Schneider Electric LU2BA0B
Product overview
The Schneider Electric LU2BA0B is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Auxiliary contact composition: 1 NO + 1 NC
- Auxiliary contacts type: type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 type mirror contact (1 NC) conforming to IEC 60947-1
- Characteristic: Value(s)
- Compatibility code: LU2B
- Connections - terminals: Power circuit: screw clamp terminals 1 cable(s) 1â¦10 mm² rigid Power circuit: screw clamp terminals 1 cable(s) 1â¦6 mm² flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 2.5â¦10 mm² flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1â¦6 mm² flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1â¦6 mm² rigid Power circuit: screw clamp terminals 2 cable(s) 1.5â¦6 mm² flexible without cable end Control circuit: without connection
- Control circuit voltage limits: 14.5 V AC drop-out 20...26.5 V AC in operation
- Depth: 126 mm
- Device application: Motor control Motor protection
- Device short name: LU2B
- Fixing mode: Clipped (DIN rail) Screw-fixed (plate)
- Heat dissipation: 2 W for control circuit with LUCA, LUCB, LUCC, LUCD 1.7 W for control circuit with LUCM
- Height: 224 mm
- Inrush restraint duration: 25 ms AC 50/60 Hz
- Maximum operating rate: 3600 cyc/h
- Mechanical durability: 15 Mcycles
- Network frequency: 40...60 Hz
- Operating time: 150 ms with change of direction for power circuit 75 ms without change of direction for power circuit 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit 50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit 60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit 70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit 75 ms closing with LUCM for control circuit
- Poles description: 3P
- Product certifications: CE UL CSA CCC EAC ASEFA ATEX Marine
- Product compatibility: Control unit LUC.X6B Control unit LUC.1XB Control unit LUC.05B Control unit LUC.12B
- Product or component type: Reversing power base
- Product weight: 1.27 kg
- Range: TeSys
- Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
- Standards: EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier
- Suitability for isolation: Yes
- Tightening torque: Power circuit: 1.9â¦2.5 N.m flat screwdriver 6 mm Power circuit: 1.9â¦2.5 N.m Philips No 2 screwdriver 6 mm
- Typical current consumption: 2360 mA at 24 V AC I maximum while closing
- Utilisation category: AC-43 AC-44 AC-41
- Width: 45 mm
- [Ics] rated service breaking capacity: 50 kA at 230 V 50 kA at 440 V 10 kA at 500 V 4 kA at 690 V
- [Ie] rated operational current: 12 A at <= 440 V 12 A at 500 V 9 A at 690 V
- [Ith] conventional free air thermal current: 12 A
- [Uc] control circuit voltage: 24 V AC 50/60 Hz
- [Ue] rated operational voltage: 690 V AC for power circuit
- [Ui] rated insulation voltage: 690 V conforming to IEC 60947-6-2 (pollution degree 3) 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2
- product name: TeSys U
Condition and supply
- Price on request: send an inquiry with the quantity you need
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number LU2BA0B with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- LU2BA0B
- Brand
- Schneider Electric
- Part Number
- LU2BA0B
- Category
- Schneider Electric Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Depth
- 126 mm
- Range
- TeSys
- Width
- 45 mm
- Height
- 224 mm
- Standards
- EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier
- Fixing mode
- Clipped (DIN rail) Screw-fixed (plate)
- product name
- TeSys U
- Characteristic
- Value(s)
- Operating time
- 150 ms with change of direction for power circuit 75 ms without change of direction for power circuit 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit 50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit 60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit 70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit 75 ms closing with LUCM for control circuit
- Product weight
- 1.27 kg
- Heat dissipation
- 2 W for control circuit with LUCA, LUCB, LUCC, LUCD 1.7 W for control circuit with LUCM
- Device short name
- LU2B
- Network frequency
- 40...60 Hz
- Poles description
- 3P
- Tightening torque
- Power circuit: 1.9â¦2.5 N.m flat screwdriver 6 mm Power circuit: 1.9â¦2.5 N.m Philips No 2 screwdriver 6 mm
- Compatibility code
- LU2B
- Device application
- Motor control Motor protection
- Utilisation category
- AC-43 AC-44 AC-41
- Mechanical durability
- 15 Mcycles
- Product compatibility
- Control unit LUC.X6B Control unit LUC.1XB Control unit LUC.05B Control unit LUC.12B
- Maximum operating rate
- 3600 cyc/h
- Product certifications
- CE UL CSA CCC EAC ASEFA ATEX Marine
- Auxiliary contacts type
- type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 type mirror contact (1 NC) conforming to IEC 60947-1
- Connections - terminals
- Power circuit: screw clamp terminals 1 cable(s) 1â¦10 mm² rigid Power circuit: screw clamp terminals 1 cable(s) 1â¦6 mm² flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 2.5â¦10 mm² flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1â¦6 mm² flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1â¦6 mm² rigid Power circuit: screw clamp terminals 2 cable(s) 1.5â¦6 mm² flexible without cable end Control circuit: without connection
- Safety reliability level
- B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
- Inrush restraint duration
- 25 ms AC 50/60 Hz
- Product or component type
- Reversing power base
- Suitability for isolation
- Yes
- Safe separation of circuit
- 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
- Typical current consumption
- 2360 mA at 24 V AC I maximum while closing
- [Uc] control circuit voltage
- 24 V AC 50/60 Hz
- Auxiliary contact composition
- 1 NO + 1 NC
- [Ui] rated insulation voltage
- 690 V conforming to IEC 60947-6-2 (pollution degree 3) 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1
- Control circuit voltage limits
- 14.5 V AC drop-out 20...26.5 V AC in operation
- [Ie] rated operational current
- 12 A at <= 440 V 12 A at 500 V 9 A at 690 V
- [Ue] rated operational voltage
- 690 V AC for power circuit
- [Ics] rated service breaking capacity
- 50 kA at 230 V 50 kA at 440 V 10 kA at 500 V 4 kA at 690 V
- [Uimp] rated impulse withstand voltage
- 6 kV conforming to IEC 60947-6-2
- [Ith] conventional free air thermal current
- 12 A
Compatibility Information
Match LU2BA0B against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the Schneider Electric documentation for the host system when replacing LU2BA0B.
Maintenance Tips
Store LU2BA0B dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. LU2BA0B is in stock and ships within 1-2 business days, with a tracking number for every shipment.
LU2BA0B is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match LU2BA0B against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
Schneider Electric ZR2FA2
SKU: ZR2FA2
Schneider Electric ZMLPA2P0SH
SKU: ZMLPA2P0SH
Schneider Electric ZMLPA2N0SH
SKU: ZMLPA2N0SH
Schneider Electric ZMLPA1P2SW
SKU: ZMLPA1P2SW