+86 13348028050
LU2B12B Schneider Electric LU2B12B - Front View | Vcocnc FANUC Parts

Schneider Electric LU2B12B

Product information

$1,265.60 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: LU2B12B

Alternate: LU2B12B

Brand
Schneider Electric
Part No.
LU2B12B
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LU2B12B Product overview The Schneider Electric LU2B12B is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Auxiliary contact composition: 1 NO + 1 NC - Auxiliary contacts type: Linked contacts 1 NO + 1 NC) IEC 60947-4-1 Mirror contact 1 NC) IEC 60947-1 - Characteristic: Value(s) - Compatibility code: LU2B - Connections - terminals: Control circuit screw clamp terminals 1 0.0005…0.002 in² (0.34…1.5 mm²) flexible with cable end Control circuit screw clamp terminals 1 0.001…0.002 in² (0.75…1.5 mm²) flexible without cable end Control circuit screw clamp terminals 1 0.001…0.002 in² (0.75…1.5 mm²) rigid Control circuit screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²) flexible with cable end Control circuit screw clamp terminals 2 0.001…0.002 in² (0.75…1.5 mm²) flexible without cable end Control circuit screw clamp terminals 2 0.001…0.002 in² (0.75…1.5 mm²) rigid Power circuit screw clamp terminals 1 0.002…0.02 in² (1…10 mm²) rigid Power circuit screw clamp terminals 1 0.002…0.009 in² (1…6 mm²) flexible with cable end Power circuit screw clamp terminals 1 0.004…0.02 in² (2.5…10 mm²) flexible without cable end Power circuit screw clamp terminals 2 0.002…0.009 in² (1…6 mm²) flexible with cable end Power circuit screw clamp terminals 2 0.002…0.009 in² (1…6 mm²) rigid Power circuit screw clamp terminals 2 0.002…0.009 in² (1.5…6 mm²) flexible without cable end - Control circuit voltage limits: 14.5 V AC drop-out 20...26.5 V AC in operation - Depth: 5.0 in (126 mm) - Device Application: Motor control Motor protection - Device short name: LU2B - Fixing mode: Clipped (DIN rail) Screw-fixed (plate) - Heat dissipation: 2 W control circuit with LUCA, LUCB, LUCC, LUCD 1.7 W control circuit with LUCM - Height: 8.8 in (224 mm) - Inrush restraint duration: 25 ms AC 50/60 Hz - Maximum operating rate: 3600 cyc/h - Mechanical durability: 15 Mcycles - Network frequency: 40...60 Hz - Operating time: 150 ms with change of direction power circuit 35 ms opening control circuit 70 ms closing control circuit 75 ms without change of direction power circuit - Poles description: 3P - Product Certifications: CE UL CSA CCC EAC ASEFA ATEX Marine - Product Weight: 2.80 lb(US) (1.27 kg) - Product compatibility: Control unit LUC.X6B Control unit LUC.1XB Control unit LUC.05B Control unit LUC.12B - Product or Component Type: Reversing power base - Range: TeSys - Safe separation of circuit: 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N - Safety reliability level: B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 - Standards: EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier - Suitability for isolation: Yes - Tightening torque: Control circuit: 7.08…10.6 lbf.in (0.8…1.2 N.m) flat screwdriver 0.2 in (5 mm) Control circuit: 7.08…10.6 lbf.in (0.8…1.2 N.m) Philips no 1 screwdriver 0.2 in (5 mm) Power circuit: 16.8…22.1 lbf.in (1.9…2.5 N.m) flat screwdriver 0.2 in (6 mm) Power circuit: 16.8…22.1 lbf.in (1.9…2.5 N.m) Philips No 2 screwdriver 0.2 in (6 mm) Power circuit: 16.8…22.1 lbf.in (1.9…2.5 N.m) pozidriv No 2 screwdriver 0.2 in (6 mm) - Typical current consumption: 2360 mA 24 V AC I maximum while closing - Utilisation category: AC-43 AC-44 AC-41 - Width: 1.8 in (45 mm) - [Ics] rated service breaking capacity: 50 kA 230 V 50 kA 440 V 10 kA 500 V 4 kA 690 V - [Ie] rated operational current: 12 A <= 440 V 12 A 500 V 9 A 690 V - [Ith] conventional free air thermal current: 12 A - [Uc] control circuit voltage: 24 V AC 50/60 Hz - [Ue] rated operational voltage: 690 V AC power circuit - [Ui] rated insulation voltage: 690 V IEC 60947-6-2 3) 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1 - [Uimp] rated impulse withstand voltage: 6 kVIEC 60947-6-2 - product name: TeSys Ultra Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LU2B12B with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LU2B12B
Brand
Schneider Electric
Part Number
LU2B12B
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Depth
5.0 in (126 mm)
Range
TeSys
Width
1.8 in (45 mm)
Height
8.8 in (224 mm)
Packaging
New surplus, never used
Standards
EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier
Fixing mode
Clipped (DIN rail) Screw-fixed (plate)
product name
TeSys Ultra
Characteristic
Value(s)
Operating time
150 ms with change of direction power circuit 35 ms opening control circuit 70 ms closing control circuit 75 ms without change of direction power circuit
Product Weight
2.80 lb(US) (1.27 kg)
Heat dissipation
2 W control circuit with LUCA, LUCB, LUCC, LUCD 1.7 W control circuit with LUCM
Device short name
LU2B
Network frequency
40...60 Hz
Poles description
3P
Tightening torque
Control circuit: 7.08…10.6 lbf.in (0.8…1.2 N.m) flat screwdriver 0.2 in (5 mm) Control circuit: 7.08…10.6 lbf.in (0.8…1.2 N.m) Philips no 1 screwdriver 0.2 in (5 mm) Power circuit: 16.8…22.1 lbf.in (1.9…2.5 N.m) flat screwdriver 0.2 in (6 mm) Power circuit: 16.8…22.1 lbf.in (1.9…2.5 N.m) Philips No 2 screwdriver 0.2 in (6 mm) Power circuit: 16.8…22.1 lbf.in (1.9…2.5 N.m) pozidriv No 2 screwdriver 0.2 in (6 mm)
Compatibility code
LU2B
Device Application
Motor control Motor protection
Utilisation category
AC-43 AC-44 AC-41
Mechanical durability
15 Mcycles
Product compatibility
Control unit LUC.X6B Control unit LUC.1XB Control unit LUC.05B Control unit LUC.12B
Maximum operating rate
3600 cyc/h
Product Certifications
CE UL CSA CCC EAC ASEFA ATEX Marine
Auxiliary contacts type
Linked contacts 1 NO + 1 NC) IEC 60947-4-1 Mirror contact 1 NC) IEC 60947-1
Connections - terminals
Control circuit screw clamp terminals 1 0.0005…0.002 in² (0.34…1.5 mm²) flexible with cable end Control circuit screw clamp terminals 1 0.001…0.002 in² (0.75…1.5 mm²) flexible without cable end Control circuit screw clamp terminals 1 0.001…0.002 in² (0.75…1.5 mm²) rigid Control circuit screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²) flexible with cable end Control circuit screw clamp terminals 2 0.001…0.002 in² (0.75…1.5 mm²) flexible without cable end Control circuit screw clamp terminals 2 0.001…0.002 in² (0.75…1.5 mm²) rigid Power circuit screw clamp terminals 1 0.002…0.02 in² (1…10 mm²) rigid Power circuit screw clamp terminals 1 0.002…0.009 in² (1…6 mm²) flexible with cable end Power circuit screw clamp terminals 1 0.004…0.02 in² (2.5…10 mm²) flexible without cable end Power circuit screw clamp terminals 2 0.002…0.009 in² (1…6 mm²) flexible with cable end Power circuit screw clamp terminals 2 0.002…0.009 in² (1…6 mm²) rigid Power circuit screw clamp terminals 2 0.002…0.009 in² (1.5…6 mm²) flexible without cable end
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Inrush restraint duration
25 ms AC 50/60 Hz
Product or Component Type
Reversing power base
Suitability for isolation
Yes
Safe separation of circuit
400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
Typical current consumption
2360 mA 24 V AC I maximum while closing
[Uc] control circuit voltage
24 V AC 50/60 Hz
Auxiliary contact composition
1 NO + 1 NC
[Ui] rated insulation voltage
690 V IEC 60947-6-2 3) 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1
Control circuit voltage limits
14.5 V AC drop-out 20...26.5 V AC in operation
[Ie] rated operational current
12 A <= 440 V 12 A 500 V 9 A 690 V
[Ue] rated operational voltage
690 V AC power circuit
[Ics] rated service breaking capacity
50 kA 230 V 50 kA 440 V 10 kA 500 V 4 kA 690 V
[Uimp] rated impulse withstand voltage
6 kVIEC 60947-6-2
[Ith] conventional free air thermal current
12 A

Compatibility Information

Match LU2B12B against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LU2B12B.

Maintenance Tips

Store LU2B12B dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options