Product information

SKU: LU2BB0FU

Alternate: LU2BB0FU

Brand
Schneider Electric
Part No.
LU2BB0FU
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LU2BB0FU Product overview The Schneider Electric LU2BB0FU is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Auxiliary contact composition: 1 NO + 1 NC - Auxiliary contacts type: type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 type mirror contact (1 NC) conforming to IEC 60947-1 - Characteristic: Value(s) - Compatibility code: LU2B - Connections - terminals: Power circuit: screw clamp terminals 1 cable(s) 1…10 mm² rigid Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² rigid Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable end Control circuit: without connection - Control circuit voltage limits: 55 V DC drop-out 55 V AC drop-out 88...242 V DC in operation 88...264 V AC in operation - Depth: 126 mm - Device application: Motor control Motor protection - Device short name: LU2B - Fixing mode: Clipped (DIN rail) Screw-fixed (plate) - Heat dissipation: 3 W for control circuit with LUCA, LUCB, LUCC, LUCD 1.8 W for control circuit with LUCM - Height: 224 mm - Inrush restraint duration: 25 ms AC 50/60 Hz 15 ms DC - Maximum operating rate: 3600 cyc/h - Mechanical durability: 15 Mcycles - Network frequency: 40...60 Hz - Operating time: 150 ms with change of direction for power circuit 35 ms opening for control circuit 75 ms without change of direction for power circuit 50 ms closing for control circuit - Poles description: 3P - Product certifications: CE UL CSA CCC EAC ASEFA ATEX Marine - Product compatibility: Control unit LUC.X6FU Control unit LUC.1XFU Control unit LUC.05FU Control unit LUC.12FU Control unit LUC.18FU Control unit LUC.32FU - Product or component type: Reversing power base - Product weight: 1.25 kg - Range: TeSys - Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N - Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 - Standards: EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier - Suitability for isolation: Yes - Tightening torque: Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm - Typical current consumption: 1000 mA at 110...220 V DC I maximum while closing 1000 mA at 110...240 V AC I maximum while closing - Utilisation category: AC-43 AC-44 AC-41 - Width: 45 mm - [Ics] rated service breaking capacity: 50 kA at 230 V 50 kA at 440 V 10 kA at 500 V 4 kA at 690 V - [Ie] rated operational current: 28.5 A at <= 440 V 23 A at 500 V 21 A at 690 V - [Ith] conventional free air thermal current: 32 A - [Uc] control circuit voltage: 110...240 V AC 50/60 Hz 110...220 V DC - [Ue] rated operational voltage: 690 V AC for power circuit - [Ui] rated insulation voltage: 690 V conforming to IEC 60947-6-2 (pollution degree 3) 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1 - [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2 - product name: TeSys U Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LU2BB0FU with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LU2BB0FU
Brand
Schneider Electric
Part Number
LU2BB0FU
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Depth
126 mm
Range
TeSys
Width
45 mm
Height
224 mm
Standards
EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier
Fixing mode
Clipped (DIN rail) Screw-fixed (plate)
product name
TeSys U
Characteristic
Value(s)
Operating time
150 ms with change of direction for power circuit 35 ms opening for control circuit 75 ms without change of direction for power circuit 50 ms closing for control circuit
Product weight
1.25 kg
Heat dissipation
3 W for control circuit with LUCA, LUCB, LUCC, LUCD 1.8 W for control circuit with LUCM
Device short name
LU2B
Network frequency
40...60 Hz
Poles description
3P
Tightening torque
Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm
Compatibility code
LU2B
Device application
Motor control Motor protection
Utilisation category
AC-43 AC-44 AC-41
Mechanical durability
15 Mcycles
Product compatibility
Control unit LUC.X6FU Control unit LUC.1XFU Control unit LUC.05FU Control unit LUC.12FU Control unit LUC.18FU Control unit LUC.32FU
Maximum operating rate
3600 cyc/h
Product certifications
CE UL CSA CCC EAC ASEFA ATEX Marine
Auxiliary contacts type
type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 type mirror contact (1 NC) conforming to IEC 60947-1
Connections - terminals
Power circuit: screw clamp terminals 1 cable(s) 1…10 mm² rigid Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² rigid Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable end Control circuit: without connection
Safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Inrush restraint duration
25 ms AC 50/60 Hz 15 ms DC
Product or component type
Reversing power base
Suitability for isolation
Yes
Safe separation of circuit
400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
Typical current consumption
1000 mA at 110...220 V DC I maximum while closing 1000 mA at 110...240 V AC I maximum while closing
[Uc] control circuit voltage
110...240 V AC 50/60 Hz 110...220 V DC
Auxiliary contact composition
1 NO + 1 NC
[Ui] rated insulation voltage
690 V conforming to IEC 60947-6-2 (pollution degree 3) 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1
Control circuit voltage limits
55 V DC drop-out 55 V AC drop-out 88...242 V DC in operation 88...264 V AC in operation
[Ie] rated operational current
28.5 A at <= 440 V 23 A at 500 V 21 A at 690 V
[Ue] rated operational voltage
690 V AC for power circuit
[Ics] rated service breaking capacity
50 kA at 230 V 50 kA at 440 V 10 kA at 500 V 4 kA at 690 V
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-6-2
[Ith] conventional free air thermal current
32 A

Compatibility Information

Match LU2BB0FU against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LU2BB0FU.

Maintenance Tips

Store LU2BB0FU dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options