compatibility Information

Match LUCBT1BL against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LUCBT1BL.

Maintenance Tips

Store LUCBT1BL dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.